TRANSESOPHAGEAL ELECTROCARDIOGRAPHY USING A TEMPORARY PACING BALLOON-TIPPED ELECTRODE IN ACUTE CARDIAC CARE

被引:3
|
作者
KATZ, A
GUETTA, V
OVSYSHCHER, IA
机构
[1] Division of Cardiology, Soroka Medical Center, the Faculty of Health Sciences, Beer-Sheva
关键词
ECG; esophageal;
D O I
10.1016/S0196-0644(05)82972-5
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Study objective: The study was undertaken to determine the feasibility of obtaining esophageal ECGs using resterilized 3F temporary pacing balloon-inflated electrodes in place of the more expensive pill-electrode and its associated expensive preamplifier. Setting: Tests were conducted in the emergency department and ICU. Type of participants: Subjects were 12 acutely ill patients for whom standard 12-lead surface ECGs were insufficient to afford accurate, immediate arrythmia diagnosis. Interventions: Reasonable quality esophageal ECGs were obtained by use of the electrodes, generally with minimal patient discomfort. The test never required more than ten minutes. Of the 12 patients who participated in this preliminary study, esophageal ECGs enabled definitive diagnoses to be made in ten cases. Conclusion: The use of resterilized temporary pacing balloon-inflated electrodes enables esophageal ECGs to be obtained in an acute care setting.
引用
收藏
页码:961 / 963
页数:3
相关论文
共 50 条
  • [1] TEMPORARY CARDIAC PACING USING A NEW, STEERABLE, BALLOON-TIPPED PACING CATHETER
    STEFANADIS, C
    GAVALIATSIS, I
    KALLIKAZAROS, J
    CHATZIGEORGIOU, C
    TOUTOUZAS, P
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1990, 21 (03): : 198 - 202
  • [2] THE USE OF THE BALLOON-TIPPED FLOATING CATHETER IN TEMPORARY TRANSVENOUS CARDIAC PACING
    LANG, R
    DAVID, D
    KLEIN, HO
    DISEGNI, E
    LIBHABER, C
    SARELI, P
    KAPLINSKY, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1981, 4 (05): : 491 - 496
  • [3] THE USE OF BALLOON-TIPPED FLOATING CATHETER IN ELECTIVE TEMPORARY TRANSVENOUS CARDIAC PACING
    LANG, R
    DAVID, D
    SARELI, P
    LIBHABER, C
    LEVI, A
    KLEIN, HO
    SEGNI, ED
    KAPLINSKY, E
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1980, 3 (03): : 377 - 377
  • [4] USE OF BALLOON-TIPPED ELECTRODES FOR PERMANENT CARDIAC PACING
    SLOMAN, JG
    MOND, HG
    BAILEY, B
    COLE, A
    DUFFIELD, A
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1979, 2 (06): : 579 - 585
  • [5] TRANSFEMORAL PACING WITH BALLOON-TIPPED CATHETERS
    MEISTER, SG
    BANKA, VS
    HELFANT, RH
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 225 (07): : 712 - 714
  • [6] USE OF A BALLOON-TIPPED FLOTATION ELECTRODE CATHETER FOR CARDIAC MONITORING
    CHATTERJEE, K
    SWAN, HJC
    GANZ, W
    GRAY, R
    LOEBEL, H
    FORRESTER, JS
    CHONETTE, D
    AMERICAN JOURNAL OF CARDIOLOGY, 1975, 36 (01): : 56 - 61
  • [7] A simplified approach to temporary DDD pacing using a single lead, balloon-tipped catheter with overlapping biphasic impulse stimulation
    Ferguson, JD
    Lever, N
    Channon, KM
    Bashir, Y
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2001, 24 (06): : 939 - 944
  • [8] Acute stroke: balloon-tipped catheter in thrombectomy
    Mathias, Klaus
    JOURNAL OF CARDIOVASCULAR SURGERY, 2016, 57 (01): : 48 - 51
  • [9] TRANSESOPHAGEAL ELECTROCARDIOGRAPHY AND CARDIAC PACING - DISCUSSION
    GRANT, AO
    CIRCULATION, 1987, 75 (04) : 91 - 92
  • [10] EFFECTIVENESS OF TEMPORARY PACEMAKERS WITH ACTIVE FIXATION LEAD COMPARED TO CONVENTIONAL BALLOON-TIPPED TEMPORARY PACEMAKERS
    Chedid, Maroun
    Iqbal, Omer
    Karim, Rehan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2023, 81 (08) : 96 - 96