EVALUATION OF 85-PERCENT PREDICTED MAXIMAL HEART-RATE AS AN END-POINT FOR DIAGNOSTIC EXERCISE TESTING

被引:2
|
作者
COPLAN, NL [1 ]
GLEIM, GW [1 ]
STACHENFELD, N [1 ]
ESKENAZI, M [1 ]
MORALES, M [1 ]
NICHOLAS, JA [1 ]
机构
[1] LENOX HILL HOSP,DEPT MED,CARDIOL SECT,NEW YORK,NY 10021
关键词
D O I
10.1016/0002-8703(91)90307-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
[No abstract available]
引用
收藏
页码:1790 / 1791
页数:2
相关论文
共 22 条
  • [1] TREADMILL VS ARM EXERCISE - COMPARISON OF RATE PRESSURE PRODUCT AT 85-PERCENT PREDICTED MAXIMAL HEART-RATE
    COPLAN, NL
    GLEIM, GW
    SCANDURA, M
    NICHOLAS, JA
    CLINICAL RESEARCH, 1987, 35 (03): : A270 - A270
  • [2] COMPARISON OF ARM AND TREADMILL EXERCISE AT 85-PERCENT PREDICTED MAXIMUM HEART-RATE
    COPLAN, NL
    GLEIM, GW
    SCANDURA, M
    NICHOLAS, JA
    CLINICAL CARDIOLOGY, 1987, 10 (11) : 655 - 657
  • [3] 85% of maximal age-predicted heart rate is not a valid endpoint for exercise treadmill testing
    Mohit Jain
    Chileshe Nkonde
    Ben A. Lin
    Alerice Walker
    Frans J. Th. Wackers
    Journal of Nuclear Cardiology, 2011, 18 : 1026 - 1035
  • [4] 85% of maximal age-predicted heart rate is not a valid endpoint for exercise treadmill testing
    Jain, Mohit
    Nkonde, Chileshe
    Lin, Ben A.
    Walker, Alerice
    Wackers, Frans J. Th.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2011, 18 (06) : 1026 - 1035
  • [5] Predicted maximal heart rate for upper body exercise testing
    Hill, M.
    Talbot, C.
    Price, M.
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2016, 36 (02) : 155 - 158
  • [6] Another conclusion on "85% of maximal age-predicted heart rate is not a valid endpoint for exercise treadmill testing"
    Gholamrezanezhad, Ali
    Mirpour, Sahar
    Jazayeri-Moghadass, Behnam S.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 630 - 631
  • [7] Achievement of 85% of Maximal Age Predicted Heart Rate Is Not an Appropriate Exercise Stress End Point and May Result in Underestimation of Inducible ECG Ischemia
    Jain, Mohit
    Lin, Ben A.
    Walker, Alerice
    Wackers, Frans J.
    CIRCULATION, 2010, 122 (21)
  • [8] Another conclusion on “85% of maximal age-predicted heart rate is not a valid endpoint for exercise treadmill testing”
    Ali Gholamrezanezhad
    Sahar Mirpour
    Behnam S. Jazayeri-Moghadass
    Journal of Nuclear Cardiology, 2012, 19 : 630 - 631
  • [9] Should 85% of maximal predicted heart rate be used as an end point during dobutamine-atropine stress echocardiography?
    Robin, C
    Dehant, P
    Bogino, E
    Chauvel, C
    CIRCULATION, 2000, 102 (18) : 382 - 382
  • [10] Another conclusion on "85% of maximal age-predicted heart rate is not a valid endpoint for exercise treadmill testing" Response
    Wackers, Frans J. Th.
    Jain, Mohit
    JOURNAL OF NUCLEAR CARDIOLOGY, 2012, 19 (03) : 632 - 632