THE EFFECT OF COLUMN CHARACTERISTICS ON THE MINIMUM ANALYTE CONCENTRATION AND THE MINIMUM DETECTABLE AMOUNT IN CAPILLARY GAS-CHROMATOGRAPHY .2. THE STATIONARY PHASE FILM THICKNESS

被引:5
|
作者
NOY, T [1 ]
CRAMERS, C [1 ]
机构
[1] EINDHOVEN UNIV TECHNOL,DEPT CHEM ENGN,INSTRUMENTAL ANAL LAB,POB 513,5600 MB EINDHOVEN,NETHERLANDS
来源
JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS | 1988年 / 11卷 / 03期
关键词
D O I
10.1002/jhrc.1240110309
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
引用
收藏
页码:264 / 270
页数:7
相关论文
共 47 条
  • [1] THE EFFECT OF COLUMN CHARACTERISTICS ON THE MINIMUM ANALYTE CONCENTRATION AND THE MINIMUM DETECTABLE AMOUNT IN CAPILLARY GAS-CHROMATOGRAPHY
    NOY, T
    CURVERS, J
    CRAMERS, CA
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1986, 9 (12): : 752 - 759
  • [2] FILM THICKNESS REQUIRED OF THE STATIONARY PHASE IN THE SEPARATION COLUMN WHEN USING LARGE RETENTION GAPS IN CAPILLARY GAS-CHROMATOGRAPHY
    GROB, K
    JOURNAL OF CHROMATOGRAPHY, 1985, 328 (JUN): : 55 - 61
  • [3] POLARIZABLE BIPHENYL POLYSILOXANE STATIONARY PHASE FOR CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    KUEI, JC
    SHELTON, JI
    CASTLE, LW
    KONG, RC
    RICHTER, BE
    BRADSHAW, JS
    LEE, ML
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (01): : 13 - 18
  • [4] MEASUREMENT OF AVERAGE THICKNESS OF FILM OF STATIONARY PHASE IN DYNAMICALLY COATED GLASS CAPILLARY COLUMNS FOR GAS-CHROMATOGRAPHY
    BLOMBERG, L
    JOURNAL OF CHROMATOGRAPHY, 1977, 138 (01): : 7 - 16
  • [5] PREPARATION AND CHARACTERISTICS OF A BONDED PHASE GLASS CAPILLARY COLUMN FOR GAS-CHROMATOGRAPHY
    EINIG, RG
    MACDONALD, JL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1975, (169): : 99 - 99
  • [6] PREPARATION AND CHARACTERISTICS OF A CROWN ETHER POLYSILOXANE STATIONARY PHASE FOR CAPILLARY GAS-CHROMATOGRAPHY
    WU, CY
    WANG, CM
    ZENG, ZR
    LU, XR
    ANALYTICAL CHEMISTRY, 1990, 62 (09) : 968 - 971
  • [7] EFFECT OF STATIONARY PHASE FILM THICKNESS ON EFFICIENCY IN CAPILLARY SUPERCRITICAL FLUID CHROMATOGRAPHY
    FIELDS, SM
    KONG, RC
    LEE, ML
    PEADEN, PA
    JOURNAL OF HIGH RESOLUTION CHROMATOGRAPHY & CHROMATOGRAPHY COMMUNICATIONS, 1984, 7 (07): : 423 - 428
  • [8] PARA-AZOXYANISOLE LIQUID-CRYSTAL AS A STATIONARY PHASE FOR CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    GRUSHKA, E
    SOLSKY, JF
    ANALYTICAL CHEMISTRY, 1973, 45 (11) : 1836 - 1841
  • [9] PREPARATIVE CAPILLARY GAS-CHROMATOGRAPHY .2. FRACTION COLLECTION ON TRAPS COATED WITH A VERY THICK-FILM OF IMMOBILIZED STATIONARY PHASE
    BLOMBERG, S
    ROERAADE, J
    JOURNAL OF CHROMATOGRAPHY, 1987, 394 (03): : 443 - 453
  • [10] USE OF POLY(SILARYLENE METHYLPHENYLSILOXANE) BLOCK COPOLYMER AS A THERMOSTABLE STATIONARY PHASE IN CAPILLARY COLUMN GAS-CHROMATOGRAPHY
    BUIJTEN, J
    BLOMBERG, L
    HOFFMANN, S
    MARKIDES, K
    WANNMAN, T
    JOURNAL OF CHROMATOGRAPHY, 1984, 301 (01): : 265 - 269