CATALYSIS OF ION TRANSFER BY TETRAPHENYLBORATES IN NEUTRAL CARRIER-BASED ION-SELECTIVE ELECTRODES

被引:185
|
作者
GEHRIG, P [1 ]
MORF, WE [1 ]
WELTI, M [1 ]
PRETSCH, E [1 ]
SIMON, W [1 ]
机构
[1] SWISS FED INST TECHNOL,DEPT ORGAN CHEM,UNIV STR 16,CH-8092 ZURICH,SWITZERLAND
关键词
D O I
10.1002/hlca.19900730124
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
For certain ionophores of extremely high lipophilicity, kinetic limitations of the carrier‐induced ion transfer between aqueous and membrane phase may heavily disturb the electromotive behaviour of the ion‐selective membrane electrode. These limitations may be overcome by adding tetraphenylborates to the membrane phase. Membranes prepared with different 3,6‐dioxaoctanediamide homologues and potassium tetrakis(P‐chlorophenyl)borate as phase‐transfer catalyst all exhibit the same ion selectivity as well as theoretical electrode response. This behaviour is corroborated by a theoretical description of the ion‐transfer process. Copyright © 1990 Verlag GmbH & Co. KGaA, Weinheim
引用
收藏
页码:203 / 212
页数:10
相关论文
共 50 条
  • [1] NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODES
    AMMANN, D
    MORF, WE
    ANKER, P
    MEIER, PC
    PRETSCH, E
    SIMON, W
    ION-SELECTIVE ELECTRODE REVIEWS, 1983, 5 (01): : 3 - 92
  • [2] DESIGN AND APPLICATION OF NEUTRAL CARRIER-BASED ION-SELECTIVE ELECTRODES - PLENARY LECTURE
    SIMON, W
    PRETSCH, E
    MORF, WE
    AMMANN, D
    OESCH, U
    DINTEN, O
    ANALYST, 1984, 109 : 207 - 209
  • [3] NEUTRAL-CARRIER-BASED ION-SELECTIVE ELECTRODES
    OGGENFUSS, P
    MORF, WE
    OESCH, U
    AMMANN, D
    PRETSCH, E
    SIMON, W
    ANALYTICA CHIMICA ACTA, 1986, 180 : 299 - 311
  • [4] Selectivity of carrier-based ion-selective electrodes: Is the problem solved?
    Bakker, E
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1997, 16 (05) : 252 - 260
  • [5] Subcellular carrier-based optical ion-selective nanosensors
    Carregal-Romero, Susana
    Montenegro, Jose-Maria
    Parak, Wolfgang J.
    Riveragil, Pilar
    FRONTIERS IN PHARMACOLOGY, 2012, 3
  • [6] Effect of lipophilic ion-exchanger leaching on the detection limit of carrier-based ion-selective electrodes
    Telting-Diaz, M
    Bakker, E
    ANALYTICAL CHEMISTRY, 2001, 73 (22) : 5582 - 5589
  • [7] Selectivity comparison of neutral carrier-based ion-selective optical and potentiometric sensing schemes
    Bakker, E
    ANALYTICA CHIMICA ACTA, 1997, 350 (03) : 329 - 340
  • [8] ROLE OF MEMBRANE MEDIA IN POTENTIOMETRIC SELECTIVITY OF ANION CARRIER-BASED ION-SELECTIVE ELECTRODES
    JYO, A
    MINAKAMI, R
    KANDA, Y
    EGAWA, H
    SENSORS AND ACTUATORS B-CHEMICAL, 1993, 13 (1-3) : 200 - 204
  • [9] NEUTRAL CARRIER-BASED ION-SELECTIVE ELECTRODE WITH SIMILAR SENSITIVITY TO DIFFERENT MONOVALENT CATIONS AS A DETECTOR IN ION CHROMATOGRAPHY
    KWON, KH
    PAENG, KJ
    LEE, DK
    LEE, IC
    HONG, US
    CHA, GS
    JOURNAL OF CHROMATOGRAPHY A, 1994, 688 (1-2) : 350 - 356
  • [10] Ion-pairing ability, chemical stability, and selectivity behavior of halogenated dodecacarborane cation exchangers in neutral carrier-based ion-selective electrodes
    Peper, S
    Qin, Y
    Almond, P
    McKee, M
    Telting-Diaz, M
    Albrecht-Schmitt, T
    Bakker, E
    ANALYTICAL CHEMISTRY, 2003, 75 (09) : 2131 - 2139