CHARACTERIZATION OF GYPSUM ATTENUATORS FOR RADIOTHERAPY DOSE MODIFICATION

被引:10
|
作者
ARORA, VR
WEEKS, KJ
机构
[1] Department of Radiation Oncology, Duke University Medical Center, Durham, NC 27710, United States
关键词
GYPSUM; COMPENSATORS; TRANSMISSION MEASUREMENTS; ATTENUATION COEFFICIENTS;
D O I
10.1118/1.597364
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Gypsum has significant value as a compensator material for use with high energy x rays in radiation therapy. Copensator thickness may be calculated by using an effective attenuation coefficient (mu(eff)). Detailed measurements using narrow and broad beam geometry were collected to determine this effective attenuation coefficient as a function of energy (4-15 MV), field size, depth in tissue, and thickness of the copensator. An effective attenuation coefficient relation was defined using a least8square method. It was then determined that extrapolating the broad beam data to a 0x0 cm(2) field size resulted in a good approximation to the measured narrow beam attenuation coefficient. The variations in surface dose produced by gypsum attenuators were compared to open beam results. For the energies studied, it was determined that the increase in surface dose was acceptable for clinical application.
引用
收藏
页码:77 / 81
页数:5
相关论文
共 50 条
  • [1] Individual modification of the dose, volume and fractionation of breast radiotherapy
    Bourgier, C.
    Lemanski, C.
    Draghici, R.
    Castan, F.
    Fenoglietto, P.
    Bons, F.
    Farcy-Jacquet, M. -P.
    Brengues, M.
    Gourgou, S.
    Ozsahin, M.
    Azria, D.
    CANCER RADIOTHERAPIE, 2019, 23 (6-7): : 778 - 783
  • [2] THE EFFECT OF LEAD ATTENUATORS ON DOSE IN HOMOGENEOUS PHANTOMS
    ELKHATIB, EE
    PODGORSAK, EB
    PLA, C
    MEDICAL PHYSICS, 1986, 13 (06) : 928 - 935
  • [3] Fast characterization of metal films for fiber attenuators
    Dipartimento di Elettronica, Universita' di Pavia, Via Ferrata 1, I-27100 Pavia, Italy
    Appl. Opt., 22 (5298-5301):
  • [4] Characterization of Speckles in N-Attenuators and Methods for Their
    Xiang Honggang
    Wang Rui
    Xi Jiachao
    Hou Xiaocheng
    Liu Lichun
    ACTA OPTICA SINICA, 2021, 41 (05)
  • [5] Fast characterization of metal films for fiber attenuators
    Annovazzi-Lodi, V
    Donati, S
    Merlo, S
    Beltrami, D
    APPLIED OPTICS, 1998, 37 (22): : 5298 - 5301
  • [6] Chromosomal fragility syndrome and family history of radio sensitivity as indicators for radiotherapy dose modification
    Alsbeih, G
    Story, MD
    Maor, MH
    Geara, FB
    Brock, WA
    RADIOTHERAPY AND ONCOLOGY, 2003, 66 (03) : 341 - 344
  • [7] Assessment of skin dose modification caused by application of immobilizing cast in head and neck radiotherapy
    Shokouhozaman Soleymanifard
    Mohammad Taghi Bahreyni Toossi
    Mohsen Khosroabadi
    Atefeh vejdani Noghreiyan
    Soodabeh Shahidsales
    Fatemeh Varshoee Tabrizi
    Australasian Physical & Engineering Sciences in Medicine, 2014, 37 : 535 - 540
  • [8] Assessment of skin dose modification caused by application of immobilizing cast in head and neck radiotherapy
    Soleymanifard, Shokouhozaman
    Toossi, Mohammad Taghi Bahreyni
    Khosroabadi, Mohsen
    Noghreiyan, Atefeh Vejdani
    Shahidsales, Soodabeh
    Tabrizi, Fatemeh Varshoee
    AUSTRALASIAN PHYSICAL & ENGINEERING SCIENCES IN MEDICINE, 2014, 37 (03) : 535 - 540
  • [9] GROWTH AND CHARACTERIZATION OF GYPSUM CRYSTALS
    RINAUDO, C
    ROBERT, MC
    LEFAUCHEUX, F
    JOURNAL OF CRYSTAL GROWTH, 1985, 71 (03) : 803 - 806
  • [10] Characterization of gypsum using TMDSC
    H. F. Dantas
    R. A. S. Mendes
    R. D. Pinho
    L. E. B. Soledade
    C. A. Paskocimas
    B. B. Lira
    M. O. E. Schwartz
    A. G. Souza
    Iêda M. G. Santos
    Journal of Thermal Analysis and Calorimetry, 2007, 87 : 691 - 695