MEASUREMENT OF 3-DIMENSIONAL RADIATION-DOSE DISTRIBUTIONS USING MRI

被引:43
|
作者
PRASAD, PV [1 ]
NALCIOGLU, O [1 ]
RABBANI, B [1 ]
机构
[1] UNIV CALIF IRVINE,DEPT RADIOL SCI,DIV RADIAT ONCOL,IRVINE,CA 92717
关键词
D O I
10.2307/3578060
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Recent investigations have shown that nuclear magnetic resonance (NMR) can be used in conjunction with a suitable chemical dosimeter to estimate the dose from ionizing radiation (Gore et al., Phys Med. Biol. 29, 1189-1197, 1984). Based on this fact it was proposed that spatial dose distributions can be measured in gels infused with the chemical dosimeter using NMR imaging. There have been few such attempts and they provided only qualitative results. In this paper, we report results demonstrating the feasibility of obtaining quantitative dose distribution measurements by this technique. It is shown that quantitative dose distribution measurements necessitate the calculation of relaxation rate maps. We have determined that the spin-spin relaxation rate is a more sensitive parameter than the spin-lattice relaxation rate. It is also demonstrated that the addition of chemical sensitizers could improve the dose sensitivity of the measured NMR parameters. The two features characterizing a photon beam, depth-dose relationship, and beam profile as measured by this technique are in good agreement with the measurements using conventional methods, ionization chambers, and film dosimetry.
引用
收藏
页码:1 / 13
页数:13
相关论文
共 50 条
  • [1] RADIATION-DOSE DISTRIBUTIONS AND THEIR OPTIMIZATION
    ORR, S
    LARYNGOSCOPE, 1975, 85 (06): : 1024 - 1028
  • [2] MEASUREMENT OF RADIATION-DOSE USING DENTAL ENAMEL
    ALDRICH, JE
    PASS, B
    MEDICAL PHYSICS, 1985, 12 (04) : 520 - 520
  • [3] 3-DIMENSIONAL RADIATION-DOSE DISTRIBUTION ANALYSIS FOR BORON NEUTRON-CAPTURE THERAPY
    WHEELER, FJ
    NIGG, DW
    NUCLEAR SCIENCE AND ENGINEERING, 1992, 110 (01) : 16 - 31
  • [4] ACQUISITION AND DISPLAY OF RADIATION-DOSE DISTRIBUTIONS USING MICROCOMPUTER TECHNOLOGY
    ANTOLAK, J
    MAH, E
    BATTISTA, JJ
    SCRIMGER, JW
    MEDICAL PHYSICS, 1988, 15 (06) : 924 - 929
  • [5] BODY MASS DISTRIBUTIONS FOR RADIATION-DOSE ANALYSIS
    BILLINGS, MP
    YUCKER, WR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1974, 18 (JUN23): : 396 - 397
  • [6] MEASUREMENT OF RADIATION-DOSE DISTRIBUTIONS BY NUCLEAR MAGNETIC-RESONANCE (NMR) IMAGING
    GORE, JC
    KANG, YS
    SCHULZ, RJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (10): : 1189 - 1197
  • [7] MEASUREMENT OF RADIATION-DOSE TO THE THYROID USING POSITRON EMISSION TOMOGRAPHY
    OTT, RJ
    BATTY, V
    WEBB, S
    FLOWER, MA
    LEACH, MO
    CLACK, R
    MARSDEN, PK
    MCCREADY, VR
    BATEMAN, JE
    SHARMA, H
    SMITH, A
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (711): : 245 - 251
  • [8] A POLYMER ALANINE FILM FOR MEASUREMENTS OF RADIATION-DOSE DISTRIBUTIONS
    JANOVSKY, I
    HANSEN, JW
    CERNOCH, P
    APPLIED RADIATION AND ISOTOPES, 1988, 39 (07) : 651 - 657
  • [9] 3-DIMENSIONAL DOSE DISTRIBUTIONS FOR EXTERNAL BEAM RADIOTHERAPY
    BUKOVITZ, AG
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1978, 4 (5-6): : 493 - 498
  • [10] DIGITAL MEASUREMENT SYSTEM FOR RADIATION-DOSE DISTRIBUTION
    BLACKMORE, VJ
    NAYLOR, GP
    PHYSICS IN MEDICINE AND BIOLOGY, 1975, 20 (02): : 314 - 317