EVALUATION OF A COMPUTERIZED POLYSOMNOGRAPHY SYSTEM

被引:10
|
作者
BIERNACKA, H [1 ]
DOUGLAS, NJ [1 ]
机构
[1] UNIV EDINBURGH,CITY HOSP,RESP MED UNIT,EDINBURGH EH10 5SB,MIDLOTHIAN,SCOTLAND
关键词
D O I
10.1136/thx.48.3.280
中图分类号
R56 [呼吸系及胸部疾病];
学科分类号
摘要
Background Manual analysis of sleep, breathing, and oxygenation records is the ''gold standard'' for diagnosing sleep abnormalities but is time consuming and cumbersome. The accuracy and cost of a computerised sleep analysis system have therefore been investigated. Methods Manual and computerised (CNS Sleep Lab) scores from 43 consecutive clinical sleep studies were prospectively compared for accuracy and the time and costs were recorded. Results There were good correlations and no systematic differences between manual and computer scoring for total sleep time, sleep onset latency, and duration of REM sleep. There was a small but clinically insignificant systematic difference in breathing pattern analysis, the number of hypopnoeas/hour being lower with manual than with computer scoring (13 (SE 3) v 15 (SE 3)/hour). There was no difference between computer and manual scoring of the frequency of apnoeas, so the frequency of apnoeas + hypopnoeas was clinically insignificantly higher with computer scoring with a highly significant correlation between the two techniques. The time taken to perform the analyses was not different between the two methods (manual 83 (SE 8) v computer 86 (SE 8) minutes). The computer system was six times more expensive than the manual system and annual running costs, including full maintenance contract and 15% depreciation, were twice as great. Conclusion The CNS Sleep Lab is sufficiently accurate for use in clinical sleep studies but is significantly more expensive and does not save technician time.
引用
收藏
页码:280 / 283
页数:4
相关论文
共 50 条
  • [1] EVALUATION OF A COMPUTERIZED POLYSOMNOGRAPHY SYSTEM
    BIERNACKI, H
    DOUGLAS, NJ
    [J]. THORAX, 1992, 47 (03) : P234 - P234
  • [2] COMPUTERIZED POLYSOMNOGRAPHY
    ANDREAS, S
    [J]. THORAX, 1994, 49 (05) : 528 - 528
  • [3] ISSUES IN COMPUTERIZED POLYSOMNOGRAPHY
    HIRSHKOWITZ, M
    MOORE, CA
    [J]. SLEEP, 1994, 17 (02) : 105 - 112
  • [4] COMPUTERIZED SEWER SYSTEM EVALUATION
    不详
    [J]. PUBLIC WORKS, 1983, 114 (09): : 89 - &
  • [5] COMPUTERIZED SENSORY EVALUATION SYSTEM
    BILLMEYER, BA
    WYMAN, G
    [J]. FOOD TECHNOLOGY, 1991, 45 (07) : 100 - 101
  • [6] Evaluation of a computerized polysomnographic system
    White, DP
    Gibb, TJ
    [J]. SLEEP, 1998, 21 (02) : 188 - 196
  • [7] Portable computerized polysomnography in attended and unattended settings
    Mykytyn, IJ
    Sajkov, D
    Neill, AM
    McEvoy, RD
    [J]. CHEST, 1999, 115 (01) : 114 - 122
  • [8] Computerized Pork Quality Evaluation System
    Liu, Li
    Ngadi, Michael O.
    [J]. MEDICAL BIOMETRICS, PROCEEDINGS, 2010, 6165 : 145 - 152
  • [9] A computerized system for evaluation of anesthesia residents
    Scharf, SM
    Foster, JP
    Barker, JR
    Ibrahim, JM
    Eichhorn, JH
    [J]. ANESTHESIA AND ANALGESIA, 1998, 86 (2S): : U121 - U121
  • [10] EVALUATION OF A COMPUTERIZED ARRHYTHMIA ALARM SYSTEM
    FROST, DA
    YANOWITZ, FG
    PRYOR, TA
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1977, 39 (04): : 583 - 587