THE YIELD FROM X-RAY TUBES IN TERMS OF AMBIENT DOSE-EQUIVALENT

被引:0
|
作者
ZHAO, S
KRAMER, HM
HOHLFELD, K
机构
关键词
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The yield from X my tubes in terms of the quantity ambient dose equivalent has been determined experimentally. The experimental arrangements used in all three different tubes/generators over the tube potential range from 30 to 300 kV are described and the results are presented. After having established a basis for a comparison between the old data in terms of exposure with the new data in terms of ambient dose equivalent it is demonstrated that the yield is decreased at low tube and increased at high tube voltages by a transition from old to new quantities. With the help of the data presented the strength of radiation protection shielding may be estimated using the quantity ambient dose equivalent.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 50 条
  • [1] ON THE CONVERSION COEFFICIENTS FROM FLUENCE TO AMBIENT DOSE-EQUIVALENT
    FERRARI, A
    PELLICCIONI, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 51 (04) : 251 - 255
  • [2] The Design of an Ambient Neutron Dose-Equivalent Meter
    Xia Wenming
    Jia Mingchun
    Guo Zhirong
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2011, 133 (08): : 84501 - 1
  • [3] DOSE-EQUIVALENT RATE FROM COSMIC RAY NEUTRONS
    WATT, DE
    [J]. HEALTH PHYSICS, 1967, 13 (05): : 501 - +
  • [4] AMBIENT DOSE-EQUIVALENT, DEEP DOSE-EQUIVALENT INDEX, AND ICRU SPHERE DEPTH-DOSE CALCULATIONS FOR NEUTRONS FROM 30 TO 180 MEV
    NABELSSI, BK
    HERTEL, NE
    [J]. RADIATION PROTECTION DOSIMETRY, 1994, 51 (03) : 169 - 182
  • [5] Pneumonia Detection in Chest X-Ray Dose-Equivalent CT: Impact of Dose Reduction on Detectability by Artificial Intelligence
    Schwyzer, Moritz
    Martini, Katharina
    Skawran, Stephan
    Messerli, Michael
    Frauenfelder, Thomas
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (08) : 1043 - 1047
  • [6] Diagnostic accuracy of chest X-ray dose-equivalent CT for assessing calcified atherosclerotic burden of the thoracic aorta
    Messerli, Michael
    Giannopoulos, Andreas A.
    Leschka, Sebastian
    Warschkow, Rene
    Wildermuth, Simon
    Hechelhamer, Lukas
    Bauer, Ralf W.
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2017, 90 (1080):
  • [7] Depth dose-equivalent and effective energies of photoneutrons generated by 6-18 MV X-ray beams for radiotherapy
    d'Errico, F
    Luszik-Bhadra, M
    Nath, R
    Siebert, BRL
    Wolf, U
    [J]. HEALTH PHYSICS, 2001, 80 (01): : 4 - 11
  • [8] Ambient Dose Equivalent, Effective Dose and Mean Sv/Gy Conversion Coefficients from Scattered X-Ray Spectra in Mammography
    Kunzel, R.
    Herdade, S. B.
    Costa, P. R.
    Terini, R. A.
    Levenhagen, R. S.
    [J]. WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2006, VOL 14, PTS 1-6, 2007, 14 : 2092 - +
  • [9] Fukushima radiation dose was equivalent to X-ray
    不详
    [J]. NEW SCIENTIST, 2017, 234 (3125) : 19 - 19
  • [10] ATTENUATION FACTORS FOR X-RAYS IN TERMS OF AMBIENT AND EFFECTIVE DOSE EQUIVALENT
    PEIXOTO, JE
    DREXLER, G
    ZANKL, M
    [J]. RADIATION PROTECTION DOSIMETRY, 1992, 43 (1-4) : 119 - 121