POLY-L-LYSINE CAUSES FALSE POSITIVE RESULTS IN ELISA METHODS DETECTING ANTI-DSDNA ANTIBODIES

被引:10
|
作者
KROUBOUZOS, G
TOSCA, A
KONSTADOULAKIS, MM
VARELZIDIS, A
机构
[1] UNIV ATHENS,A SYGROS HOSP,IMMUNODERMATOL LAB,ATHENS,GREECE
[2] UNIV CRETE,DEPT DERMATOL,IRAKLION,GREECE
[3] UNIV ATHENS,IPPOKRATION HOSP,DEPT SURG,ATHENS,GREECE
关键词
D O I
10.1016/0022-1759(92)90180-2
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
引用
收藏
页码:261 / 263
页数:3
相关论文
共 10 条
  • [1] The Use of Poly-L-Lysine as a Capture Agent to Enhance the Detection of Antinuclear Antibodies by ELISA
    Stearns, Nancy A.
    Zhou, Shuxia
    Petri, Michelle
    Binder, Steven R.
    Pisetsky, David S.
    PLOS ONE, 2016, 11 (09):
  • [2] Comparison of two Farr RIA methods and an ELISA assay for the detection of High Avidity anti-dsDNA antibodies
    Taylor, DJ
    Budd, R
    Harley, E
    Isenberg, D
    Bradwell, AR
    CLINICAL CHEMISTRY, 2005, 51 : A75 - A75
  • [3] Evaluation of a standardised Vi poly-L-lysine ELISA for serology of Vi capsular polysaccharide antibodies
    Rigsby, Peter
    Beamish, Emma
    Hockley, Jason
    Atkinson, Eleanor
    Hitri, Krisztina
    Jones, Elizabeth
    Yang, Jae Seung
    Qadri, Firdausi
    Bachtiar, Novilia S.
    Elias, Sean C.
    Goel, Akshay
    Mishra, Ravipratapnarayan
    Dugyala, Raju
    Pasetti, Marcela F.
    Meiring, James E.
    Mbewe, Maurice
    Gordon, Melita A.
    Pollard, Andrew J.
    Logan, Alastair
    Rijpkema, Sjoerd
    BIOLOGICALS, 2020, 66 : 21 - 29
  • [4] PRODUCTION OF ANTI-GLUCAGON ANTIBODIES IN POLY-L-LYSINE RESPONDER GUINEA-PIGS
    CUATRECASAS, P
    ILLIANO, G
    GREEN, I
    NATURE-NEW BIOLOGY, 1971, 230 (10): : 60 - +
  • [5] IMMUNOFLUORESCENCE WITH MONOCLONAL-ANTIBODIES ON POLY-L-LYSINE COATED SLIDES - AN ALTERNATIVE TO CONVENTIONAL METHODS
    MEHTA, MM
    MUNKER, R
    KRANZ, B
    THIEL, E
    THIERFELDER, S
    BLUT, 1983, 47 (04): : 237 - 242
  • [6] PARTICLE-LABELED ANTIBODIES .1. ANTI T-CELL ANTIBODIES ATTACHED TO PLASTIC BEADS BY POLY-L-LYSINE
    GABRILOVAC, J
    PACHMANN, K
    RODT, H
    JAGER, G
    THIERFELDER, S
    JOURNAL OF IMMUNOLOGICAL METHODS, 1979, 30 (02) : 161 - 170
  • [7] A TRINITROPHENYL(TNP) POLY-L-LYSINE HORSERADISH-PEROXIDASE CONJUGATE FOR THE DETECTION OF ANTI-TNP ANTIBODIES INVIVO
    CLAASSEN, E
    VANROOIJEN, N
    JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1985, 33 (08) : 840 - 844
  • [8] False-positive results in ELISA-based anti FVIII antibody assay may occur with lupus anticoagulant and phospholipid antibodies
    Sahud, M.
    Zhukov, O.
    Mo, K.
    Popov, J.
    Dlott, J.
    HAEMOPHILIA, 2012, 18 (05) : 777 - 781
  • [9] Reduction of anti-Galα1,3Gal antibodies by infusion of types 2 and 6 gal trisaccharides conjugated to poly-L-lysine
    Kuwaki, K
    Knosalla, C
    Moran, K
    Alt, A
    Katopodis, AG
    Duthaler, RO
    Schuurman, HJ
    Awwad, M
    Cooper, DKC
    XENOTRANSPLANTATION, 2004, 11 (02) : 210 - 215
  • [10] False positive results in GTI-Pak plus ELISA kits due to the presence of anti-mouse antibodies in patient samples.
    Leach, MF
    Au-Buchon, JP
    TRANSFUSION, 2002, 42 (09) : 64S - 64S