INFLUENCE OF ATTENUATION ON MEASUREMENTS OF ULTRASONIC MYOCARDIAL INTEGRATED BACKSCATTER DURING CARDIAC CYCLE (AN INVITRO STUDY)

被引:15
|
作者
VANDERSTEEN, AFW
RIJSTERBORGH, H
MASTIK, F
LANCEE, CT
VANHOORN, WM
BOM, N
机构
[1] ITERUNIV CARDIOL INST NETHERLANDS,AMSTERDAM,NETHERLANDS
[2] ERASMUS UNIV,CTR THORAX,3000 DR ROTTERDAM,NETHERLANDS
[3] DELFT UNIV TECHNOL,SEISM & ACOUST LAB,DELFT,NETHERLANDS
来源
ULTRASOUND IN MEDICINE AND BIOLOGY | 1991年 / 17卷 / 09期
关键词
ACOUSTICS; ULTRASONICS; ISCHEMIC MYOCARDIUM; MYOCARDIAL WALL THICKNESS; INTEGRATED BACKSCATTER; ATTENUATION; CARDIAC CYCLE;
D O I
10.1016/0301-5629(91)90082-8
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The purpose of this study was to investigate the dependence of ultrasonic integrated backscatter (IB) and attenuation in myocardium on wall thickness in a state of acute ischemia. Therefore, an in vitro experiment was set up in which attenuation, IB and wall thickness of a piece of freshly excised myocardium could be measured almost simultaneously. The myocardium was taken from 11 Yorkshire pigs (25-30 kg) that were killed less than 45 min before the experiment. The myocardium was placed in the far field of an ultrasound transducer (3.2-7.2 MHz) and then compressed by a stainless steel sphere. Data were processed off-line. Backscatter and attenuation were also measured as a function of frequency at 100% and 75% wall thickness, respectively. Both attenuation and IB varied during compression. Attenuation had an initial value of 2.19 +/- 0.76 dB/cm and a slope of 0.015 +/- 0.017 dB/cm% wall thickness. IB had an initial value of -76.9 +/- 2.7 dB and a slope of -0.12 +/- 0.07 dB/% wall thickness. After subtracting the influence of the attenuation from the IB the initial value of IB was -74.0 +/- 2.7 dB and the slope -0.08 +/- 0.07 dB/% wall thickness. Attenuation appeared to have a linear dependency on frequency. Backscatter appeared not to increase with increasing frequency without correction of the spectrum for the frequency dependent insonified volume.
引用
收藏
页码:869 / 877
页数:9
相关论文
共 50 条
  • [1] SYSTEMATIC VARIATIONS OF MYOCARDIAL ULTRASONIC BACKSCATTER DURING THE CARDIAC CYCLE IN DOGS
    MADARAS, EI
    BARZILAI, B
    PEREZ, JE
    SOBEL, BE
    MILLER, JG
    ULTRASONIC IMAGING, 1982, 4 (02) : 185 - 186
  • [2] MYOCARDIAL ULTRASONIC BACKSCATTER - PHYSIOLOGICAL AND PHYSICAL DETERMINANTS OF THE CARDIAC CYCLE-DEPENDENT VARIATION OF INTEGRATED BACKSCATTER
    WICKLINE, SA
    THOMAS, LJ
    MILLER, JG
    SOBEL, BE
    PEREZ, JE
    CLINICAL RESEARCH, 1985, 33 (02): : A237 - A237
  • [3] Influence of contractility on myocardial ultrasonic integrated backscatter and cyclic variation in integrated backscatter
    Bi Xiaojun
    Deng Youbin
    Pan Min
    Yang Haoyi
    Xiang Huijuan
    Chang Qing
    Li Chunlei
    Current Medical Science, 2002, 22 (3) : 233 - 234
  • [4] Influence of Contractility on Myocardial Ultrasonic Integrated Backscatter and Cyclic Variation in Integrated Backscatter
    毕小军
    邓又斌
    潘敏
    杨好意
    向慧娟
    常青
    黎春雷
    Current Medical Science, 2002, (03) : 233 - 234
  • [6] Experimental study on the detection of myocardial ultrasonic integrated backscatter
    Fan, Yu
    Li, Xiang
    Cheng, Kezheng
    Bai, Jing
    Gongye Jianzhu/Industrial Construction, 28 (08): : 337 - 341
  • [7] ANISOTROPY OF THE ULTRASONIC BACKSCATTER OF MYOCARDIAL TISSUE .1. THEORY AND MEASUREMENTS INVITRO
    MOTTLEY, JG
    MILLER, JG
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (02): : 755 - 761
  • [8] Factors affecting cardiac cycle-dependent variation of ultrasonic integrated backscatter - An in vitro study
    Nozaki, S
    Yokoi, H
    Yuba, M
    Kawanishi, K
    Matsuo, H
    CIRCULATION, 1996, 94 (08) : 4303 - 4303
  • [9] CARDIAC CYCLE VARIABILITY IN ULTRASONIC BACKSCATTER FOLLOWS CHANGES IN MYOCARDIAL-CONTRACTION DURING ISCHEMIA AND REPERFUSION
    SAGAR, KB
    RHYNE, TL
    PELKE, L
    WALSH, D
    WANN, LS
    WARLTIER, D
    CLINICAL RESEARCH, 1986, 34 (02): : A340 - A340
  • [10] REDUCED CYCLIC VARIATION OF ULTRASONIC INTEGRATED BACKSCATTER DURING MYOCARDIAL CONTRAST
    MELTZER, RS
    OHAD, DG
    REISNER, SA
    SUCHER, E
    KAPLINSKY, E
    MOTRO, M
    BATTLER, A
    VERED, Z
    CIRCULATION, 1993, 88 (04) : 163 - 163