THE ANODIC-DISSOLUTION OF DENTAL AMALGAMS STUDIES WITH ABRASIVE STRIPPING VOLTAMMETRY

被引:21
|
作者
SCHOLZ, F [1 ]
RABI, F [1 ]
MULLER, WD [1 ]
机构
[1] HUMBOLDT UNIV,BEREICH MED CHARITE,DEPT STOMATOL,DIV EXPTL STOMATOL & BIOMAT SCI,O-1040 BERLIN,GERMANY
关键词
ABRASIVE STRIPPING VOLTAMMETRY; DENTAL AMALGAM; CORROSION;
D O I
10.1002/elan.1140040312
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The recently described technique abrasive stripping voltammetry was used to study the corrosion behavior of five commercial dental amalgams. Abrasive stripping voltammetry of these amalgams reveals details of the anodic dissolution of the alloys that are not accessible by other methods. Systematic studies of Sn-Hg alloys, Sn-Ag alloys, and dental amalgams lead to a method that allows the identification of the gamma-2-phase in dental amalgams. It can be shown that the non-gamma-2 amalgams have a higher stability than gamma-2-containing amalgams only in solutions of very low complexation ability. In cases of more aggressive solutions such as lemon juice, non-gamma-2 and conventional amalgams exhibit identical behavior during the anodic oxidation.