QUALITY ASSURANCE IN STEREOTAXIC RADIOSURGERY USING A STANDARD LINEAR-ACCELERATOR

被引:59
|
作者
TSAI, JS
BUCK, BA
SVENSSON, GK
ALEXANDER, E
CHENG, CW
MANNARINO, EG
LOEFFLER, JS
机构
[1] HARVARD UNIV,SCH MED,DEPT SURG NEUROSURG & RADIAT THERAPY,BOSTON,MA 02115
[2] CHILDRENS HOSP MED CTR,BRIGHAM & WOMENS HOSP,NEUROSURG SERV,STEREOTACT RADIOSURG PROGRAM,BOSTON,MA 02115
关键词
QUALITY ASSURANCE; LINEAR ACCELERATOR; STEREOTAXIC RADIOSURGERY;
D O I
10.1016/0360-3016(91)90694-Y
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Methods have recently been developed for using standard linear accelerators to perform stereotactic radiosurgery. The accuracy necessary to perform this procedure requires an intensive quality assurance program to encompass all aspects of dose calibration and mechanical integrity of the treatment unit, the treatment planning process, and treatment delivery. The programs developed at the Joint Center for Radiation Therapy (JCRT) include testing of the linear accelerator and the stereotactic system, cross checking of the treatment planning process, and a quality assurance check list of the treatment delivery procedure. This report outlines in detail the quality assurance program currently in use at the JCRT.
引用
收藏
页码:737 / 748
页数:12
相关论文
共 50 条
  • [1] DYNAMIC STEREOTAXIC RADIOSURGERY USING A LINEAR-ACCELERATOR
    WORTHINGTON, C
    JENRETTE, JM
    FENN, JO
    FRYE, GD
    WISE, JD
    STARR, CW
    NELSON, SJ
    SCHOER, RC
    MILLER, R
    CURE, J
    CUDDY, BG
    TOTARO, SD
    WEICK, AJ
    GEILFUSS, CJ
    [J]. SOUTHERN MEDICAL JOURNAL, 1991, 84 (11) : 1327 - 1333
  • [2] STEREOTAXIC RADIOSURGERY UTILIZING A LINEAR-ACCELERATOR
    COLOMBO, F
    BENEDETTI, A
    POZZA, F
    ZANARDO, A
    AVANZO, RC
    CHIEREGO, G
    MARCHETTI, C
    [J]. APPLIED NEUROPHYSIOLOGY, 1985, 48 (1-6) : 133 - 145
  • [3] STEREOTAXIC RADIOSURGERY OF THE BRAIN USING A STANDARD LINEAR-ACCELERATOR - A STUDY OF EARLY AND LATE EFFECTS
    LOEFFLER, JS
    SIDDON, RL
    WEN, PY
    NEDZI, LA
    ALEXANDER, E
    [J]. RADIOTHERAPY AND ONCOLOGY, 1990, 17 (04) : 311 - 321
  • [4] CRITIQUE OF STEREOTAXIC RADIOSURGERY FOR INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS USING A STANDARD LINEAR-ACCELERATOR
    WOLLIN, M
    KURUVILLA, A
    KAGAN, AR
    OLCH, A
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1535 - 1536
  • [5] METHODOLOGY FOR STEREOTAXIC RADIOSURGERY OF THE BRAIN WITH A LINEAR-ACCELERATOR
    OLIVIER, A
    PODGORSAK, E
    HAZEL, J
    PLA, M
    DELOTBINIERE, A
    PIKE, B
    PETERS, T
    BERTRAND, G
    [J]. CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 1987, 14 (02) : 223 - 224
  • [6] CRITIQUE OF STEREOTAXIC RADIOSURGERY FOR INTRACRANIAL ARTERIOVENOUS-MALFORMATIONS USING A STANDARD LINEAR-ACCELERATOR - RESPONSE
    LOEFFLER, JS
    ALEXANDER, E
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1990, 18 (06): : 1536 - 1536
  • [7] ALGORITHM FOR DOSIMETRY OF MULTIARC LINEAR-ACCELERATOR STEREOTAXIC RADIOSURGERY
    LUXTON, G
    JOZSEF, G
    ASTRAHAN, MA
    [J]. MEDICAL PHYSICS, 1991, 18 (06) : 1211 - 1221
  • [8] TREATMENT PLANNING OPTIMIZATION FOR MULTIPLE ARCS STEREOTAXIC RADIOSURGERY USING A LINEAR-ACCELERATOR
    LAM, CF
    ZHU, JG
    PENN, JO
    JENRETTE, JM
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (03): : 647 - 657
  • [9] A SYSTEM FOR STEREOTAXIC RADIOSURGERY WITH A LINEAR-ACCELERATOR AND ITS PERFORMANCE EVALUATION
    LUTZ, W
    WINSTON, K
    MALEKI, N
    [J]. MEDICAL PHYSICS, 1986, 13 (04) : 611 - 611
  • [10] RADIOSURGERY WITH THE LINEAR-ACCELERATOR
    PATIL, AA
    [J]. NEUROSURGERY, 1989, 25 (01) : 143 - 143