COMPARISON OF THE USE OF THE LARYNGEAL MASK AND FACE MASK BY INEXPERIENCED PERSONNEL

被引:26
|
作者
TOLLEY, PM [1 ]
WATTS, ADJ [1 ]
HICKMAN, JA [1 ]
机构
[1] FREMANTLE HOSP,DEPT ANAESTHESIA,FREMANTLE,WA 6160,AUSTRALIA
关键词
EQUIPMENT; FACE MASK; LARYNGEAL MASK AIRWAY; VENTILATION; MANUAL;
D O I
10.1093/bja/69.3.320
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Ten junior doctors with no postgraduate anaesthetic experience attempted to ventilate the lungs of 50 anaesthetized patients, using either a laryngeal mask or a Guedel airway and face mask. Success was defined as the production of two successive tidal volumes exceeding 800 ml within 40 s. The failure rate was significantly greater using the laryngeal mask compared with the face mask (P < 0.05) and the average time was significantly longer with the laryngeal mask than with the face mask (P < 0.01). The results from this investigation suggest the laryngeal mask airway cannot be recommended as a resuscitation device for use by inexperienced operators.
引用
收藏
页码:320 / 321
页数:2
相关论文
共 50 条
  • [1] USE OF THE LARYNGEAL MASK AND FACE MASK BY INEXPERIENCED PERSONNEL
    TIGHE, SQM
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (01) : 114 - 115
  • [2] A comparison of the intubating and standard laryngeal mask airways for airway management by inexperienced personnel
    Choyce, A
    Avidan, MS
    Shariff, A
    Del Aguila, M
    Radcliffe, JJ
    Chan, T
    [J]. ANAESTHESIA, 2001, 56 (04) : 357 - 360
  • [3] Tracheal intubation via the intubating laryngeal mask by inexperienced personnel
    Dimitriou, V
    Voyagis, GS
    [J]. BRITISH JOURNAL OF ANAESTHESIA, 2000, 84 (04) : 538 - 538
  • [4] Laryngeal mask vs intubating laryngeal mask: Insertion and ventilation by inexperienced resuscitators
    Burgoyne, L
    Cyna, A
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2001, 29 (06) : 604 - 608
  • [5] Ease of insertion of the laryngeal mask airway by inexperienced personnel when using an introducer
    Dingley, J
    Baynham, P
    Swart, M
    Vaughan, RS
    [J]. ANAESTHESIA, 1997, 52 (08) : 756 - 760
  • [6] Laryngeal mask LMA Supreme™. Application by medical personnel inexperienced in airway management
    Timmermann, A.
    Cremer, S.
    Heuer, J.
    Braun, U.
    Graf, B. M.
    Russo, S. G.
    [J]. ANAESTHESIST, 2008, 57 (10): : 970 - 975
  • [7] COMPARISON OF OUTCOME WITH THE USE OF LARYNGEAL MASK, FACE MASK ORAL AIRWAY AND ENDOTRACHEAL-TUBE IN CHILDREN
    WATCHA, MF
    TAN, TSH
    SAFAVI, F
    PAYNE, CT
    TEUFEL, AE
    [J]. ANESTHESIA AND ANALGESIA, 1994, 78 (02): : U249 - U249
  • [8] USE OF THE LARYNGEAL MASK AIRWAY AS AN ALTERNATIVE TO A FACE MASK DURING OUTPATIENT ARTHROSCOPY
    SMITH, I
    WHITE, PF
    [J]. ANESTHESIOLOGY, 1992, 77 (05) : 850 - 855
  • [9] A comparison of the PAxpress™ and face mask plus Guedel airway by inexperienced personnel after mannequin-only training
    Dimitriou, V
    Voyagis, GS
    Iatrou, C
    Brimacombe, J
    [J]. ANESTHESIA AND ANALGESIA, 2003, 96 (04): : 1214 - 1217
  • [10] A comparison of the ProSeal and classic laryngeal mask airways for airway management by inexperienced personnel after manikin-only training
    Coulson, A
    Brimacombe, J
    Keller, C
    Wiseman, L
    Ingham, T
    Cheung, D
    Popwycz, L
    Hall, B
    [J]. ANAESTHESIA AND INTENSIVE CARE, 2003, 31 (03) : 286 - 289