摘要
Thermospray liquid chromatography-mass spectrometry can be used for identifying and determining both paraquat (C12H14N22+) and diquat (C12H12N22+). Reversed-phase liquid chromatography was performed using a 15-cm Shim-pack CLC-ODS column, with methanol-water (80:20) + 0.1 M ammonium acetate (adjusted to pH 5 with trifluoroacetic acid) as buffers, at a flow-rate of 1.0 ml/min. The mass spectral sensitivity was best when the temperatures of the vaporizer, block and tip heater of the ion source block were set at 160, 310 and 320-degrees-C, respectively. When thermospray ionization was used, ions of m/z 186 and 183 were obtained as base peaks for paraquat and diquat, respectively. Detection limits by selected ion monitoring were of the order of 20 ng (S/N = 3.5). The mass spectra are influenced by temperature and therefore, precise temperature control is essential.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [1] DETERMINATION OF SAXITOXIN BY LIQUID-CHROMATOGRAPHY THERMOSPRAY MASS-SPECTROMETRY
    WILS, ERJ
    HULST, AG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1993, 7 (06) : 413 - 415
  • [2] DETERMINATION OF SENECIO ALKALOIDS BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    PARKER, CE
    VERMA, S
    TOMER, KB
    REED, RL
    BUHLER, DR
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1990, 19 (01): : 1 - 12
  • [3] DETERMINATION OF NONDERIVATIZED PEPTIDES BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    PILOSOF, D
    KIM, HY
    DYCKES, DF
    VESTAL, ML
    ANALYTICAL CHEMISTRY, 1984, 56 (08) : 1236 - 1240
  • [4] DETERMINATION OF ACRYLAMIDE IN SUGAR BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    CUTIE, SS
    KALLOS, GJ
    ANALYTICAL CHEMISTRY, 1986, 58 (12) : 2425 - 2428
  • [5] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF CORTICOSTEROIDS
    STEFFENRUD, S
    MAYLIN, G
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02): : 221 - 227
  • [6] APPLICATIONS OF THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BACZYNSKYJ, L
    BRONSON, GE
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12): : 253 - 254
  • [7] THERMOSPRAY INTERFACE FOR LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    BLAKLEY, CR
    VESTAL, ML
    ANALYTICAL CHEMISTRY, 1983, 55 (04) : 750 - 754
  • [8] SIMULTANEOUS DETERMINATION OF SULFONAMIDES IN MEAT BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY
    HORIE, M
    SAITO, K
    HOSHINO, Y
    NOSE, N
    TERA, M
    KITSUWA, T
    NAKAZAWA, H
    YAMANE, Y
    EISEI KAGAKU-JAPANESE JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1990, 36 (04): : 283 - 289
  • [9] DETERMINATION OF SERUM CORTISOL BY THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY - COMPARISON WITH GAS-CHROMATOGRAPHY MASS-SPECTROMETRY
    GASKELL, SJ
    ROLLINS, K
    SMITH, RW
    PARKER, CE
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1987, 14 (12): : 717 - 722
  • [10] THERMOSPRAY LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF ETHER PHOSPHOCHOLINES
    MALLET, AI
    ROLLINS, K
    BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1986, 13 (10): : 541 - 543