AMPEROMETRIC BIOSENSING OF ORGANIC PEROXIDES WITH PEROXIDASE-MODIFIED ELECTRODES

被引:76
|
作者
WANG, J
FREIHA, B
NASER, N
ROMERO, EG
WOLLENBERGER, U
OZSOZ, M
EVANS, O
机构
[1] US EPA,ENVIRONM MONITORING SYST LAB,CINCINNATI,OH 45268
[2] UNIV AUTONOMA MADRID,MADRID 34,SPAIN
[3] CENT INST MOLEC BIOL,BERLIN,GERMANY
关键词
AMPEROMETRY; BIOSENSORS; ELECTRODES; PEROXIDASE-MODIFIED ELECTRODES;
D O I
10.1016/0003-2670(91)90012-T
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An amperometric enzyme electrode for organic peroxides, based on the incorporation of horseradish peroxidase (HRP) into a carbon paste matrix, is reported. The electrode responds rapidly to low (micromolar) concentrations of such peroxides, in accordance to the following sensitivity trend: butanone peroxide > tert-butyl peroxibenzoate > cumene hydroperoxides > triphenylmethyl hydroperoxide > tert-butyl hydroperoxide > tert-amyl perbenzoate > tert-butyl peroxiacetate. The effect of various operational parameters is explored for optimum analytical performance. The dynamic properties of this electrode are exploited for detection in flow injection systems. Work in mixed nonaqueous-aqueous media allows the quantitation of highly hydrophobic peroxides and extension of the linear range. Similar organic peroxide detection is reported for the incorporation of HRP within a rigid graphite-epoxy matrix, and for a tissue (horseradish-root) modified electrode. Applicability of the HRP electrode for assays of drinking water is illustrated and prospects for its utility in environmental work are discussed. Analogous measurements using another (fungal) peroxidase are reported.
引用
收藏
页码:81 / 88
页数:8
相关论文
共 50 条
  • [1] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A.
    Emneus, J.
    Ruzgas, T.
    Gorton, L.
    Analytica Chimica Acta, 347 (1-2):
  • [2] Amperometric detection of phenols using peroxidase-modified graphite electrodes
    Lindgren, A
    Emneus, J
    Ruzgas, T
    Gorton, L
    MarkoVarga, G
    ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) : 51 - 62
  • [3] REACTIVITIES OF AMPEROMETRIC ORGANIC-PHASE PEROXIDASE-MODIFIED ELECTRODES IN THE PRESENCE AND ABSENCE OF THIOUREA AND ETHYLENETHIOUREA AS INHIBITORS
    ADEYOJU, O
    IWUOHA, EI
    SMYTH, MR
    ANALYTICA CHIMICA ACTA, 1995, 305 (1-3) : 57 - 64
  • [4] Peroxidase-modified electrodes: Fundamentals and application
    Ruzgas, T
    Csoregi, E
    Emneus, J
    Gorton, L
    MarkoVarga, G
    ANALYTICA CHIMICA ACTA, 1996, 330 (2-3) : 123 - 138
  • [5] Peroxidase-modified electrodes: Fundamentals and application
    Ruzgas, T.
    Csoeregi, E.
    Emneus, J.
    Gorton, L.
    Analytica Chimica Acta, 330 (2-3):
  • [6] Amperometric detection of peroxides using peroxidase and porphyrin biomimetic modified electrodes
    Baldini, E
    Dall'Orto, VC
    Danilowicz, C
    Rezzano, I
    Calvo, EJ
    ELECTROANALYSIS, 2002, 14 (17) : 1157 - 1164
  • [7] Peroxidase-modified carbon paste microelectrode as amperometric FI-detector for peroxides in partial aqueous media
    Popescu, IC
    Csoregi, E
    Gorton, L
    ELECTROANALYSIS, 1996, 8 (11) : 1014 - 1019
  • [8] ELECTROCATALYSIS AND AMPEROMETRIC DETECTION OF ORGANIC PEROXIDES AT MODIFIED CARBON-PASTE ELECTRODES
    WANG, J
    ANGNES, L
    LIANG, C
    EVANS, O
    TALANTA, 1991, 38 (10) : 1077 - 1081
  • [9] Phytase immobilization on modified electrodes for amperometric biosensing
    Moraes, Marli L.
    Oliveira, Osvaldo N.
    Rodrigues Filho, Ubirajara P.
    Ferreira, Marystela
    SENSORS AND ACTUATORS B-CHEMICAL, 2008, 131 (01) : 210 - 215
  • [10] KINETIC CHARACTERIZATION OF THE EFFECTS OF ORGANIC-SOLVENTS ON THE PERFORMANCE OF A PEROXIDASE-MODIFIED ELECTRODE IN DETECTING PEROXIDES, THIOUREA AND ETHYLENETHIOUREA
    ADEYOJU, O
    IWUOHA, EI
    SMYTH, MR
    ELECTROANALYSIS, 1995, 7 (10) : 924 - 929