NONINVASIVE ASSESSMENT OF NO-REFLOW PHENOMENON IN A CANINE MODEL OF REPERFUSED INFARCTION BY CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING

被引:18
|
作者
CANET, E
REVEL, D
SEBBAG, L
DELORGERIL, M
BALDY, C
DELABRE, C
AMIEL, M
机构
[1] HOP CARDIOVASC & PNEUMOL,INSERM,U63,LYON,FRANCE
[2] HOP CARDIOVASC & PNEUMOL,EXPTL RADIOL LAB,CNRS,URA 1216,LYON,FRANCE
关键词
D O I
10.1016/0002-8703(95)90193-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to test whether contrast-enhanced magnetic resonance (MR) imaging may assess in vivo the severity of the no-reflow phenomenon in a dog model of infarction with 2-hour coronary occlusion followed by reperfusion (6 hours). Subsecond MR imaging combined with intravenous bolus administration of superparamagnetic iron oxide particles (SPIO) was performed at the fifth hour of reperfusion. An MR index was calculated using the difference of signal-intensity enhancement between ischemic and nonischemic zones during the SPIO first pass. Dogs were separated into two groups according to the severity of ischemia: collateral blood flow in the central ischemic zone at 120 minutes of occlusion (radioactive microsphere technique) <22.5% of the flow in the nonischemic zone (group I) or >22.5% (group II). Mean collateral blood flow during occlusion was lower in group I (11.3% +/- 2.9%, n = 7) than in group II (66.8% +/- 19.8%, n = 6, p < 0.05). Mean infarct size was significantly larger in group I (58.6% +/- 4.9% of the area-at-risk, n = 7) than in group II (16.5% +/- 6.5%, n = 6, p < 0.05). For the entire population (n = 13), the infarct size was inversely correlated to the collateral blood flow (r = -0.64, p = 0.02, standard error of estimate = 0.24). The relative rate of enhancement in ischemic myocardium (MR index) was significantly lower in group I (38.1% +/- 10.9%) than in group II (142.8% +/- 32%; p < 0.05). In addition, there was an inverse relation between the MR index and the infarct size (n = 13, r = -0.69, standard error of estimate = 0.07, p = 0.009). In conclusion, these data suggest that ultrafast MR images with intravenous bolus administration of SPIO during reperfusion is a valuable new method to assess the no-reflow phenomenon in a dog model of myocardial infarction.
引用
收藏
页码:949 / 956
页数:8
相关论文
共 50 条
  • [1] Impact of no-reflow and infarct size on left ventricular remodelling in reperfused myocardial infarction: study by contrast-enhanced magnetic resonance imaging
    Lombardo, A.
    Natale, L.
    Garramone, B.
    Lanza, G. A.
    Porcelli, A.
    Galiuto, L.
    Gabrielli, F. A.
    Crea, F.
    EUROPEAN HEART JOURNAL, 2005, 26 : 333 - 333
  • [2] Microvascular injury in reperfused infarcted myocardium: Noninvasive assessment with contrast-enhanced echoplanar magnetic resonance imaging
    Bremerich, J
    Wendland, MF
    Arheden, H
    Wyttenbach, R
    Gao, DW
    Huberty, JP
    Dae, MW
    Higgins, CB
    Saeed, H
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 32 (03) : 787 - 793
  • [3] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE BREAST
    GRIBBESTAD, IS
    NILSEN, G
    FJOSNE, H
    FOUGNER, R
    HAUGEN, OA
    PETERSEN, SB
    RINCK, PA
    KVINNSLAND, S
    ACTA ONCOLOGICA, 1992, 31 (08) : 833 - 842
  • [4] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE ABDOMEN
    BROWN, ED
    SEMELKA, RC
    MAGNETIC RESONANCE QUARTERLY, 1994, 10 (02) : 97 - 124
  • [5] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF THE BREAST
    HEYWANGKOBRUNNER, SH
    INVESTIGATIVE RADIOLOGY, 1994, 29 (01) : 94 - 104
  • [6] THE INDETERMINATE BREAST MASS - ASSESSMENT CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING
    HICKMAN, PF
    MOORE, NR
    SHEPSTONE, BJ
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (793): : 14 - 20
  • [7] INFARCT EXTENT AND PRESENCE OF NO-REFLOW REGIONS BY CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING PREDICT LONG-TERM PROGNOSIS AFTER ACUTE MYOCARDIAL-INFARCTION
    LIMA, JAC
    WU, KC
    JUDD, RM
    LUGOOLIVIERI, C
    SCHULMAN, SP
    BLUMENTHAL, RS
    ZERHOUNI, EA
    CIRCULATION, 1995, 92 (08) : 2429 - 2429
  • [8] CONTRAST-ENHANCED MAGNETIC-RESONANCE-IMAGING OF HYPOPERFUSED MYOCARDIUM
    SCHAEFER, S
    LANGE, RA
    GUTEKUNST, DP
    PARKEY, RW
    WILLERSON, JT
    PESHOCK, RM
    INVESTIGATIVE RADIOLOGY, 1991, 26 (06) : 551 - 556
  • [9] Contrast-enhanced magnetic resonance imaging in the assessment of myocardial infarction and viability
    Saraste, Antti
    Nekolla, Stephan
    Schwaiger, Markus
    JOURNAL OF NUCLEAR CARDIOLOGY, 2008, 15 (01) : 105 - 117
  • [10] Assessment of right ventricular infarction with contrast-enhanced magnetic resonance imaging
    Kaandorp, Theodorus A. M.
    Lamb, Hildo J.
    Poldermans, Don
    Viergever, Eric P.
    Boersma, Eric
    van der Wal, Ernst E.
    de Roos, Albert
    Bax, Jeroen J.
    CORONARY ARTERY DISEASE, 2007, 18 (01) : 39 - 43