GLUCOSE-OXIDASE IMMOBILIZED POLYETHYLENE-G-ACRYLIC ACID MEMBRANE FOR GLUCOSE-OXIDASE SENSOR

被引:24
|
作者
HSIUE, GH
WANG, CC
机构
[1] Department of Chemical Engineering, National Tsing Hua University, Hsinchu
关键词
D O I
10.1002/bit.260360809
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
A polyethylene‐g‐acrylic acid (PE‐g‐AA) graft copolymer was prepared via gamma‐ray‐irradiation‐induced postirradiation procedures, and was used as support material for the immobilization of glucose oxidase. Soluble carbodiimides were used as the coupling agent. Reasonable yields were obtained with CMC but not with EDAC, EEDQ, or WRK. A number of factors were studied. (1) The use of water‐soluble carbodiimides as condensing agent was attempted and the optimum condition for coupling glucose oxidase to PE‐g‐AA was established; (2) the effect of pH and temperature on the reactivity of native and immobilized glucose oxidase was studied. When exposed to temperatures in excess of 60 °C, the immobilized glucose oxidase was less sensitive to thermal inactivation than the native enzyme. The optimum pH value for the performance of the enzyme‐immobilized membrane was 5. 6. For 200 tests, the response error of glucose sensor was less than 4% and its linear detected range was 0–1000 ppm. The obtained glucose oxidase‐immobilized PE‐g‐AA membranes were kept in pH 5. 6 acetate buffer solution at 4 °C. The glucose oxidase activity of the membrane was determined at sevenday intervals. The membranes still have 92% glucose oxidase activity even after eight weeks of storage. Copyright © 1990 John Wiley & Sons, Inc.
引用
收藏
页码:811 / 815
页数:5
相关论文
共 50 条
  • [1] STUDIES ON THE PHYSICAL-PROPERTIES OF POLYETHYLENE-G-ACRYLIC ACID TO IMMOBILIZING GLUCOSE-OXIDASE
    HSIUE, GH
    WANG, CC
    JOURNAL OF APPLIED POLYMER SCIENCE, 1990, 40 (1-2) : 235 - 247
  • [2] OXIDATION OF GLUCOSE ON IMMOBILIZED GLUCOSE-OXIDASE
    TSUKAMOTO, T
    MORITA, S
    OKADA, J
    CHEMICAL & PHARMACEUTICAL BULLETIN, 1982, 30 (03) : 782 - 788
  • [3] CHARACTERISTICS OF GLUCOSE SENSOR WITH IMMOBILIZED GLUCOSE-OXIDASE SUPPORTED BY RECONSTITUTED COLLAGEN MEMBRANE
    MORISHITA, M
    OSAKI, T
    GONDO, S
    KAGAKU KOGAKU RONBUNSHU, 1981, 7 (03) : 320 - 323
  • [4] AN INTERFERING FACTOR IN THE GLUCOSE-OXIDASE SENSING SYSTEM WITH POLYPYRROLE GLUCOSE-OXIDASE MEMBRANE
    KOJIMA, K
    NASU, H
    SHIMOMURA, M
    MIYAUCHI, S
    SYNTHETIC METALS, 1995, 71 (1-3) : 2245 - 2246
  • [5] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1982, 184 (SEP): : 47 - MICR
  • [6] IMMOBILIZED GLUCOSE-OXIDASE IN THE POTENTIOMETRIC DETECTION OF GLUCOSE
    WINGARD, LB
    CASTNER, JF
    YAO, SJ
    WOLFSON, SK
    DRASH, AL
    LIU, CC
    APPLIED BIOCHEMISTRY AND BIOTECHNOLOGY, 1984, 9 (01) : 95 - 104
  • [7] GLUCOSE-OXIDASE IMMOBILIZED WITH POLYURETHANE FOR GLUCOSE SENSING
    PHADKE, RS
    ALVA, S
    GOVIL, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1991, 202 : 147 - BIOT
  • [8] DETECTION OF GLUCOSE BY USING IMMOBILIZED GLUCOSE-OXIDASE
    MANOCHIOPINIJ, S
    SAPSAMARNWONG, C
    SIRISALI, K
    JOURNAL OF THE SCIENCE SOCIETY OF THAILAND, 1985, 11 (02): : 79 - 91
  • [9] CONVERSION OF GLUCOSE INTO GLUCONIC ACID BY MEANS OF IMMOBILIZED GLUCOSE-OXIDASE
    RICHTER, G
    HEINECKER, H
    STARKE, 1979, 31 (12): : 418 - 422
  • [10] IMPROVED ENZYME SENSOR FOR GLUCOSE WITH AN ULTRA-FILTRATION MEMBRANE AND IMMOBILIZED GLUCOSE-OXIDASE
    KOYAMA, M
    SATO, Y
    AIZAWA, M
    SUZUKI, S
    ANALYTICA CHIMICA ACTA, 1980, 116 (02) : 307 - 314