ENHANCEMENT AND COMPARISON OF SIMPLE TYPES OF CLOSED NETWORKS

被引:2
|
作者
Survilo, J. [1 ]
Rozenkrons, J. [1 ]
机构
[1] Riga Tech Univ, 1 Kronvalda Blvd, LV-1010 Riga, Latvia
关键词
circulating current; closed grids; network loop; non-uniform networks; quadrature booster transformer; power autotransformers; power losses; turn ratio;
D O I
10.2478/v10047-009-0016-z
中图分类号
O59 [应用物理学];
学科分类号
摘要
As distinct from radial electric power lines, in high voltage networks in most cases consumers are fed from two sides. The advantages in this arrangement are: greater reliability of electricity supply, better power quality, and smaller active power losses. However, the losses could be reduced more fully only when the network is a uniform loop or a uniform network fed at two sides by equal EMFs. If these conditions are not complied with, circulating current (or equalizing current when EMFs at two sides are not equal) arises, and the active losses increase proportionally to its square, whereas voltage losses -proportionally to its first degree. To reduce losses in such cases, these currents should be eliminated. Irrespective of their cause, a booster transformer is mostly used for this purpose. If a non-uniform loop includes voltage of one standard rating, the circulating current can be eliminated by cheaper means than with a booster transformer: by inserting an induction coil into the loop. When the loop contains two standard voltage ratings, two transformers or autotransformers are needed. In this case, to eliminate circulating current, not only an induction coil should be inserted into the loop but also the transformer turn ratio is to be appropriately adjusted. When during a day the loads change approximately proportionally, the reactance of the induction coil may remain constant; however the turn ratio of a transformer should be changed in either case -whether the loads vary proportionally or not. When the network is not a loop but has independent EMFs at two sides, two quantities must be calculated: the magnitude of EMF difference at the ends of a network, and the inductance of the coil.
引用
收藏
页码:36 / 50
页数:15
相关论文
共 50 条
  • [1] ADVERSE CURRENTS IN SIMPLE CLOSED NETWORKS
    Survilo, Josifs
    Biela, Edite
    [J]. ELECTRICAL AND CONTROL TECHNOLOGIES, 2011, : 190 - 195
  • [2] Simple bounds for closed queueing networks
    Harel, A
    Namn, S
    Sturm, J
    [J]. QUEUEING SYSTEMS, 1999, 31 (1-2) : 125 - 135
  • [3] Simple bounds for closed queueing networks
    Arie Harel
    Su Namn
    Jacob Sturm
    [J]. Queueing Systems, 1999, 31 : 125 - 135
  • [4] Constructing networks for comparison of collagen types
    Wesp, Valentin
    Scholz, Lukas
    Ziermann-Canabarro, Janine M.
    Schuster, Stefan
    Stark, Heiko
    [J]. JOURNAL OF INTEGRATIVE BIOINFORMATICS, 2024,
  • [5] Distortion in Social Networks: Comparison of Various Types of Networks
    Ben-Assuli, Ofir
    Jacobi, Arie
    [J]. 2014 INTERNATIONAL CONFERENCE ON FUTURE INTERNET OF THINGS AND CLOUD (FICLOUD), 2014, : 43 - 47
  • [6] On the decomposability of closed sets into a countable number of simple sets of various types
    Whyburn, GT
    [J]. AMERICAN JOURNAL OF MATHEMATICS, 1932, 54 : 169 - 175
  • [7] Closed types as a simple approach to safe imperative multi-stage programming
    Calcagno, C
    Moggi, E
    Taha, W
    [J]. AUTOMATA LANGUAGES AND PROGRAMMING, 2000, 1853 : 25 - 36
  • [9] TRAUMATIC DISLOCATION OF THE HIP - COMPARISON OF OPEN AND CLOSED METHODS OF TREATMENT IN CERTAIN TYPES
    EPSTEIN, HC
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1958, 40 (03): : 725 - 726
  • [10] A SIMPLE THROUGHPUT BOUND FOR LARGE CLOSED QUEUING-NETWORKS WITH FINITE CAPACITIES
    VANDIJK, NM
    [J]. PERFORMANCE EVALUATION, 1989, 10 (03) : 153 - 167