摘要
This paper describes the performance of a high-power, high-power-density dc-to-dc converter based on the single-phase dual active bridge (DAB) topology [1]. The dual active bridge converter was shown to have very attractive features in terms of low device and component stresses, small filter components, low switching losses (by virtue of zero voltage switching), high-power density and high efficiency, bidirectional power flow, buck-boost operation, and low sensitivity to system parasitics. For high-output voltages, in the order of kilovolts, a cascaded output structure is considered. The impact of snubber capacitance and magnetizing inductance on the soft switching region of control are discussed. Various control schemes are outlined. Since the leakage inductance of the transformer is used as the main energy transfer element, coaxial transformer design techniques [2] have been utilized to carefully control this parameter. The actual layout and experimental performance of a prototype 50-kW, 50-kHz unit operating with an input voltage of 200 Vdc and an output voltage of 1600 Vdc is presented.
引用
收藏
页码:1294 / 1301
页数:8
相关论文
共 50 条
  • [1] INDUCTORLESS DC-TO-DC-CONVERTER WITH HIGH-POWER DENSITY
    CHEONG, SV
    CHUNG, H
    IOINOVICI, A
    [J]. IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1994, 41 (02) : 208 - 215
  • [2] Control for High Power Dual Active Bridge DC/DC Converter during DC fault
    Rahman, M. I.
    [J]. 2018 IEEE PES ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2018,
  • [3] Design Considerations For A High-power Dual Active Bridge DC-DC Converter With Galvanically Isolated Transformer
    Lee, Youngsil
    Watson, Alan. J.
    Vakil, Gaurang
    Wheeler, Patrick W.
    [J]. 2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 4531 - 4537
  • [4] Reactive Current Optmisation for High Power Dual Active Bridge DC/DC Converter
    Rahman, M. I.
    Jovcic, D.
    Ahmed, K. H.
    [J]. 2013 IEEE GRENOBLE POWERTECH (POWERTECH), 2013,
  • [5] A High-Power DC-DC Converter based Dual Active Bridge for MVDC Grids on Offshore Wind Farms
    Lee, Youngsil
    Vakil, Gaurang
    Feldman, Ralph
    Watson, Alan J.
    Wheeler, Patrick W.
    [J]. 2016 18TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'16 ECCE EUROPE), 2016,
  • [6] An improved Dual Active Bridge DC/DC converter
    Zhang, JM
    Xu, DM
    Qian, ZM
    [J]. PESC 2001: 32ND ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-4, CONFERENCE PROCEEDINGS, 2001, : 232 - 236
  • [7] Multivariable DC Bias Control of a High-Power ACDC Dual-Active-Bridge-Based Converter
    de Araujo, Jose W. M.
    Honorio, Dalton de A.
    Oliveira, Demercil de S., Jr.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2023, 38 (11) : 14065 - 14074
  • [8] Performance Characterization of T-Type Multilevel Dual Active Bridge DC-DC Converter
    Yadeo, Dharmendra
    Chaturvedi, Pradyumn
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2023, 59 (02) : 1877 - 1886
  • [9] DC-TO-DC-CONVERTER TRANSISTORS
    不详
    [J]. ELECTRONICS WORLD & WIRELESS WORLD, 1993, (1683): : 165 - 165
  • [10] Extending the ZVS operating range of dual active bridge high-power DC-DC converters
    Oggier, German G.
    Leidhold, Roberto
    Garcia, Guillermo O.
    Oliva, Alejandro R.
    Balda, Juan C.
    Barlow, Fred
    [J]. 2006 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-7, 2006, : 777 - 783