FLOW-INJECTION DETERMINATION OF 3-HYDROXYBUTYRATE IN SERUM WITH AN IMMOBILIZED 3-HYDROXYBUTYRATE DEHYDROGENASE REACTOR AND FLUORESCENCE DETECTION

被引:9
|
作者
KIBA, N
KOEMADO, H
FURUSAWA, M
机构
[1] Department of Applied Chemistry and Biotechnology, Faculty of Engineering, Yamanashi University, Kofu
关键词
D O I
10.1016/0039-9140(94)E0056-W
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-injection system with an immobilized enzyme reactor is proposed for the determination of 3-hydroxybutyrate. 3-Hydroxybutyrate dehydrogenase is immobilized on aminated poly(vinyl alcohol) beads and packed into a stainless-steel column (4 cm x 4 mm I.D.). Serum is diluted and filtered. Sample solution (20 mul) is injected into the carrier stream [4mM NAD+ in glycine buffer (pH 9.3)]. The NADH formed is detected at 465 nm (excitation at 340 nm). The calibration graph is linear for 0.7-500muM 3-hydroxybutyrate; the detection limit is 0.5muM.
引用
收藏
页码:1583 / 1586
页数:4
相关论文
共 50 条
  • [1] FLOW-INJECTION DETERMINATION OF 3-HYDROXYBUTYRATE IN SERUM WITH AN IMMOBILIZED 3-HYDROXYBUTYRATE DEHYDROGENASE REACTOR AND CHEMILUMINESCENCE DETECTION
    KIBA, N
    KOEMADO, H
    FURUSAWA, M
    ANALYTICA CHIMICA ACTA, 1994, 290 (03) : 357 - 361
  • [2] Determination of 3-hydroxybutyrate in serum by flow-injection analysis using a co-immobilized 3-hydroxybutyrate dehydrogenase/NADH oxidase reactor and a chemiluminometer
    Kiba, N.
    Koemado, H.
    Inagaki, J.
    Furusawa, M.
    International Sugar Journal, 1995, 978
  • [3] DETERMINATION OF 3-HYDROXYBUTYRATE IN SERUM BY FLOW-INJECTION ANALYSIS USING A CO-IMMOBILIZED 3-HYDROXYBUTYRATE DEHYDROGENASE NADH OXIDASE REACTOR AND A CHEMILUMINOMETER
    KIBA, N
    KOEMADO, H
    INAGAKI, J
    FURUSAWA, M
    ANALYTICA CHIMICA ACTA, 1994, 298 (01) : 129 - 133
  • [4] AMPEROMETRIC PROBE FOR 3-HYDROXYBUTYRATE WITH IMMOBILIZED 3-HYDROXYBUTYRATE DEHYDROGENASE
    PALLESCHI, G
    RATHORE, HS
    MASCINI, M
    ANALYTICA CHIMICA ACTA, 1988, 209 (1-2) : 223 - 230
  • [5] Synthesis of Poly(3-hydroxybutyrate) by Immobilized Poly(3-hydroxybutyrate) Synthase
    Kenji Tajima
    Hatsumi Tannai
    Yasuharu Satoh
    Masanobu Munekata
    Polymer Journal, 2003, 35 : 407 - 410
  • [6] Synthesis of poly(3-hydroxybutyrate) by immobilized poly(3-hydroxybutyrate) synthase
    Tajima, K
    Tannai, H
    Satoh, Y
    Munekata, M
    POLYMER JOURNAL, 2003, 35 (04) : 407 - 410
  • [7] A CHEMILUMINESCENCE-FLOW INJECTION-ANALYSIS OF SERUM 3-HYDROXYBUTYRATE USING A BIOREACTOR CONSISTING OF 3-HYDROXYBUTYRATE DEHYDROGENASE AND NADH OXIDASE
    TABATA, M
    TOTANI, M
    ANALYTICAL BIOCHEMISTRY, 1995, 229 (01) : 133 - 138
  • [8] Simultaneous Determination of D-Glucose and 3-Hydroxybutyrate by Chemiluminescence Detection with Immobilized Enzymes in a Flow Injection System
    Nobutoshi Kiba
    Youhei Inoue
    Masaki Tachibana
    Kazue Tani
    Hitoshi Koizumi
    Analytical Sciences, 2003, 19 : 1203 - 1207
  • [9] Simultaneous determination of D-glucose and 3-hydroxybutyrate by chemiluminescence detection with immobilized enzymes in a flow injection system
    Kiba, N
    Inoue, Y
    Tachibana, M
    Tani, K
    Koizumi, H
    ANALYTICAL SCIENCES, 2003, 19 (08) : 1203 - 1206
  • [10] An automatic flow procedure for the determination of 3-hydroxybutyrate in animal serum and plasma
    Pires, CK
    Martelli, PB
    Reis, BF
    Lima, JLFC
    Saraiva, MLMFS
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2003, 51 (09) : 2457 - 2460