Comparability of HbA1c and lipids measured with dried blood spot versus venous samples: a systematic review and meta-analysis

被引:37
|
作者
Affan, Eshan T. [1 ,2 ]
Praveen, Devarsetty [1 ,2 ]
Chow, Clara K. [1 ,2 ,3 ]
Neal, Bruce C. [1 ,2 ]
机构
[1] George Inst Global Hlth, Missenden Rd,POB M201, Sydney, NSW 2050, Australia
[2] Univ Sydney, Sydney, NSW, Australia
[3] Westmead Hosp, Sydney, NSW, Australia
来源
BMC CLINICAL PATHOLOGY | 2014年 / 14卷
基金
英国医学研究理事会; 澳大利亚研究理事会;
关键词
Dried blood spot; HbA1c; Lipids; Meta-analysis; Total cholesterol; Triglycerides;
D O I
10.1186/1472-6890-14-21
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Levels of haemoglobin A1(c) (HbA1(c)) and blood lipids are important determinants of risk in patients with diabetes. Standard analysis methods based upon venous blood samples can be logistically challenging in resource- poor settings where much of the diabetes epidemic is occurring. Dried blood spots (DBS) provide a simple alternative method for sample collection but the comparability of data from analyses based on DBS is not well established. Methods: We conducted a systematic review and meta- analysis to define the association of findings for HbA1c and blood lipids for analyses based upon standard methods compared to DBS. The Cochrane, Embase and Medline databases were searched for relevant reports and summary regression lines were estimated. Results: 705 abstracts were found by the initial electronic search with 6 further reports identified by manual review of the full papers. 16 studies provided data for one or more outcomes of interest. There was a close agreement between the results for HbA1c assays based on venous and DBS samples (DBS = 0.9858venous + 0.3809), except for assays based upon affinity chromatography. Significant adjustment was required for assays of total cholesterol (DBS = 0.6807venous + 1.151) but results for triglycerides (DBS = 0.9557venous + 0.1427) were directly comparable. Conclusions: For HbA1c and selected blood lipids, assays based on DBS samples are clearly associated with assays based on standard venous samples. There are, however, significant uncertainties about the nature of these associations and there is a need for standardisation of the sample collection, transportation, storage and analysis methods before the technique can be considered mainstream. This should be a research priority because better elucidation of metabolic risks in resource poor settings, where venous sampling is infeasible, will be key to addressing the global epidemic of cardiovascular diseases.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] HPLC analysis of HbA1c in dried blood spot samples (DBS): a reliable future for diabetes monitoring
    Lomeo, Angelo
    Bolner, Andrea
    Scattolo, Novella
    Guzzo, Patrizia
    Amadori, Franco
    Sartoroi, Samantha
    Lomeo, Luca
    CLINICAL LABORATORY, 2008, 54 (5-6) : 161 - 167
  • [2] Estimating the effect of sulfonylurea on HbA1c in diabetes: a systematic review and meta-analysis
    J. A. Hirst
    A. J. Farmer
    A. Dyar
    T. W. C. Lung
    R. J. Stevens
    Diabetologia, 2013, 56 : 973 - 984
  • [3] Within-subject variation of HbA1c: A systematic review and meta-analysis
    Gough, Alex
    Sitch, Alice
    Ferris, Erica
    Marshall, Tom
    PLOS ONE, 2023, 18 (08):
  • [4] Motivational interventions in the management of HbA1c levels: A systematic review and meta-analysis
    Jones, Allan
    Gladstone, Beryl Primrose
    Luebeck, Marlene
    Lindekilde, Nanna
    Upton, Dominic
    Vach, Werner
    PRIMARY CARE DIABETES, 2014, 8 (02) : 91 - 100
  • [5] Estimating the effect of sulfonylurea on HbA1c in diabetes: a systematic review and meta-analysis
    Hirst, J. A.
    Farmer, A. J.
    Dyar, A.
    Lung, T. W. C.
    Stevens, R. J.
    DIABETOLOGIA, 2013, 56 (05) : 973 - 984
  • [6] Effect of stevia on blood glucose and HbA1C: A meta-analysis
    Zare, Marzieh
    Zeinalabedini, Mobina
    Ebrahimpour-Koujan, Soraiya
    Bellissimo, Nick
    Azadbakht, Leila
    DIABETES & METABOLIC SYNDROME-CLINICAL RESEARCH & REVIEWS, 2024, 18 (07)
  • [7] Preoperative HbA1c and Postoperative Outcomes in Spine Surgery A Systematic Review and Meta-Analysis
    Tao, Xu
    Matur, Abhijith V.
    Palmisciano, Paolo
    Conteh, Fatu S.
    Onyewadume, Louisa
    Duah, Henry O.
    Shukla, Geet
    Vorster, Phillip
    Gupta, Sahil
    Chilakapati, Sai S.
    Adogwa, Owoicho
    SPINE, 2023, 48 (16) : 1155 - 1165
  • [8] Comparison of HbA1c measurement in remotely prepared capillary versus standard venous blood samples
    Groenendijk, W.
    Griffin, T.
    Islam, N.
    Blake, L.
    O'Shea, P. M.
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (SUPPL 4) : 118 - 119
  • [9] Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis
    Sonia Vázquez-Morón
    Beatriz Ardizone Jiménez
    María A. Jiménez-Sousa
    José M. Bellón
    Pablo Ryan
    Salvador Resino
    Scientific Reports, 9
  • [10] Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis
    Vazquez-Moron, Sonia
    Ardizone Jimenez, Beatriz
    Jimenez-Sousa, Maria A.
    Bellon, Jose M.
    Ryan, Pablo
    Resino, Salvador
    SCIENTIFIC REPORTS, 2019, 9 (1)