A COMPARATIVE-ANALYSIS OF FLUX LIMIT MODELS FOR ULTRAFILTRATION MEMBRANES

被引:18
|
作者
PRADANOS, P
DEABAJO, J
DELACAMPA, JG
HERNANDEZ, A
机构
[1] UNIV VALLADOLID,FAC CIENCIAS,DPTO FIS APLICADA 2,E-47071 VALLADOLID,SPAIN
[2] CSIC,INST CIENCIA & TECNOL POLIMEROS,E-28006 MADRID,SPAIN
关键词
ULTRAFILTRATION MEMBRANES; FLUX LIMIT MODELS; OSMOTIC PRESSURE; GELATION; MASS TRANSFER COEFFICIENT;
D O I
10.1016/0376-7388(95)00147-5
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Here the permeate flux versus concentration characteristics of 0.1% w/w to 8% w/w aqueous solutions of dextran T-500, with a mean molecular weight of 500 000 dalton, are studied when they are tangentially filtered at 298 K through a new polyamide asymmetric membrane, with an applied pressure of 700 kPa, while the recirculation velocity in the retentate loop is kept constant in a range from 0.08 to 0.49 m/s. In such conditions, all these solutions are totally retained. The mass transfer coefficient is calculated, within the frame of the film theory for the concentration-polarization phenomenon, by studying the permeate flux as a function of concentration. It allows the evaluation of the membrane surface concentration as well. This concentration is also calculated by taking into account the osmotic limit theory. These two results for c(m) are tested by calculating the expected permeate fluxes in terms of the resistance model and comparing with the experimental ones. It can be concluded that the osmotic limit model reproduces the experimental permeate fluxes better, and in a wider range, than the gelation model.
引用
收藏
页码:129 / 142
页数:14
相关论文
共 50 条
  • [1] COMPARATIVE-ANALYSIS OF 2 VOLUMETRICAL ULTRAFILTRATION MONITORS FOR HEMODIALYSIS
    BERDEN, JHM
    WOKKE, JMP
    KOENE, RAP
    INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1986, 9 (03): : 163 - 166
  • [2] COMPARATIVE-ANALYSIS OF WAVELET MODELS AND VISION
    GAUDART, L
    CREBASSA, J
    PETRAKIAN, JP
    JOURNAL OF OPTICS-NOUVELLE REVUE D OPTIQUE, 1992, 23 (03): : 101 - 106
  • [3] A COMPARATIVE-ANALYSIS OF GLOBAL ENERGY MODELS
    ALLEN, EL
    EDMONDS, JA
    KUENNE, RE
    ENERGY ECONOMICS, 1981, 3 (01) : 2 - 13
  • [4] MODELS FOR THE COMPARATIVE-ANALYSIS OF VERTICAL MOBILITY
    BREEN, R
    QUALITY & QUANTITY, 1985, 19 (04) : 337 - 352
  • [5] Dimensional analysis of steady state flux for microfiltration and ultrafiltration membranes
    Elmaleh, S.
    Vera, L.
    Villarroel-López, R.
    Abdelmoumni, L.
    Ghaffor, N.
    Delgado, S.
    Journal of Membrane Science, 139 (01): : 37 - 45
  • [6] Dimensional analysis of steady state flux for microfiltration and ultrafiltration membranes
    Elmaleh, S
    Vera, L
    Villarroel-Lopez, R
    Abdelmoumni, L
    Ghaffour, N
    Delgado, S
    JOURNAL OF MEMBRANE SCIENCE, 1998, 139 (01) : 37 - 45
  • [7] COMPARATIVE-ANALYSIS OF PROTEIN ELECTROPHOREGRAMS OF PSEUDOMONAS OUTER MEMBRANES
    VOLCHKEVICH, ZA
    DEGTEVA, GK
    MOKICHEVA, NN
    ZHURNAL MIKROBIOLOGII EPIDEMIOLOGII I IMMUNOBIOLOGII, 1990, (10): : 32 - 35
  • [8] A COMPARATIVE-ANALYSIS OF 2 MODELS OF COLITIS IN RATS
    YAMADA, T
    MARSHALL, S
    SPECIAN, RD
    GRISHAM, MB
    GASTROENTEROLOGY, 1992, 102 (05) : 1524 - 1534
  • [9] COMPARATIVE-ANALYSIS OF DIFFERENT MODELS OF CHECKPOINTING AND RECOVERY
    NICOLA, VF
    VANSPANJE, JM
    IEEE TRANSACTIONS ON SOFTWARE ENGINEERING, 1990, 16 (08) : 807 - 821
  • [10] A COMPARATIVE-ANALYSIS OF 2 MODELS OF ENTERITIS IN RATS
    NAVEH, Y
    VLODAVSKY, E
    GASTROENTEROLOGY, 1994, 106 (04) : A258 - A258