COMPARISON OF ABSORBABLE SELF-REINFORCED MULTILAYER POLY-L-LACTIDE AND METALLIC PLATES FOR THE FIXATION OF MANDIBULAR BODY OSTEOTOMIES - AN EXPERIMENTAL-STUDY IN SHEEP

被引:58
|
作者
SUURONEN, R
POHJONEN, T
TECH, L
VASENIUS, J
VAINIONPAA, S
机构
[1] TAMPERE UNIV,INST PLAST TECHNOL,BIOMAT LAB,SF-33101 TAMPERE 10,FINLAND
[2] UNIV HELSINKI,DEPT ORAL & MAXILLOFACIAL SURG,SF-00100 HELSINKI 10,FINLAND
[3] COLL VET MED HELSINKI,DEPT SURG,SF-00550 HELSINKI 55,FINLAND
关键词
D O I
10.1016/0278-2391(92)90322-Q
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Eighteen unfavorable transverse osteotomies were created in the mandibular body of sheep. Nine were fixed with self-reinforced poly-1-lactide and nine with metallic dynamic compression plates. Both plates were fixed with similar titanium screws. The follow-up times for radiographic, histologic, and microradiographic studies were 6, 12, and 24 weeks. With both methods, bony union with callus formation was accomplished by 6 weeks in all but one osteotomy in the metallic fixation group. There were no signs of plate failure. © 1992.
引用
收藏
页码:255 / 262
页数:8
相关论文
共 47 条
  • [1] COMPARISON OF ABSORBABLE SELF-REINFORCED POLY-L-LACTIDE SCREWS AND METALLIC SCREWS IN THE FIXATION OF MANDIBULAR CONDYLE OSTEOTOMIES - AN EXPERIMENTAL-STUDY IN SHEEP
    SUURONEN, R
    [J]. JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1991, 49 (09) : 989 - 995
  • [2] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide plates - An experimental study on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1997, 116 (6-7) : 352 - 356
  • [3] New generation biodegradable plate for fracture fixation: Comparison of bending strengths of mandibular osteotomies fixed with absorbable self-reinforced multi-layer poly-l-lactide plates and metallic plates - An experimental study in sheep
    Suuronen, R.
    Pohjonen, T.
    Wessman, L.
    Tormala, P.
    Vainionpaa, S.
    [J]. Clinical Materials, 1992, 9 (02): : 77 - 84
  • [4] Fixation of osteotomies of the distal femur with absorbable, self-reinforced, poly-L-lactide platesAn experimental study on rabbits
    K. Koskikare
    E. Hirvensalo
    H. Pätiälä
    P. Rokkanen
    T. Pohjonen
    P. Törmälä
    G. Lob
    [J]. Archives of Orthopaedic and Trauma Surgery, 1997, 116 : 352 - 356
  • [5] Comparison of the fixation of subcapital femoral neck osteotomies with absorbable self-reinforced poly-L-lactide lag-screws or metallic screws in sheep
    JukkalaPartio, K
    Laitinen, O
    Partio, EK
    Vasenius, J
    Vainionpaa, S
    Pohjonen, T
    Tormala, P
    Rokkanen, P
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (01) : 124 - 127
  • [6] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Koskikare, K
    Hirvensalo, E
    Patiala, H
    Rokkanen, P
    Pohjonen, T
    Tormala, P
    Lob, G
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1996, 30 (04): : 417 - 421
  • [7] Intraosseous plating with absorbable self-reinforced poly-L-lactide plates in the fixation of distal femoral osteotomies on rabbits
    Helsinki University, Central Hospital, Topeliuksenkatu 5, FIN-00260 Helsinki, Finland
    不详
    不详
    [J]. J. BIOMED. MATER. RES., 4 (417-421):
  • [8] COMPARISON OF SHEAR-STRENGTH OF OSTEOTOMIES FIXED WITH ABSORBABLE SELF-REINFORCED POLY-L-LACTIDE AND METALLIC SCREWS
    SUURONEN, R
    WESSMAN, L
    MERO, M
    TORMALA, P
    VASENIUS, J
    PARTIO, E
    VIHTONEN, K
    VAINIONPAA, S
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1992, 3 (04) : 288 - 292
  • [9] Absorbable self-reinforced poly-L-lactide plates in the fixation of osteotomies of the distal femur with special reference to the site of implantation. An experimental study.
    Koskikare, K
    [J]. ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1999, 88 (01) : 79 - 80
  • [10] SELF-REINFORCED POLY-L-LACTIDE SCREWS IN THE FIXATION OF CORTICAL BONE OSTEOTOMIES IN RABBITS
    MANNINEN, MJ
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1993, 4 (02) : 179 - 185