DETERMINATION OF PROSTATE VOLUME BY TRANSRECTAL ULTRASOUND

被引:406
|
作者
TERRIS, MK
STAMEY, TA
机构
[1] Department of Urology, Stanford Univ. Med. Center, Stanford
来源
JOURNAL OF UROLOGY | 1991年 / 145卷 / 05期
关键词
ULTRASONOGRAPHY; PROSTATE;
D O I
10.1016/S0022-5347(17)38508-7
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Estimation of prostate gland volume with transrectal ultrasound may provide important information in the evaluation of benign and malignant prostatic diseases. To determine the most accurate means of volume estimation 150 patients underwent transrectal ultrasound with 15 separate methods of volume estimation. All patients underwent subsequent radical prostatectomy or cystoprostatectomy. Prostate specimen weights were compared with the results of each volume estimation method. Step-section planimetry, previously assumed to be the most accurate means of volume measurement, exhibited a Pearson correlation coefficient of 0.93. The elliptical volume, widely used as an alternative to planimetry, demonstrated a correlation coefficient of 0.90. The most accurate method to estimate prostate weight (r = 0.94) was a variation of the prolate spheroid formula, expressed as pi/6 (transverse dimension) 2 (anteroposterior dimension). When different volume ranges were considered, this prolate spheroid formula provided the closest estimate of weight in glands of less than 40 gm. and those in the 40 to 80 gm. range. The most accurate method to estimate prostates weighing greater than 80 gm. was the formula pi/6 (transverse dimension) 3.
引用
收藏
页码:984 / 987
页数:4
相关论文
共 50 条
  • [1] DETERMINATION OF PROSTATE-GLAND VOLUME BY TRANSRECTAL ULTRASOUND - CORRELATION WITH RADICAL PROSTATECTOMY SPECIMENS
    WOLFF, JM
    BOECKMANN, W
    MATTELAER, P
    HANDT, S
    ADAM, G
    JAKSE, G
    EUROPEAN UROLOGY, 1995, 28 (01) : 10 - 12
  • [2] DETERMINATION OF PROSTATE-GLAND VOLUME BY TRANSRECTAL ULTRASOUND - CORRELATION WITH RADICAL PROSTATECTOMY SPECIMENS
    MYSCHETZKY, PS
    SUBURU, RE
    KELLY, BS
    WILSON, ML
    CHEN, SC
    LEE, F
    SCANDINAVIAN JOURNAL OF UROLOGY AND NEPHROLOGY, 1991, : 107 - 111
  • [3] Interexaminer reliability of transrectal ultrasound for estimating prostate volume
    Sech, S
    Montoya, J
    Girman, CJ
    Rhodes, T
    Roehrborn, CG
    JOURNAL OF UROLOGY, 2001, 166 (01): : 125 - 129
  • [4] Accuracy and repeatability of prostate volume measurements by transrectal ultrasound
    L M Eri
    H Thomassen
    B Brennhovd
    L L Håheim
    Prostate Cancer and Prostatic Diseases, 2002, 5 : 273 - 278
  • [5] Reassessment of nonplanimetric transrectal ultrasound prostate volume estimates
    Bazinet, M
    Karakiewicz, PI
    Aprikian, AG
    Trudel, C
    Peloquin, F
    Dessureault, J
    Goyal, M
    Begin, LR
    Elhilali, MM
    UROLOGY, 1996, 47 (06) : 857 - 862
  • [6] Accuracy and repeatability of prostate volume measurements by transrectal ultrasound
    Eri, LM
    Thomassen, H
    Brennhovd, B
    Håheim, LL
    PROSTATE CANCER AND PROSTATIC DISEASES, 2002, 5 (04) : 273 - 278
  • [7] Transperineal ultrasound for measurement of prostate volume: Validation against transrectal ultrasound
    Griffiths, Kaye A.
    Ly, Lam P.
    Jin, Bo
    Chan, Lewis
    Handelsman, David J.
    JOURNAL OF UROLOGY, 2007, 178 (04): : 1375 - 1379
  • [8] Transrectal ultrasound based prostate volume determination: Is the frustum algorithm more accurate than planimetry?
    Liu, Derek
    Usmani, Nawaid
    Sloboda, Ron S.
    MEDICAL PHYSICS, 2013, 40 (03)
  • [9] DETERMINATION OF PROSTATE VOLUME WITH TRANSRECTAL US FOR CANCER SCREENING
    DAHNERT, WF
    RADIOLOGY, 1992, 183 (03) : 625 - 627
  • [10] ESTIMATION OF PROSTATE-CANCER VOLUME BY TRANSRECTAL ULTRASOUND IMAGING
    TERRIS, MK
    MCNEAL, JE
    STAMEY, TA
    JOURNAL OF UROLOGY, 1992, 147 (03): : 855 - 857