A novel method of coronary stent sizing using intravascular ultrasound: Safety and clinical outcomes

被引:1
|
作者
Wong, Christopher B. [1 ]
Hansen, Norman D. [1 ]
机构
[1] Conroe Reg Med Ctr, 213-100 Med Ctr Blvd, Conroe, TX 77304 USA
关键词
Coronary artery disease; Intravascular ultrasound; Stenting;
D O I
10.1055/s-0031-1278317
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
OBJECTIVES: The use of intravascular ultrasound (IVUS) in guiding coronary stenting has increased in recent years. The feasibility, safety and clinical outcomes of a novel method of sizing coronary stents using IVUS have not been established. The main end points of the current study are the incidence of acute and short-term complications, and the need for target vessel revascularization at six months. METHODS: Eighty-six patients underwent coronary stenting using IVUS imaging during the procedure. The optimal size of the stents was determined by using a novel method (the 'aggressive IVUS method'), ie, measuring the media-to-media dimensions of the coronary vessels at the site of the lesions using IVUS. A six-month follow-up chart review was performed following the initial stenting. RESULTS: At six months, there were two noncardiac deaths in the group. There were no acute, subacute or late stent thromboses. Target vessel revascularization and major adverse cardiac event rates remained low-at 5.8% and 9.3%, respectively. The mean (+/- SD) IVUS-derived coronary stent size (3.89 +/- 0.98 mm) using the aggressive IVUS method was significantly different from the mean IVUS-derived coronary stent size (3.46 +/- 0.96 mm) using the 'traditional IVUS method'. CONCLUSION: Aggressive sizing of the coronary stents by IVUS guidance is feasible and safe, and is associated with a favourable clinical outcome.
引用
收藏
页码:22 / 24
页数:3
相关论文
共 50 条
  • [1] ASSESSMENT OF CORONARY STENT BY INTRAVASCULAR ULTRASOUND
    DEANER, ANS
    CUBUKCU, AA
    REES, MR
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1992, 36 (01) : 124 - 126
  • [2] Resource utilization and clinical outcomes of coronary stenting: A comparison of intravascular ultrasound and angiographical guided stent implantation
    Choi, JW
    Goodreau, LM
    Davidson, CJ
    [J]. AMERICAN HEART JOURNAL, 2001, 142 (01) : 112 - 118
  • [3] Comparison of coronary vessel sizing using coronary angiography versus intravascular ultrasound in Egyptian patients
    Ebaid, Hany h
    El-sehili, Ahmed
    Rasheed, Hisham
    Ammar, Hisham
    Mahrous, Mohamed
    [J]. CARDIOMETRY, 2021, (20): : 184 - 189
  • [4] Volumetric Stent Expansion Index to Assess Tapering Lesions Using Intravascular Ultrasound and Its Clinical Outcomes
    Wu, Xi
    Wu, Ming -Xing
    Huang, Hao-Bo
    Wang, Lei
    Liu, Zhe
    Cai, Jie
    Huang, He
    [J]. REVIEWS IN CARDIOVASCULAR MEDICINE, 2024, 25 (02)
  • [5] Treatment of left main coronary artery with sirolimus eluting stent using Y-stent method: An intravascular ultrasound evaluation
    Furuse, Y
    Muramatsu, T
    Tsukahara, R
    Ito, Y
    Hirano, K
    Orita, T
    Fukunaga, S
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2005, 96 (7A): : 202H - 202H
  • [6] Clinical outcomes of coronary intravascular lithotripsy in patients with stent failure (COIL registry)
    Kuzemczak, Michal
    Lipiecki, Janusz
    Jeyalan, Visvesh
    Farhat, Hicham
    Kleczynski, Pawel
    Legutko, Jacek
    Minten, Lennert
    Bennett, Johan
    Poels, Ella
    Dens, Joseph
    Spyridopoulos, Ioakim
    Kunadian, Vijay
    Pawlowski, Tomasz
    Gil, Robert
    Egred, Mohaned
    Zaman, Azfar
    Alkhalil, Mohammad
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2023, 391
  • [7] CAN INTRAVASCULAR ULTRASOUND IMPROVE CORONARY STENT DEPLOYMENT
    GOLDBERG, SL
    COLOMBO, A
    ALMAGOR, Y
    MAIELLO, L
    GAGLIONE, A
    NAKAMURA, S
    TOBIS, JM
    [J]. CIRCULATION, 1993, 88 (04) : 597 - 597
  • [8] Intravascular ultrasound determinants of future coronary stent thrombosis
    Bhindi, Ravinay
    Testa, Luca
    van Gaal, William
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2008, 101 (05): : 743 - 744
  • [9] Quantitative Intravascular Ultrasound and Immunohistochemical Analyses of a Novel Bioabsorable Stent in a Porcine Coronary Model
    Nakamura, Takamitsu
    Shinke, Toshiro
    Geva, Sarah
    Brants, Irena
    Yin, Xinhua
    Li, Jinsheng
    Chen, Jack P.
    Chronos, Nicolas
    Goodchild, Traci
    Hou, Dongming
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 2009, 104 (6A): : 167D - 167D
  • [10] Detection of very delayed coronary stent fracture using a novel fluoroscopic stent visualization technique against intravascular ultrasound A case series
    Yang, Feifei
    Zhang, Liwei
    Huang, Dangsheng
    Shen, Dong
    Ma, Yongjiang
    Xiong, Minjun
    Zhang, Chunhong
    Tian, Miao
    [J]. MEDICINE, 2017, 96 (21)