Does MRS Lactate Peak Correlate with Lactate in the CSF and Blood?

被引:2
|
作者
Shibao, Simone [1 ]
Otaduy, Maria C. G. [1 ]
Kok, Fernando [2 ]
Leite, Claudia C. [1 ,3 ]
机构
[1] Univ Sao Paulo, Sch Med, Dept Radiol, Sao Paulo, Brazil
[2] Univ Sao Paulo, Sch Med, Dept Neurol, Sao Paulo, Brazil
[3] Univ N Carolina, Sch Med, Dept Radiol, Chapel Hill, NC 27514 USA
关键词
magnetic resonance spectroscopy; lactate peak; CSF lactate concentration; blood lactate concentration; mitochondrial disorders;
D O I
10.1055/s-0035-1564663
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Purpose Cerebrospinal fluid (CSF) or brain parenchyma lactate detection is important for the diagnosis of some diseases with aerobic cellular metabolism compromise. Our purpose is to correlate intraventricular magnetic resonance spectroscopy (MRS) lactate detection and quantification to CSF and blood lactate concentration. Methods Twenty-one patients (13 females; mean age 5 years) suspected of having mitochondrial disorders underwent proton MRS with point-resolved spectroscopy (TE = 144 ms). The volume of interest was positioned in the lateral ventricles, and LCModel was used for the MRS lactate peak detection and quantification. CSF and venous blood samples were obtained for lactate quantification immediately after MRS. Comparisons between MRS, CSF, and blood lactate detection and quantification were performed. p < 0.05 was considered significant. Results In our series, CSF lactate levels were high in 11 patients (52%) and blood serum lactate levels were high in 3 patients (14%). MRS was able to detect a lactate peak in all patients. A positive correlation between MRS lactate quantification and CSF lactate was observed (Pearson correlation coefficient = 0.750; p < 0.0001). Blood lactate did not correlate with lactate levels in the lateral ventricle measured by MRS or direct determinations of CSF lactate concentration. When noting the lactate quantification obtained by MRS, only 8 patients (as opposed to 14) presented higher values than the established normality threshold of 1.7 mmol/L. Considering CSF puncture concentration as the gold standard, we obtained 64% of sensitivity and 90% of specificity for MRS quantification. Conclusion If MRS shows increased lactate levels in the ventricles, CSF puncture is not needed for lactate increase confirmation.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
  • [1] Lactate peak on brain MRS in children with syndromic mitochondrial diseases
    Chi, Ching-Shiang
    Lee, Hsiu-Fen
    Tsai, Chi-Ren
    Chen, Wen-Shien
    Tung, Jai-Nien
    Hung, Hao-Chun
    [J]. JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2011, 74 (07) : 305 - 309
  • [2] CORRELATION BETWEEN PARIETAL WHITE MATTER, BASAL GANGLIA, AND CEREBELLAR MRI/MRS LACTATE LEVELS TO BLOOD OR CSF LACTATE LEVELS IN 742 CHILDREN
    Renaud, D. L.
    Aboian, M. A.
    Port, J. D.
    [J]. JOURNAL OF INHERITED METABOLIC DISEASE, 2010, 33 : S90 - S90
  • [3] LACTATE UPTAKE BY BRAIN AND ENTRY INTO CSF WITH SUSTAINED HIGH BLOOD LACTATE IN DOGS
    NEMOTO, EM
    HOFF, JT
    SEVERING.JW
    [J]. FEDERATION PROCEEDINGS, 1971, 30 (02) : A365 - &
  • [4] CSF lactate
    Baheerathan, Aravindhan
    Pitceathly, Robert D. S.
    Curtis, Carmel
    Davies, Nicholas W. S.
    [J]. PRACTICAL NEUROLOGY, 2020, 20 (04) : 322 - 325
  • [5] Blood lactate responses to exercise in children .1. Peak lactate concentration
    Pfitzinger, P
    Freedson, P
    [J]. PEDIATRIC EXERCISE SCIENCE, 1997, 9 (03) : 210 - 222
  • [6] EFFECT OF BLOOD IN CSF ON CSF LACTATE PYRUVATE AND BICARBONATE CONCENTRATIONS
    GRANHOLM, L
    [J]. SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1969, 23 (04): : 361 - &
  • [7] BLOOD AND CSF LACTATE LEVELS DURING HYPERBARIC HYPERVENTILATION
    POSNER, JB
    PLUM, F
    [J]. FEDERATION PROCEEDINGS, 1967, 26 (02) : 334 - &
  • [8] LACK OF RAPID EQUILIBRATION BETWEEN BLOOD AND CSF LACTATE
    POSNER, JB
    PLUM, F
    [J]. NEUROLOGY, 1966, 16 (03) : 316 - &
  • [9] Peak blood lactate and blood lactate vs workload during acclimatization to 5,050 m and in deacclimatization
    Grassi, B
    Marzorati, M
    Kayser, B
    Bordini, M
    Colombini, A
    Conti, M
    Marconi, C
    Cerretelli, P
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 80 (02) : 685 - 692
  • [10] Blood lactate: Does accusport equal accuracy?
    Hodgson, DR
    [J]. EQUINE VETERINARY JOURNAL, 1996, 28 (05) : 337 - 338