QUANTITATIVE IMMUNOLOGICAL DETERMINATION OF HUMAN FIBRIN-DEGRADATION AND FIBRINOGEN-DEGRADATION PRODUCTS (FDP) IN PLASMA WITH AN ANTIBODY AGAINST A SYNTHETIC PEPTIDE

被引:0
|
作者
KRAUS, M
AILLAUD, E
STUBER, W
机构
[1] Research Laboratories, Behringwerke AG, Marburg
关键词
IMMUNOASSAY; FIBRINOGEN DEGRADATION PRODUCTS; FIBRIN; FIBRINOLYSIS;
D O I
10.1016/0268-9499(94)90262-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
A new method has been developed for the quantitative determination of fibrin - and fibrinogen degradation products (FDP) in plasma. An epitope on the gamma-chain of fibrin(ogen) hidden in intact molecules is exposed in fragments E after cleavage by plasmin. A synthetic peptide of this new carboxy terminus has been used for immunization of rabbits. Antibodies isolated by immunoabsorption against a partial sequence of this peptide did not react with intact fibrinogen or fibrin, but recognized equally well all fragments E liberated from fibrinogen (AABB-E(3)), cross-linked (E(1) and E(2)) and non cross-linked fibrin (E(3)). In a sandwich-type enzyme immunoassay, the antibodies obtained were used for coating of microtitration plates, and polyclonal anti-E antibodies coupled to peroxidase for detection of bound FDP. The validity of the assay was investigated by incubation of normal and alpha(2)-antiplasmin depleted plasma with plasmin. Only in the alpha(2)-antiplasmin depleted plasma a significant and steady increase of FDP levels was detectable, reflecting in vitro generation of FDP. Since fragments E are only liberated by action of plasmin, the assay via quantification of FDP reflects free plasmin activity in vivo.
引用
收藏
页码:99 / 101
页数:3
相关论文
共 50 条
  • [1] ANTIBODIES AGAINST A NEW SYNTHETIC PEPTIDE ALLOW THE DETERMINATION OF FIBRIN-DEGRADATION AND FIBRINOGEN-DEGRADATION PRODUCTS (FDP) IN PLASMA
    KRAUS, M
    AILLAUD, E
    STUBER, W
    THROMBOSIS AND HAEMOSTASIS, 1993, 69 (06) : 1094 - 1094
  • [2] FIBRINOGEN-DEGRADATION AND FIBRIN-DEGRADATION PRODUCTS DURING FIBRINOLYTIC THERAPY
    FRANCIS, CW
    KORNBERG, A
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1992, 667 : 310 - 323
  • [3] DETERMINATION OF FIBRIN(OGEN) DEGRADATION PRODUCTS (FDP) IN PLASMA, USING A MONOCLONAL-ANTIBODY
    HAVERKATE, F
    KOOPMAN, J
    KOPPERT, P
    NIEUWENHUIZEN, W
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1985, 45 : 153 - 153
  • [4] URINARY FIBRIN/FIBRINOGEN DEGRADATION PRODUCTS (FDP) AND GLOMERULONEPHRITIS
    HEDNER, U
    EKBERG, M
    NILSSON, IM
    ACTA MEDICA SCANDINAVICA, 1974, 195 (1-2): : 81 - 85
  • [5] RADIOIMMUNOASSAYS FOR FIBRINOGEN AND FIBRIN DEGRADATION PRODUCTS IN HUMAN PLASMA
    CHEN, JP
    SCHULOF, RS
    SHURLEY, HM
    CHI, DS
    FEDERATION PROCEEDINGS, 1974, 33 (03) : 218 - 218
  • [6] RAPID TURBIDIMETRIC DETERMINATION OF FIBRINOGEN DEGRADATION PRODUCTS (FDP)
    VERBRUGGEN, HW
    WESSELS, JMC
    THROMBOSIS AND HAEMOSTASIS, 1978, 39 (01) : 12 - 21
  • [7] DETERMINATION OF FIBRINOGEN-FIBRIN DEGRADATION PRODUCTS (FDP) IN ASCITIC FLUID - VALUABLE DIAGNOSTIC TEST
    SVANBERG, L
    ASTEDT, B
    ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 1975, : 44 - 44
  • [8] FIBRINOGEN/FIBRIN DEGRADATION PRODUCTS (FDP/FDP) - CHARACTERIZATION, ANTICOAGULANT ACTIVITY, AND INFLUENCE ON LABORATORY ASSAYS
    ARNESEN, H
    MEDIKON, 1977, 6 (04): : 5 - &
  • [9] A QUANTITATIVE AUTOMATED IMMUNOASSAY FOR FIBRINOGEN FIBRIN DEGRADATION PRODUCTS
    SCHIFREEN, RS
    CEMBROWSKI, GS
    CAMPBELL, DC
    CRAIG, AR
    DEMYANOVICH, ND
    JURGAHALL, PA
    REIDER, MC
    SCHWARTZ, MW
    TUHY, PM
    WALLER, SJ
    SHATTIL, SJ
    SIGAL, HS
    BROWN, NM
    CLINICAL CHEMISTRY, 1985, 31 (09) : 1468 - 1473
  • [10] QUANTITATIVE IMMUNOCHEMICAL DETERMINATION OF DEGRADATION PRODUCTS OF FIBRINOGEN AND/OR FIBRIN WITH HIGH VOLTAGE ELECTROPHORESIS
    NILEHN, JE
    SCANDINAVIAN JOURNAL OF HAEMATOLOGY, 1971, : 215 - &