Determination of Chlorhexidine Acetate in Chlorhexidine Acetate Suppositories by High Performance Liquid Chromatography Coupled with Hollow Fiber Membrane Solvent Microextraction

被引:0
|
作者
Fu Huafeng [1 ]
Guan Jiyu [1 ]
Qu Zhishuang [1 ]
Bao Jianmin [1 ]
机构
[1] Tianjin Univ, Coll Pharmaceut Sci & Biotechnol, Tianjin 300072, Peoples R China
关键词
hollow fiber membrane solvent microextraction; high performance liquid chromatography HPLC; chlorhexidine acetate; chlorhexidine acetate suppositories;
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method was developed to determine the content of chlorhexidine acetate CA in chlorhexidine acetate suppositories by high performance liquid chromatography HPLC coupled with hollow fiber membrane solvent microextraction. The sample was extracted with 1. 5 mol/L acetic acid solution five times then a hollow fiber containing n-octanol was placed in the sample solution to perform microextraction for extracting 20 min. The extract was analyzed by HPLC with UV detection at 260 nm. The chromatographic conditions were as following acetonitrile-redistilled water 29: 71 v/v containing 0. 3% triethylamine pH 3. 0 as mobile phase with the flow rate of 1 mL/min. The calibration curve of CA was linear from 0. 5 to 16 mg/L. The method recovery was over 98. 0% with relative standard deviation less than 4. 0%. By using hollow fiber membrane solvent microextraction the enrichment of 24-fold was achieved. The method is specific simple fast sensitive and suitable for the determination of chlorhexidine acetate.
引用
收藏
页码:566 / 569
页数:4
相关论文
共 50 条
  • [1] Determination of 4 phenols in water by three phase hollow fiber microextraction coupled with high performance liquid chromatography
    Wei Chao
    Lu Hengjun
    Chen Meilan
    Zhu Yan
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (01) : 54 - 58
  • [2] HOLLOW FIBER/SOLVENT BAR MICROEXTRACTION COUPLED WITH HIGH PERFORMANCE LIQUID CHROMATOGRAPHY FOR PRECONCENTRATION AND DETERMINATION OF TANSHINONES AND SALVIANOLIC ACIDS IN RADIX SALVIA MILTIORRHIZA
    Ma, Wenyan
    Chen, Xuan
    Hu, Shuang
    Bai, Xiaohong
    Li, QingShan
    ANALYTICAL LETTERS, 2014, 47 (02) : 220 - 233
  • [3] Determination of diuretics in human urine by hollow fiber-based liquid-liquid-liquid microextraction coupled to high performance liquid chromatography
    Zhang, Zhuomin
    Wang, Dapeng
    Zhang, Lan
    Du, Min
    Chen, Guonan
    ANALYST, 2008, 133 (09) : 1187 - 1194
  • [4] DETERMINATION OF CHLORHEXIDINE IN TOOTH PASTES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    KISHI, M
    DOI, K
    HORIGUCHI, Y
    ITO, K
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1989, 35 (01): : 49 - 54
  • [5] DETERMINATION OF CHLORHEXIDINE IN SALIVA USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    PESONEN, T
    HOLMALAHTI, J
    POHJOLA, J
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (01): : 222 - 225
  • [6] DIRECT DETERMINATION OF CHLORHEXIDINE IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    WAINWRIGHT, P
    COOKE, M
    ANALYST, 1986, 111 (11) : 1343 - 1344
  • [7] Determination of Carbamate Pesticides in Reservoir Water by Hollow Fiber-Based Liquid Phase Microextraction Coupled with High Performance Liquid Chromatography
    Yang Xiumin
    Wang Zhi
    Wang Chun
    Han Dandan
    Chen Yongyan
    Song Shuangju
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2007, 25 (03) : 362 - 366
  • [8] Hollow fiber supported ionic liquid membrane microextraction for determination of sulfonamides in environmental water samples by high-performance liquid chromatography
    Tao, Yong
    Liu, Jing-Fu
    Hu, Xia-Lin
    Li, Hong-Cheng
    Wang, Thanh
    Jiang, Gui-Bin
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (35) : 6259 - 6266
  • [9] Determination of seven phenoxyacid herbicides in environmental water by high performance liquid chromatography coupled with three phase hollow fiber liquid phase microextraction
    Peng Xiaojun
    Pang Jinshan
    Deng Aihua
    CHINESE JOURNAL OF CHROMATOGRAPHY, 2011, 29 (12) : 1199 - 1204
  • [10] Hollow fiber-based liquid membrane microextraction combined with high-performance liquid chromatography for extraction and determination of trimetazidine in human plasma
    Lv, Jiang
    Zhao, Xu
    Ye, Jing
    Liu, Dan
    Chen, Xiaohui
    Bi, Kaishun
    BIOMEDICAL CHROMATOGRAPHY, 2013, 27 (03) : 292 - 298