DETERMINATION OF CICLETANINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING

被引:2
|
作者
ANTONIEWICZ, SM [1 ]
COOK, JA [1 ]
BROWN, RR [1 ]
机构
[1] PARKE DAVIS RES CTR,DEPT PHARMACOKINET DRUG METAB,ANN ARBOR,MI 48106
来源
关键词
D O I
10.1016/0378-4347(92)80479-A
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The automated determination of cicletanine in human plasma by column-switching high-performance liquid chromatography with fluorescence detection is described. A linear response was observed for the plasma calibration curve in the range 0.05-10-mu-g base/ml. The minimum quantifiable level of the assay was 0.05-mu-g base/ml plasma. The extraction efficiency was approximately 98% for both cicletanine and the internal standard. Precision (coefficient of variation) ranged from 0.9 to 6.3% and the accuracy ranged from -8.5 to 5.3%. Freezing samples up to three months had no apparent effect on sample integrity. The method has been used to analyze rat and dog plasma samples from toxicology studies as well as human plasma from phase I and II clinical trials. This method has several advantages over previously published methods including reduced sample volume requirement and minimal sample preparation.
引用
收藏
页码:93 / 98
页数:6
相关论文
共 50 条
  • [1] AUTOMATED-DETERMINATION OF MIDAZOLAM IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING
    LAUBER, R
    MOSIMANN, M
    BUHRER, M
    ZBINDEN, AM
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 654 (01): : 69 - 75
  • [2] DETERMINATION OF RETINOIDS IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AND AUTOMATED COLUMN-SWITCHING
    WYSS, R
    METHODS IN ENZYMOLOGY, 1990, 189 : 146 - 155
  • [3] MICROMETHOD FOR THE DETERMINATION OF CEFPIRAMIDE IN HUMAN-PLASMA AND URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    DEMOTESMAINARD, F
    VINCON, G
    JARRY, C
    NECCIARI, J
    ALBIN, H
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 419 : 388 - 395
  • [4] ANALYSIS OF RIBOXAMIDE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    RILEY, CM
    STERNSON, LA
    REPTA, AJ
    JOURNAL OF CHROMATOGRAPHY, 1983, 276 (01): : 93 - 102
  • [5] AUTOMATED-DETERMINATION OF FLUVOXAMINE IN PLASMA BY COLUMN-SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    HARTTER, S
    WETZEL, H
    HIEMKE, C
    CLINICAL CHEMISTRY, 1992, 38 (10) : 2082 - 2086
  • [6] DETERMINATION OF CEFODIZIME IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    BOMPADRE, S
    FERRANTE, L
    LEONE, L
    DEMARTINIS, M
    GINALDI, L
    QUAGLINO, D
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1995, 18 (14): : 2895 - 2909
  • [7] DETERMINATION OF METOPROLOL IN HUMAN-PLASMA BY COLUMN SWITCHING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    LECAILLON, JB
    SOUPPART, C
    ABADIE, F
    CHROMATOGRAPHIA, 1982, 16 : 158 - 161
  • [8] DETERMINATION OF ALFUZOSIN IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH COLUMN-SWITCHING
    CARLUCCI, G
    DIGIUSEPPE, E
    MAZZEO, P
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1994, 17 (18): : 3989 - 3997
  • [9] DETERMINATION OF NIFEDIPINE IN HUMAN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING COLUMN-SWITCHING TECHNIQUE
    HORVAI, G
    HRABECZYPALL, A
    HORVATH, V
    KLEBOVICH, I
    MIKROCHIMICA ACTA, 1994, 113 (3-6) : 171 - 178
  • [10] DETERMINATION OF AN ALDOSTERONE ANTAGONIST IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY USING AUTOMATED COLUMN SWITCHING
    TIMM, U
    SANER, A
    JOURNAL OF CHROMATOGRAPHY, 1986, 378 (01): : 25 - 34