NEUTRON TEMPERATURE-MEASUREMENTS IN A CRYOGENIC HYDROGENOUS MODERATOR

被引:0
|
作者
BALL, RM
HOOVLER, GS
LEWIS, RH
机构
[1] Babcock & Wilcox, Lynchburg, VA
关键词
D O I
10.13182/NSE95-A24121
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Benchmarkings of neutronic calculations are most successful when there is a direct correlation between a measurement and an analytic result. In the thermal neutron energy region, the fluence rate as a function of moderator temperature and position within the moderator is an area of potential correlation. The measurement can be done by activating natural lutetium. The two isotopes of the element lutetium have widely differing cross sections and permit the discrimination of flux shape and energy distributions at different reactor conditions. The Lu-175 has 1/v dependence in the thermal energy region, and Lu-176 has a resonance structure that approximates a constant cross section in the same region. The saturation activation of the two isotopes has been measured in an insulated moderator container at the center of a thermal heterogeneous reactor designed for space nuclear propulsion. The measurements were made in a hydrogenous (polyethylene) moderator at three temperatures (83, 184, and 297 K) and five locations within the moderator. Simultaneously, the reactivity effect of the change in the moderator temperature was determined to be positive with an increase in temperature. The plot of activation shows the variation in neutron fluence rate and current with temperature and explains the positive reactivity coefficient. A neutron temperature can be inferred from a postulated Maxwell-Boltzmann distribution and compared with Monte Carlo or other calculations.
引用
收藏
页码:223 / 230
页数:8
相关论文
共 50 条
  • [1] ION TEMPERATURE-MEASUREMENTS IN ALCATOR BY NEUTRON EMISSION
    PAPPAS, DS
    PARKER, RR
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1092 - 1092
  • [2] PERFORMANCE OF A CRYOGENIC NEUTRON MODERATOR FOR NEUTRON RADIOGRAPHY
    WHITTEMORE, WL
    SCHLUETER, G
    ROGERS, J
    MATERIALS EVALUATION, 1981, 39 (10) : A23 - A23
  • [3] TEMPERATURE-MEASUREMENTS
    ROBERTS, JP
    ARCHAEOMETRY, 1961, 4 (01) : 19 - 21
  • [4] Ethane as a Neutron Moderator at Cryogenic Temperatures
    El Barbari, Monia
    Ruecker, Ulrich
    Schwab, Alexander
    Chen, Junyang
    Zakalek, Paul
    Li, Jingjing
    Gutberlet, Thomas
    Brueckel, Thomas
    10TH INTERNATIONAL MEETING OF UNION FOR COMPACT ACCELERATOR-DRIVEN NEUTRON SOURCES, UCANS-10, 2024, 298
  • [5] TEMPERATURE-MEASUREMENTS IN CHILDREN
    EOFF, MJ
    JOYCE, B
    AMERICAN JOURNAL OF NURSING, 1981, 81 (05) : 1010 - 1011
  • [6] Application of a cryogenic moderator in the REMUR neutron reflectometer
    Kozhevnikov S.V.
    Zhaketov V.D.
    Petrenko A.V.
    Bulavin M.V.
    Verkhoglyadov A.Y.
    Kulikov S.A.
    Shabalin Y.P.
    Journal of Surface Investigation, 2016, 10 (01): : 1 - 9
  • [7] SPECTROSCOPIC TEMPERATURE-MEASUREMENTS
    SCHMIDT, PS
    INSTRUMENTATION TECHNOLOGY, 1975, 22 (12): : 35 - 38
  • [8] ACCURACY IN TEMPERATURE-MEASUREMENTS
    LEWIS, CW
    CHEMICAL ENGINEERING, 1993, 100 (12) : 84 - 87
  • [9] TEMPERATURE-MEASUREMENTS IN MICROTOR
    TALMADGE, S
    GANGULY, B
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1977, 22 (09): : 1202 - 1202
  • [10] TEMPERATURE-MEASUREMENTS IN EYE
    ROSENBLUTH, RF
    FATT, I