COMPENSATING MISSING TISSUE FOR 6MV AND 10MV X-RAYS USING SOLID WATER AND LEAD

被引:0
|
作者
CONSTANTINOU, C [1 ]
HARRINGTON, J [1 ]
机构
[1] TUFTS UNIV,NEW ENGLAND MED CTR,BOSTON,MA 02111
关键词
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
引用
收藏
页码:481 / 481
页数:1
相关论文
共 50 条
  • [1] LUNG CORRECTION FACTORS FOR RADIOTHERAPY ISODOSE PLANNING USING 6MV AND 10MV X-RAYS
    CONSTANTINOU, C
    HARRINGTON, J
    [J]. MEDICAL PHYSICS, 1987, 14 (03) : 463 - 463
  • [2] COMPENSATING FILTERS FOR 10 MV X-RAYS
    BOYER, AL
    [J]. MEDICAL PHYSICS, 1980, 7 (04) : 419 - 419
  • [3] Surface Dose and Build-Up Dose Comparison of 6MV and 10MV Flattened with 6MV FFF and 10MV FFF Photon Beams with Different Detectors
    Nambiraj, Arunai
    Sigamani, Ashokkumar
    Kaviarasu, K.
    Rajesh, T.
    Karthikeyan, S.
    Subramanian, Narayanan
    Meerza, Kazem
    [J]. MEDICAL PHYSICS, 2015, 42 (06) : 3502 - 3502
  • [4] DOSIMETRY OF ANTERIOR CHEST TREATMENT BY 10 MV X-RAYS USING A TISSUE COMPENSATING FILTER
    KUBO, H
    [J]. RADIOTHERAPY AND ONCOLOGY, 1985, 4 (02) : 185 - 192
  • [5] Characterisation of 6MV and 10MV superficial build up dosimetry in tangential beam radiography
    Lacey, Craig
    Gordon, Kirsti
    Nalder, Colin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2007, 6 (04) : 229 - 241
  • [6] FOR PROSTATE IMRT USING A BEAM MODULATOR, IS THE USE OF 6MV PHOTONS SUPERIOR, INFERIOR OR EQUIVALENT TO 10MV PHOTONS?
    Derbyshire, S.
    Morgan, A.
    Thompson, R.
    Thwaites, D.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2008, 88 : S417 - S417
  • [7] eXaSkin: A novel high-density bolus for 6MV X-rays radiotherapy
    Al-Sudani, Taghreed A.
    Biasi, Giordano
    Wilkinson, Dean
    Davis, Jeremy A.
    Kearnan, Royce
    Matar, Fatima S.
    Cutajar, Dean L.
    Metcalfe, Peter
    Rosenfeld, Anatoly B.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 80 : 42 - 46
  • [8] ATTENUATION MEASUREMENTS OF 6 MV X-RAYS IN LEAD STEEL AND CONCRETE
    KARZMARK, CJ
    CAPONE, T
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1967, 12 (01): : 120 - &
  • [9] Radiochromic Film Measurements of Small Field Surface Doses from Flattened and Unflattened 6MV and 10MV Beams
    Clift, C.
    Mynampati, D.
    Yaparpalvi, R.
    Mah, D.
    [J]. MEDICAL PHYSICS, 2011, 38 (06)
  • [10] Refined gypsum effective attenuation coefficients for Co-60, 6 MV, 10 MV and 18 MV x-rays
    Glasgow, GP
    Dogan, N
    Sethi, A
    Stanton, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (01): : 63 - 71