SIMULATED SEISMIC-LOAD TESTS ON FULL-SCALE 5-STORY MASONRY BUILDING

被引:13
|
作者
SEIBLE, F [1 ]
HEGEMIER, GA [1 ]
IGARASHI, A [1 ]
KINGSLEY, GR [1 ]
机构
[1] UNIV CALIF SAN DIEGO,DEPT MECH & ENGN SCI,LA JOLLA,CA 92093
来源
JOURNAL OF STRUCTURAL ENGINEERING-ASCE | 1994年 / 120卷 / 03期
关键词
D O I
10.1061/(ASCE)0733-9445(1994)120:3(903)
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The first U.S. full-scale five-story building test under simulated seismic loads was conducted at the University of California, San Diego. The full-scale reinforced masonry (RM) research building consisted of coupled, flanged fully grouted concrete masonry walls and precast prestressed hollow-core plank floors with reinforced-concrete topping. The seismic-simulation tests were conducted under the direction of the Technical Coordinating Committee for Masonry Research (TCCMAR) to validate new analysis and design models for masonry buildings in seismic zones. The complete seismic simulation testing of the five-story structural wall building under recorded earthquake ground-motion segments was possible through soft coupling between the loading system and the stiff test strUCture, and improvements to the on-line actuator-control algorithm as part of the implicit time-integration scheme. The development and implementation of the generated sequential displacement (GSD) procedure for the experimental multidegree-of-freedom seismic-load simulation is described and illustrated by detailed examples of responses.
引用
收藏
页码:903 / 924
页数:22
相关论文
共 50 条
  • [1] Simulated seismic-load tests on full-scale five-story masonry building
    Seible, F.
    Hegemier, G.A.
    Igarashi, A.
    Kingsley, G.R.
    [J]. Journal of structural engineering New York, N.Y., 1994, 120 (03): : 903 - 924
  • [2] SEISMIC RESPONSE OF FULL-SCALE 5-STORY REINFORCED-MASONRY BUILDING
    SEIBLE, F
    PRIESTLEY, MJN
    KINGSLEY, GR
    KURKCHUBASCHE, AG
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 1994, 120 (03): : 925 - 946
  • [3] 3-D shake table tests on full-scale 5-story steel building with viscous dampers
    Kasai, Kazuhiko
    Yamagiwa, Hajime
    Nishijima, Masato
    Baba, Yuki
    Ito, Hiroshi
    Hikino, Tsuyoshi
    Ooki, Yoji
    [J]. Journal of Structural and Construction Engineering, 2014, 79 (695): : 47 - 56
  • [4] 3-D shake table tests on full-scale 5-story steel building with oil dampers
    [J]. 1999, Architectural Institute of Japan (78):
  • [5] Study of Vertical Load Distribution in Full-Scale Four-Story Masonry Building
    Andolfato, R. P.
    Ramalho, M. A.
    Correa, M. R. S.
    Haach, V. G.
    [J]. ACI STRUCTURAL JOURNAL, 2014, 111 (03) : 685 - 691
  • [6] Performance of Exterior Precast Concrete Cladding Panels in NEES-TIPS/E∼Defense Tests on a Full-Scale 5-Story Building
    McMullin, Kurt M.
    Kamau-Devers, Kanotha
    [J]. STRUCTURES CONGRESS 2017: BUSINESS, PROFESSIONAL PRACTICE, EDUCATION, RESEARCH, AND DISASTER MANAGEMENT, 2017, : 209 - 219
  • [7] Seismic performance of a full-scale five-story masonry-infilled RC building subjected to substructured pseudodynamic tests
    Kallioras, Stylianos
    Pohoryles, Daniel A.
    Bournas, Dionysios
    Molina, Francisco Javier
    Pegon, Pierre
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (12): : 3649 - 3678
  • [8] Full-scale tests of passively-controlled 5-story steel building using E-Defense shake table Part 3: Full-scale tests for dampers and beam-column subassemblies
    Ooki, Y.
    Kasai, K.
    Motoyui, S.
    Kaneko, K.
    Kajiwara, K.
    Hikino, T.
    [J]. STESSA 2009 - BEHAVIOUR OF STEEL STRUCTURES IN SEISMIC AREAS, 2009, : 93 - +
  • [9] Simulated seismic laboratory load testing of full-scale buildings
    Univ of California, San Diego, La Jolla, United States
    [J]. Earthquake Spectra, 1 (57-86):
  • [10] Testing of a full-scale unreinforced masonry building following seismic strengthening
    Moon, Franklin L.
    Yi, Tianyi
    Leon, Roberto T.
    Kahn, Lawrence F.
    [J]. JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2007, 133 (09): : 1215 - 1226