GASTRIC-CANCER - IMMUNOSCINTIGRAPHY WITH TC-99M LABELED ANTI-CEA BW 431/26 MONOCLONAL-ANTIBODY - CASE-REPORT

被引:0
|
作者
GONZALEZ, P
ESCOBAR, MI
CSENDES, A
LILLO, R
FODOR, M
GUZMAN, G
BAUM, RP
MASSARDO, T
GAINZA, V
OTAROLA, S
ZAVALA, A
机构
[1] GOETHE UNIV, MED CTR, DEPT MED NUCL, FRANKFURT, GERMANY
[2] INST NEUROCIRUGIA INVEST CEREBR ALFONSO ASENJO, SERV MED NUCL, SANTIAGO, CHILE
[3] UNIV CHILE, PROYECTO CONJUNTO, SANTIAGO, CHILE
[4] GOETHE UNIV, MED CTR, DEPT NUCL MED, FRANKFURT, GERMANY
关键词
STOMACH NEOPLASM; CARCINOMA; IMMUNOLOGICAL TECHNICS; RADIONUCLIDE IMAGING; TECHNETIUM; ANTIBODIES; MONOCLONAL;
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A 57 year old female had a tubular gastric adenocarcinoma confirmed by endoscopy and radiologic studies. Echotomography of the abdomen revealed multiple adenopathies. Immunoscintigraphy with 99mTc labeled anti-CEA BW 431/26 monoclonal antibody was performed. Images obtained at 6 and 24 h showed a significant uptake at the primary lesion and at periaortic adenopathies both in conventional gammacamera and single emission photon tomography. This immunoscintigraphic technique may be helpful in the management of patients with gastric cancer.
引用
收藏
页码:572 / 576
页数:5
相关论文
共 50 条
  • [1] RADIOIMMUNOSCINTIGRAPHY OF COLORECTAL-CARCINOMA WITH A TC-99(M)-LABELED ANTI-CEA MONOCLONAL-ANTIBODY (BW 431/26)
    MUXI, A
    SOLA, M
    BASSA, P
    PONS, F
    GARCIA, A
    MORAGAS, M
    LOMENA, F
    HERRANZ, R
    FERNANDEZ, R
    TRIAS, M
    SETOAIN, J
    NUCLEAR MEDICINE COMMUNICATIONS, 1992, 13 (04) : 261 - 270
  • [2] IMMUNOSCINTIGRAPHY OF CEA-PRODUCING TUMOR RECURRENCES USING A TC-99M LABELED INTACT ANTI-CEA MAB (BW 431/26)
    BAUM, RP
    HERTEL, A
    LORENZ, M
    HOR, G
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1988, 14 (7-8): : C5 - C5
  • [3] IMMUNOSCINTIGRAPHY WITH THE MONOCLONAL-ANTIBODY TC-99M BW 431/26 FOR THE DIAGNOSIS OF COLORECTAL-CARCINOMA
    MUXI, A
    BASSA, P
    MORAGAS, M
    FERNANDEZ, R
    PONS, F
    SETOAIN, J
    MEDICINA CLINICA, 1991, 96 (08): : 287 - 291
  • [4] ANTI-CEA MONOCLONAL-ANTIBODY TC-99M-BW 431/26 IN THE DIAGNOSTIC WORKUP OF PATIENTS WITH COLORECTAL-CANCER
    FRAILE, M
    BUXEDA, M
    CASTELL, J
    TORRES, M
    JIMENEZHEFFERNAN, A
    MATEO, A
    SORIANO, B
    DOMENECHTORNE, FM
    NUCLEAR MEDICINE AND BIOLOGY, 1991, 18 (01): : 53 - &
  • [6] IMMUNOSCINTIGRAPHY USING TC-99M-LABELED ANTI-CEA MONOCLONAL-ANTIBODY FOR PATIENTS WITH COLORECTAL-CANCER
    TAKENOSHITA, S
    HASHIZUME, T
    ASAO, T
    NAKAMURA, J
    KATOH, R
    ORIUCHI, N
    OOTAKE, H
    INOUE, T
    WATANABE, N
    ENDO, K
    NAGAMACHI, Y
    ANTICANCER RESEARCH, 1995, 15 (02) : 471 - 475
  • [7] TUMOR-LOCALIZATION BY IMMUNOSCINTIGRAPHY WITH ANTI-CEA ANTIBODY (TC-99M MAK BW 431026)
    KROISS, A
    TUCHMANN, A
    SCHULLER, J
    WEISS, W
    WIRTH, M
    AUINGER, C
    NEUMAYR, A
    WIENER KLINISCHE WOCHENSCHRIFT, 1989, 101 (18) : 621 - 626
  • [8] IMMUNOSCINTIGRAPHY OF COLORECTAL TUMOR-RECURRENCE, USING THE TC-99M-LABELED MONOCLONAL CEA ANTIBODY, BW-431/26
    RILINGER, N
    NIEMANN, H
    NUKLEARMEDIZIN, 1988, 27 (02) : 30 - 30
  • [9] IMMUNOSCINTIGRAPHY USING A TC-99M LABELED MONOCLONAL ANTI-CEA ANTIBODY IN THE FOLLOW-UP OF COLORECTAL-CANCER AND OTHER TUMORS PRODUCING CEA
    HERTEL, A
    BAUM, RP
    LORENZ, M
    BAEWCHRISTOW, T
    ENCKE, A
    HOR, G
    BRITISH JOURNAL OF CANCER, 1990, 62 : 34 - 36
  • [10] MONOCLONAL-ANTIBODY BW431-26 LABELED WITH TC-99M AND IN-111 - AN INVESTIGATION OF THE BIODISTRIBUTION AND THE DOSIMETRY IN PATIENTS
    BENZ, P
    OBERHAUSEN, E
    BERBERICH, R
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1991, 18 (10): : 813 - 816