EFFICACY OF AIR CLEANING SYSTEMS IN CONTROLLING INDOOR RADON DECAY PRODUCTS

被引:28
|
作者
LI, CS [1 ]
HOPKE, PK [1 ]
机构
[1] CLARKSON UNIV, DEPT CHEM, POTSDAM, NY 13699 USA
来源
HEALTH PHYSICS | 1991年 / 61卷 / 06期
关键词
D O I
10.1097/00004032-199112000-00009
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Field evaluations of an air filtration system and an electronic air cleaner to remove Rn decay products were performed in a single-family house located in the Northford, CT area. Field measurements included the Rn concentration, particle number concentration, and concentration and activity size distribution of Rn decay products. A semi-continuous screen diffusion battery system with six parallel sampler/detector units was used to determine the concentrations and size distributions of the Rn decay products. Indoor particles were generated by common activities such as vacuuming, washing and drying clothes, opening the outside door, and cooking. Influences on the size distributions over the size range from 0.5 nm to 500 nm of Rn decay products were investigated in the domestic environment. The effect of the air cleaners was to decrease the concentration of the decay products and to reduce the equilibrium fraction. For the filtration system in particular, the activity fractions in the smallest size range were increased. However, the overall effect of the air cleaners was to reduce the median dose. The filtration unit was found to be more effective than the electronic air cleaner.
引用
收藏
页码:785 / 797
页数:13
相关论文
共 50 条
  • [1] CONTROL OF INDOOR RADON DECAY PRODUCTS BY AIR TREATMENT DEVICES
    HINDS, WC
    RUDNICK, SN
    MAHER, EF
    FIRST, MW
    [J]. JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION, 1983, 33 (02): : 134 - 136
  • [2] A COMPARISON OF RADON AND ITS DECAY PRODUCTS' BEHAVIOUR IN INDOOR AIR
    Trevisi, R.
    Cardellini, F.
    Leonardi, F.
    Trassierra, C. Vargas
    Franci, D.
    [J]. RADIATION PROTECTION DOSIMETRY, 2014, 162 (1-2) : 171 - 175
  • [3] RADON AND ITS DECAY PRODUCTS IN INDOOR AIR - NAZAROFF,WW, NERO,AV
    EATON, RS
    [J]. SCIENCE, 1988, 241 (4868) : 990 - 990
  • [4] Levels of Nanosize Radon Decay Products in Indoor Air: A Comparison for Different Environments
    Vaupotic, Janja
    [J]. COLLEGIUM ANTROPOLOGICUM, 2008, 32 : 99 - 104
  • [5] RADON AND ITS DECAY PRODUCTS IN INDOOR AIR - NAZAROFF,WW, NERO,AV
    FREMLIN, J
    [J]. NATURE, 1988, 335 (6186) : 125 - 126
  • [6] Nanoaerosols Including Radon Decay Products in Outdoor and Indoor Air at a Suburban Site
    Smerajec, Mateja
    Vaupotic, Janja
    [J]. JOURNAL OF TOXICOLOGY, 2012, 2012
  • [7] Radon and its decay products in an air-conditioned auditorium in correlation with indoor air parameters
    Polednik, Bernard
    Kozak, Krzysztof
    Mazur, Jadwiga
    Dudzinska, Marzenna
    Grzadziel, Dominik
    [J]. INDOOR AND BUILT ENVIRONMENT, 2017, 26 (05) : 621 - 630
  • [8] Radon decay products in outdoor air
    Porstendörfer, J
    Gründel, M
    [J]. NATURAL RADIATION ENVIRONMENT VII, 2005, 7 : 56 - 65
  • [9] Reduction of indoor radon by air cleaning - Case study
    Lowe, SA
    Pettenato, R
    [J]. JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2000, 126 (12): : 1125 - 1130
  • [10] UNATTACHED RADON DECAY PRODUCTS IN MINE AIR
    MERCER, TT
    [J]. HEALTH PHYSICS, 1975, 28 (02): : 158 - 162