Post-tensioned structures - improved standards

被引:7
|
作者
Clark, Gordon Marshall [1 ,2 ]
机构
[1] Ramboll UK, Southampton, Hants, England
[2] Fib, Lausanne, Switzerland
关键词
cables & tendons; concrete structures; grouting;
D O I
10.1680/feng.13.00010
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Between 1979 and 1992 the UK Standing Committee on Structural Safety published annual reports which included reports on suspected deficiencies of grouting of post-tensioning tendons; then in 1992 the UK Department of Transport banned ducted grouted post-tensioning in bridges. This marked the beginning of a process of investigation and review of standards and procedures which led over 20 years to national and international bodies introducing improvements to help ensure the safety and reliability of post-tensioned structures. This is a prime example of where industry had to learn from the past, and has used that knowledge to introduce improvements, culminating in the publication of new ISO standards. This paper describes significant lessons to learn from this process for structural designers, material scientists and owners of structures, both for new designs and for asset maintenance.
引用
收藏
页码:171 / 179
页数:9
相关论文
共 50 条
  • [1] Performance and management of post-tensioned structures
    Tilly, GP
    [J]. PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2002, 152 (01) : 3 - 16
  • [2] FIRE RESISTANCE OF POST-TENSIONED STRUCTURES
    GUSTAFERRO, AH
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1973, 18 (02): : 38 - 63
  • [3] SLIPFORMED STRUCTURES CAN BE POST-TENSIONED
    不详
    [J]. CONCRETE CONSTRUCTION, 1983, 28 (03): : 281 - 281
  • [4] Corrosion in bonded post-tensioned structures
    Goodwin, F
    [J]. MATERIALS PERFORMANCE, 2002, 41 (10) : 38 - 43
  • [5] Post-tensioned timber structures: New perspectives
    D'Aveni, Antonino
    D'Agata, Giuseppe
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2017, 153 : 216 - 224
  • [6] Thin post-tensioned concrete shell structures
    Dallinger, S.
    Kollegger, J.
    [J]. TAILOR MADE CONCRETE STRUCTURES: NEW SOLUTIONS FOR OUR SOCIETY, 2008, : 158 - 158
  • [7] Concrete anchors for post-tensioned CFRP structures
    Taha, MMR
    Shrive, NG
    [J]. 2001 SECOND INTERNATIONAL CONFERENCE ON ENGINEERING MATERIALS, VOL I, 2001, : 713 - 724
  • [8] Durability of post-tensioned prestressed concrete structures
    Freyermuth, Clifford L.
    [J]. Concrete International, 1991, 13 (10) : 58 - 65
  • [9] MOMENT INFLUENCE COEFFICIENTS FOR CONTINUOUS POST-TENSIONED STRUCTURES
    TURULA, P
    FREYERMU.CL
    [J]. JOURNAL PRESTRESSED CONCRETE INSTITUTE, 1972, 17 (01): : 35 - &
  • [10] FRP tendon anchorage in post-tensioned concrete structures
    Schmidt, J. W.
    Taljsten, B.
    Bennitz, A.
    Pedersen, H.
    [J]. CONCRETE REPAIR, REHABILITATION AND RETROFITTING II, 2009, : 419 - 420