WEARABLE AIR SUPPLY FOR PNEUMATIC ARTIFICIAL HEARTS AND VENTRICULAR ASSIST DEVICES

被引:0
|
作者
SIPIN, AJ
FABREY, WJ
SMITH, SH
DOUSSOURD, JD
OLSEN, DB
机构
[1] STEVENS INST TECHNOL,NEW YORK,NY
[2] JULES L DOUSSOURD & ASSOCIATES,NEW YORK,NY
[3] UNIV UTAH,DEPT ARTIFICIAL ORGANS,SALT LAKE CITY,UT 84112
关键词
WEARABLE AIR SUPPLY; PNEUMATIC ARTIFICIAL HEART; VENTRICULAR ASSIST DEVICE;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An experimental wearable air supply for pneumatic artificial hearts and ventricular assist devices has been built and tested. The unit eliminates the need for tethering to a large, stationery driver, The miniaturized air supply is designed for ambulatory patients with implanted pulsatile pneumatic total artificial hearts (TAH) or pneumatic left-ventricular assist devices (LVAD), to permit mobility in clinical and home settings. The device has major short-term utility as a supply for pneumatic TAH or VAD bridges in patients awaiting heart transplants. The system design for the wearable driver includes a novel, fast rotary compressor, driven by a brushless direct current (DC) motor to supply air to the ventricle through an electromagnetically actuated directional valve, all controlled by a microcomputer. Stroke volume from 0 to 200 cc; pulse rate from 60 to 160 bpm, and duty cycle from 33% to 50% are selected on a keyboard, and the selected or measured parameters can be shown on a liquid crystal display. For control of delivery from a single ventricular assist device, stroke volume is controlled by variation of compressor speed. In the wearable air supply for a TAH, a single compressor drives both ventricles alternately, through a double-acting directional valve. Air volume delivered to the left ventricle is adjusted by variation of compressor speed, and air volume to the right ventricle by variation of ejection time. The effect on blood flow rate of the lower impedance to the right ventricle is compensated by provision of a two-stage compressor, in which a single stage drives the right ventricle, and both stages connected in parallel drive the left ventricle. The overall dimensions of the prototype air supply for driving either a TAH or LVAD are 4.5 by 7.8 by 4.5 inches, including an emergency battery with a duration of 15 to 30 min depending on load. The weight is presently 5.5 lb, but this will be reduced in a production design and for a dedicated LVAD air supply. The size and weight of a separately worn, rechargeable battery pack depend on the load and desired duration of operation.
引用
收藏
页码:431 / 438
页数:8
相关论文
共 50 条
  • [1] Current status of artificial hearts and ventricular assist devices
    Chu, SH
    Hsu, RB
    [J]. JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2000, 99 (02) : 79 - 85
  • [2] Japanese Guidance for Ventricular Assist Devices/Total Artificial Hearts
    Yamane, Takashi
    Kyo, Shunei
    Matsuda, Hikaru
    Abe, Yusuke
    Imachi, Kou
    Masuzawa, Toru
    Nakatani, Takeshi
    Sase, Kazuhiro
    Tabayashi, Koichi
    Takatani, Setsuo
    Tatsumi, Eisuke
    Umezu, Mitsuo
    Tsuchiya, Toshie
    [J]. ARTIFICIAL ORGANS, 2010, 34 (09) : 699 - 702
  • [3] VENTRICULAR ASSIST DEVICES AND TOTAL ARTIFICIAL HEARTS - A COMBINED REGISTRY EXPERIENCE
    PAE, WE
    [J]. ANNALS OF THORACIC SURGERY, 1993, 55 (01): : 295 - 298
  • [4] Hemocompatibility and biophysical interface of left ventricular assist devices and total artificial hearts
    Nascimbene, Angelo
    Bark, David
    Smadja, David M.
    [J]. BLOOD, 2024, 143 (08) : 661 - 672
  • [5] Hydrodynamic Impact on Blood: From Left Ventricular Assist Devices to Artificial Hearts
    Nascimbene, Angelo
    Dong, Jing-fei
    [J]. ARTERIOSCLEROSIS THROMBOSIS AND VASCULAR BIOLOGY, 2022, 42 (04) : 481 - 483
  • [6] Development of Pneumatic Lower Limb Power Assist Wear driven with Wearable Air Supply System
    Sasaki, Daisuke
    Noritsugu, Toshiro
    Takaiwa, Masahiro
    [J]. 2013 IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS (IROS), 2013, : 4440 - 4445
  • [7] Implantable Mechanical Circulatory Support: Demystifying Patients With Ventricular Assist Devices and Artificial Hearts
    Shah, Keyur B.
    Tang, Daniel G.
    Cooke, Richard H.
    Harton, Suzanne
    Flattery, Maureen
    Katlaps, Gundars J.
    Kasirajan, Vigneshwar
    Hess, Michael L.
    [J]. CLINICAL CARDIOLOGY, 2011, 34 (03) : 147 - 152
  • [8] Neurological complications associated with the use of left ventricular assist devices and total artificial hearts
    LopezYunez, AM
    Thomas, C
    Wilson, JR
    [J]. ANNALS OF NEUROLOGY, 1997, 42 (03) : T181 - T181
  • [9] Review on Electrical Motor and Pump Assemblies in Ventricular Assist Devices & Total Artificial Hearts
    Basanth, R.
    Puppala, Anil K.
    [J]. HELIX, 2018, 8 (02): : 3180 - 3187
  • [10] The Need to Change Our Objective for Artificial Heart Development: From Totally Implantable Permanent Ventricular Assist Devices to Wearable Therapeutic Ventricular Assist Devices
    Nose, Yukihiko
    Motomura, Tadashi
    Miyamoto, Hiroshi
    Ohta, Kazuhide
    Takaba, Junji
    Sugita, Yoichi
    [J]. ARTIFICIAL ORGANS, 2010, 34 (12) : 1069 - 1076