TIME-DEPENDENT EFFICACY OF BACTERIAL FILTERS AND INFECTION RISK IN LONG-TERM EPIDURAL CATHETERIZATION

被引:43
|
作者
DECICCO, M [1 ]
MATOVIC, M [1 ]
CASTELLANI, GT [1 ]
BASAGLIA, G [1 ]
SANTINI, G [1 ]
DELPUP, C [1 ]
FANTIN, D [1 ]
TESTA, V [1 ]
机构
[1] INRCCS,CTR RIFERIMENTO ONCOL,DEPT MICROBIOL,I-33081 AVIANO,ITALY
关键词
COMPLICATIONS; CATHETER-RELATED INFECTION; EQUIPMENT; ANTIMICROBIAL FILTERS; TECHNIQUES; EPIDURAL;
D O I
10.1097/00000542-199503000-00019
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Epidural infection represents a serious albeit infrequent complication of long-term epidural catheterization. The catheter hub is regarded as the main point of entry for microorganisms among the three possible routes (hematogenous, insertion site, hub) of microbial colonization of the inserted catheter. The current study was aimed at evaluating whether frequent changing of antimicrobial filters carries an increased risk of catheter hub contamination and the time-dependent efficacy of commonly used antimicrobial filters after prolonged use. Methods: In the first part of the study, a microbiologic survey (skin, filter, hub, and catheter tip) was performed weekly in a group of 47 patients with cancer bearing subcutaneously tunneled catheters managed at home. Subsequently, the time-dependent efficacy of 96 micropore filters (32 Portex, 32 Sterifix-Braun, 32 Encapsulon TFX-medical) differing in surface areas and/or composition of the filtering membrane was evaluated in a laboratory study. Filters were perfused, under the usual conditions of clinical use (flow resistance, injection pressure, temperature), every 8 h up to 60 days, with 5 ml of two different analgesic solutions, either sterile or containing 1.5 X 10(5)/ml of Streptococcus milleri I. Eight filters of each type subsequently were flushed with a S. milleri suspension (0.5 McFarland) after 7, 14, 28, and 60 days of continuous perfusion, and the resulting filtrates were cultured. Results: In 16 of 19 positive hub cultures, the same microorganisms (species, biotype, antibiotype) were cultured from skin and filters. A statistically significant positive trend was found between the number of filter changes and the rate of positive hub cultures (chi(1)(2) trend 5.11; P = 0.02). A high correlation coefficient was found between number of positive skin cultures and number of positive filtrates (r = 0.88; P = 0.01) and between number of positive filtrates and number of positive hub cultures (r = 0.93; P = 0.003). Cultures obtained from Portex and Sterifix-Braun filters yielded no bacterial growth (64/64) throughout the study period. Cultures from Encapsulon TFX-Medical filters showed bacterial growth 2/8 at seventh day, 7/8 at the 14th day, and 16/16 from the 28th day onward. Conclusions: Our data indicate significant correlation between the incidence of catheter hub colonization and the filter-change frequency, when the skin close to the filter-hub connection is contaminated. Our results also show that Portex and Sterifix-Braun bacterial filters, when perfused with reduced volumes at low injection pressures, maintain an unmodified antimicrobial function for at leas 60 days. Based on these data, it appears clinically feasible to reduce the frequency of filter changes during long-term epidural catheterization, with a consequent possible decrease of epidural catheter colonization.
引用
收藏
页码:765 / 771
页数:7
相关论文
共 50 条
  • [1] INFECTION RISK OF LONG-TERM INDWELLING EPIDURAL CATHETERS
    CHRISTENSEN, FR
    ANDERSEN, LW
    CANADIAN ANAESTHETISTS SOCIETY JOURNAL, 1982, 29 (04) : 406 - 407
  • [2] Spinal epidural abscess after long-term epidural catheterization
    Graf, G.
    Likar, R.
    Schalk, H. -V.
    Kager, I.
    Jabarzadeh, H.
    SCHMERZ, 2007, 21 (01): : 68 - 72
  • [3] LONG-TERM CATHETERIZATION OF THE LUMBAR EPIDURAL SPACE IN RATS
    VANDENHOOGEN, RHWM
    COLPAERT, FC
    PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 1981, 15 (03) : 515 - 516
  • [4] THE LONG-TERM EFFECTS OF TIME-DEPENDENT MATERNITY BEHAVIOR
    CERONE, P
    DEMOGRAPHY, 1983, 20 (01) : 79 - 86
  • [5] Estimation of time-dependent area under the ROC curve for long-term risk prediction
    Chambless, Lloyd E.
    Diao, Guoqing
    STATISTICS IN MEDICINE, 2006, 25 (20) : 3474 - 3486
  • [6] On a generalised model for time-dependent variance with long-term memory
    Queiros, S. M. Duarte
    EPL, 2007, 80 (03)
  • [8] Time-Dependent Failure of Marble Under Long-Term Loading
    Liu, Ning
    Zhang, Chunsheng
    Chu, Weijiang
    Chen, Pingzhi
    PROCEEDINGS OF GEOSHANGHAI 2018 INTERNATIONAL CONFERENCE: ROCK MECHANICS AND ROCK ENGINEERING, 2018, : 117 - 125
  • [9] Time-dependent effects of cycloheximide on long-term memory in the cuttlefish
    Agin, V
    Chichery, R
    Maubert, E
    Chichery, MP
    PHARMACOLOGY BIOCHEMISTRY AND BEHAVIOR, 2003, 75 (01) : 141 - 146
  • [10] Long-term time-dependent stochastic modelling of extreme waves
    Erik Vanem
    Stochastic Environmental Research and Risk Assessment, 2011, 25 : 185 - 209