Clinical and Radiological Evaluation after Arthroscopic Rotator Cuff Repair Using Suture Bridge Technique

被引:31
|
作者
Lee, Kwang Won [1 ]
Seo, Dong Wook [2 ]
Bae, Kyoung Wan [1 ]
Choy, Won Sik [1 ]
机构
[1] Eulji Univ, Coll Med, Dept Orthoped Surg, Daejeon, South Korea
[2] Gongju Med Ctr, Dept Orthoped Surg, 130 Ungjin Ro, Gongju 314050, South Korea
关键词
Rotator cuff tear; Suture bridge technique; Retear; Magnetic resonance arthrographyrepair;
D O I
10.4055/cios.2013.5.4.306
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: We retrospectively assessed the clinical outcomes and investigated risk factors influencing retear after arthroscopic suture bridge repair technique for rotator cuff tear through clinical assessment and magnetic resonance arthrography (MRA). Methods: Between January 2008 and April 2011, sixty-two cases of full-thickness rotator cuff tear were treated with arthroscopic suture bridge repair technique and follow-up MRA were performed. The mean age was 56.1 years, and mean follow-up period was 27.4 months. Clinical and functional outcomes were assessed using range of motion, Korean shoulder score, Constant score, and UCLA score. Radiological outcome was evaluated with preoperative and follow-up MRA. Potential predictive factors that influenced cuff retear, such as age, gender, geometric patterns of tear, size of cuff tear, acromioplasty, fatty degeneration, atrophy of cuff muscle, retraction of supraspinatus, involved muscles of cuff and osteolysis around the suture anchor were evaluated. Results: Thirty cases (48.4%) revealed retear on MRA. In univariable analysis, retear was significantly more frequent in over 60 years age group (62.5%) than under 60 years age group (39.5%; p = 0.043), and also in medium to large-sized tear than small-sized tear (p = 0.003). There was significant difference in geometric pattern of tear (p = 0.015). In multivariable analysis, only age (p = 0.036) and size of tear (p = 0.030) revealed a significant difference. The mean active range of motion for forward flexion, abduction, external rotation at the side and internal rotation at the side were significantly improved at follow-up (p < 0.05). The mean Korean shoulder score, Constant score, and UCLA score increased significantly at follow-up (p < 0.01). The range of motion, Korean shoulder score, Constant score, and UCLA score did not differ significantly between the groups with retear and intact repairs (p > 0.05). The locations of retear were insertion site in 10 cases (33.3%) and musculotendinous junction in 20 cases (66.7%; p = 0.006). Conclusions: Suture bridge repair technique for rotator cuff tear showed improved clinical results. Cuff integrity after repair did not affect clinical results. Age of over 60 years and size of cuff tear larger than 1 cm were factors influencing rotator cuff retear after arthroscopic suture bridge repair technique.
引用
收藏
页码:306 / 313
页数:8
相关论文
共 50 条
  • [1] Blended Suture-bridge Technique for Arthroscopic Rotator Cuff Repair
    Chernchujit, Bancha
    Mendoza, Christian Julius P.
    Samsuya, Katreese Kimberly M.
    [J]. ARTHROSCOPY TECHNIQUES, 2023, 12 (04): : E569 - E574
  • [2] Arthroscopic Rotator Cuff Repair Using a Suture Bridge Technique Is the Repair Integrity Actually Maintained?
    Cho, Nam Su
    Lee, Bong Gun
    Rhee, Yong Girl
    [J]. AMERICAN JOURNAL OF SPORTS MEDICINE, 2011, 39 (10): : 2108 - 2116
  • [3] Arthroscopic Suture Bridge Repair Technique for Full Thickness Rotator Cuff Tear
    Yi, Jin Woong
    Cho, Nam Su
    Cho, Seung Hyun
    Rhee, Yong Girl
    [J]. CLINICS IN ORTHOPEDIC SURGERY, 2010, 2 (02) : 105 - 111
  • [4] An Augmentation Suture Technique for Arthroscopic Rotator Cuff Repair
    Omae, Hiromichi
    Yamamoto, Susumu
    Mochizuki, Yu
    Ochi, Mitsuo
    [J]. ARTHROSCOPY TECHNIQUES, 2014, 3 (03): : E313 - E315
  • [5] Arthroscopic rotator cuff repair using the suture loop shuttle technique
    Thal, Raymond
    Jennings, W. Bryan
    Heusch, Wendy L.
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2007, 23 (05): : 561.e1 - 561.e4
  • [6] Arthroscopic double-pulley suture-bridge technique for rotator cuff repair
    Kim, Kyung Cheon
    Rhee, Kwang Jin
    Shin, Hyun Dae
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (11) : 1335 - 1338
  • [7] Arthroscopic double-pulley suture-bridge technique for rotator cuff repair
    Kyung Cheon Kim
    Kwang Jin Rhee
    Hyun Dae Shin
    [J]. Archives of Orthopaedic and Trauma Surgery, 2008, 128 : 1335 - 1338
  • [8] The Combined Suture Bridge With Mason-Allen Technique Is Superior to the Conventional Suture Bridge Technique for Arthroscopic Rotator Cuff Repair
    Itoigawa, Yoshiaki
    Uehara, Hirohisa
    Tsurukami, Hironori
    Koga, Akihisa
    Morikawa, Daichi
    Maruyama, Yuichiro
    Ishijima, Muneaki
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2024, 40 (03): : 674 - 680
  • [9] Clinical and Ultrasonographic Outcomes of Arthroscopic Suture Bridge Repair for Massive Rotator Cuff Tear
    Park, Jin-Young
    Lhee, Sang-Hoon
    Oh, Kyung-Soo
    Moon, Sung Gyu
    Hwang, Jung-Taek
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2013, 29 (02): : 280 - 289
  • [10] Arthroscopic Rotator Cuff Repair With a Knotless Suture Bridge Technique: Functional and Radiological Outcomes After a Minimum Follow-Up of 5 Years
    Dukan, Ruben
    Ledinot, Pauline
    Donadio, Julia
    Boyer, Patrick
    [J]. ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2019, 35 (07): : 2003 - 2011