USE OF THE FLUORESCENCE-ACTIVATED CELL SORTER (FACS) FOR IN-VITRO ASSAYS OF DEVELOPMENTAL TOXICITY

被引:6
|
作者
HOOGHE, RJ
OOMS, D
机构
[1] Environment Division, Flemish Institute for Technological Research (VITO), B-2400 Mol
关键词
D O I
10.1016/0887-2333(95)00009-W
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Our objective is to predict embryotoxicity with reliable in vitro techniques. In several experimental systems, differentiation is accompanied by changes in the glycosylation pattern of cell-surface glycoconjugates. This is also the case with embryonal carcinoma cells. We have monitored the expression of receptors for wheat germ agglutinin (WGA). Murine embryonal carcinoma cells (P19 and F9) were exposed in vitro to xenobiotics for 1-3 days, then incubated successively with WGA-biotin(15 mu g/ml) and streptavidin-phycoerythrin (SA-PE) (20 mu g/ml), each for 30 min at room temperature. Cell-surface fluorescence was then analysed using a fluorescence-activated cell sorter (FACS). Exposure to 1 mu M retinoic acid, a known inducer of differentiation, altered glycosylation as indicated by changes in WGA binding. Clear-cut effects were also observed after exposure to salts of arsenic (20 mu M), or nickel (50 mu M), and to methotrexate (1 mu g/ml), fluorouracil (1.3 mu g/ml) or actinomycin D (0.04 mu g/ml). These compounds affected the percentage of positive cells the intensity of labelling, or both. Two non-teratogenic compounds (metronidazole and sulfonilamide) have also been tested and had no effect. Lectin histochemistry of embryonal carcinoma cells exposed to potentially toxic agents holds promise as a method for predicting embryotoxicity. FAGS analysis allows rapid quantification.
引用
收藏
页码:349 / 354
页数:6
相关论文
共 50 条
  • [1] FLUORESCENCE-ACTIVATED CELL SORTER (FACS) ANALYSIS OF RABBIT-CELLS
    CINADER, B
    DUBISKI, S
    CHOU, CT
    CHARPENTIER, L
    CELLULAR IMMUNOLOGY, 1988, 112 (02) : 293 - 301
  • [2] Fluorescence-activated cell sorter
    Perkel, JM
    SCIENTIST, 2004, 18 (14): : 40 - 41
  • [3] A microfabricated fluorescence-activated cell sorter
    Anne Y. Fu
    Charles Spence
    Axel Scherer
    Frances H. Arnold
    Stephen R. Quake
    Nature Biotechnology, 1999, 17 : 1109 - 1111
  • [4] A microfabricated fluorescence-activated cell sorter
    Fu, AY
    Spence, C
    Scherer, A
    Arnold, FH
    Quake, SR
    NATURE BIOTECHNOLOGY, 1999, 17 (11) : 1109 - 1111
  • [5] DETECTION AND ISOLATION OF FETAL CELLS FROM MATERNAL BLOOD USING THE FLUORESCENCE-ACTIVATED CELL SORTER (FACS)
    IVERSON, GM
    BIANCHI, DW
    CANN, HM
    HERZENBERG, LA
    PRENATAL DIAGNOSIS, 1981, 1 (01) : 61 - 73
  • [6] USE OF FLUORESCENCE ENERGY-TRANSFER TO DETECT CELL HYBRIDS WITH A FLUORESCENCE-ACTIVATED CELL SORTER
    WANDA, PE
    SMITH, JD
    FEDERATION PROCEEDINGS, 1980, 39 (06) : 2104 - 2104
  • [7] APPLICATION OF THE FLUORESCENCE-ACTIVATED CELL SORTER (FACS II) TO THE STUDY OF NORMAL HUMAN LYMPHOCYTES-B
    VALENZUELA, R
    TURINIC, R
    DEODHAR, SD
    ANTUNEZ, AR
    LABORATORY INVESTIGATION, 1980, 42 (01) : 157 - 157
  • [8] THE USE OF FLUORESCENCE-ACTIVATED CELL SORTER (FACS) TO DETERMINE T-CELL SUBSETS IN GRAVES-DISEASE PATIENTS WITH AND WITHOUT OPHTHALMOPATHY
    THOMSON, JA
    WILSON, R
    PEARSON, C
    BURNETT, AK
    MCKILLOP, JH
    JOURNAL OF ENDOCRINOLOGY, 1986, 108 : 168 - 168
  • [9] Micro-Fabricated Fluorescence-Activated Cell Sorter
    Cho, Sung Hwan
    Chen, Chun H.
    Tsai, Frank S.
    Lo, Yu-Hwa
    2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, : 1075 - +
  • [10] ISOLATION OF HUMAN MYOBLASTS WITH THE FLUORESCENCE-ACTIVATED CELL SORTER
    WEBSTER, C
    PAVLATH, GK
    PARKS, DR
    WALSH, FS
    BLAU, HM
    EXPERIMENTAL CELL RESEARCH, 1988, 174 (01) : 252 - 265