Nanostructured based Electrochemical Sensor for Voltammetric Determination of Ascorbic Acid in Pharmaceutical and Biological Samples

被引:0
|
作者
Beitollahi, Hadi [1 ]
Tajik, Somayeh [2 ,3 ]
Parvan, Hekmat [1 ]
Soltani, Hossein [4 ]
Akbari, Ali [5 ]
Asadi, Malek Hossein [6 ]
机构
[1] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Environm Dept, Kerman, Iran
[2] Shahid Bahonar Univ Kerman, Dept Chem, Kerman, Iran
[3] Shahid Bahonar Univ Kerman, Young Researchers Soc, Kerman, Iran
[4] Payame Noor Univ, Dept Chem, Tehran 193954697, Iran
[5] Univ Jiroft, Dept Chem, Jiroft, Iran
[6] Grad Univ Adv Technol, Inst Sci & High Technol & Environm Sci, Biotechnol Dept, Kerman, Iran
来源
关键词
Ascorbic acid; Carbon nanotube paste electrode; Modified electrode; voltammetry;
D O I
暂无
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A novel carbon paste electrode modified with carbon nanotubes and 5-amino-2', 4'-dimethoxy-biphenyl-2-ol (5ADMB) was fabricated. The electrochemical study of the modified electrode, as well as its efficiency for electrocatalytic oxidation of ascorbic acid, is described. Cyclic voltammetry was used to investigate the redox properties of this modified electrode at various scan rates. The apparent charge transfer rate constant, k(s), and transfer coefficient, a, for electron transfer between 5ADMB and carbon nanotubes paste electrode were calculated as 7.94 s(-1) and 0.5, respectively. The electrode was also employed to study the electrocatalytic oxidation of ascorbic acid, using cyclic voltammetry, chronoamperometry and square wave voltammetry as diagnostic techniques. It has been found that the oxidation of ascorbic acid at the surface of modified electrode occurs at a potential of about 250 mV less positive than that of an unmodified CPE. The diffusion coefficient, electron transfer coefficient, and heterogeneous rate constant, for oxidation of ascorbic acid at the modified electrode surface were also determined. Square wave voltammetry (SWV) exhibits a linear dynamic range from 1.0x10(-6) to 7.5x10(-4) M and a detection limit of 0.1 mu M for ascorbic acid. Finally this modified electrode was used for determination of ascorbic acid in real samples.
引用
收藏
页码:54 / 66
页数:13
相关论文
共 50 条
  • [1] Nanostructured Base Electrochemical Sensor for Simultaneous Quantification and Voltammetric Studies of Levodopa and Carbidopa in Pharmaceutical Products and Biological Samples
    Beitollahi, Hadi
    Mostafavi, Mortaza
    ELECTROANALYSIS, 2014, 26 (05) : 1090 - 1098
  • [2] A nanostructure-based electrochemical sensor for square wave voltammetric determination of N-acetylcysteine in pharmaceutical and biological samples
    Arabali, Vahid
    Karimi-Maleh, Hassan
    Beitollahi, Hadi
    Moradi, Reza
    Ebrahimi, Mahmoud
    Ahmar, Hamid
    IONICS, 2015, 21 (04) : 1153 - 1161
  • [3] A nanostructure-based electrochemical sensor for square wave voltammetric determination of N-acetylcysteine in pharmaceutical and biological samples
    Vahid Arabali
    Hassan Karimi-Maleh
    Hadi Beitollahi
    Reza Moradi
    Mahmoud Ebrahimi
    Hamid Ahmar
    Ionics, 2015, 21 : 1153 - 1161
  • [4] Colorimetric determination of ascorbic acid in pharmaceutical preparations and biological samples
    Arya, SP
    Mahajan, M
    MIKROCHIMICA ACTA, 1997, 127 (1-2) : 45 - 49
  • [5] Colorimetric determination of ascorbic acid in pharmaceutical preparations and biological samples
    Satya P. Arya
    Meenakshi Mahajan
    Microchimica Acta, 1997, 127 : 45 - 49
  • [6] Development of an electrochemical sensor for the quantification of ascorbic acid and acetaminophen in pharmaceutical samples
    Gutierrez, Alejandro
    Ramirez-Ledesma, Maria Guadalupe
    Rivas, Gustavo A.
    Luna-Barcenas, Gabriel
    Escalona-Villalpando, Ricardo A.
    Ledesma-Garcia, Janet
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2024, 249
  • [7] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Beitollahi, Hadi
    Mohadesi, Alireza
    Mostafavi, Mortaza
    Karimi-Maleh, Hassan
    Baghayeri, Mehdi
    Akbari, Ali
    IONICS, 2014, 20 (05) : 729 - 737
  • [8] Voltammetric sensor for simultaneous determination of ascorbic acid, acetaminophen, and tryptophan in pharmaceutical products
    Hadi Beitollahi
    Alireza Mohadesi
    Mortaza Mostafavi
    Hassan Karimi-Maleh
    Mehdi Baghayeri
    Ali Akbari
    Ionics, 2014, 20 : 729 - 737
  • [9] An Electrochemical Nanosensor for Simultaneous Voltammetric Determination of Ascorbic Acid and Sudan I in Food Samples
    Karimi-Maleh, Hassan
    Moazampour, Mahbobeh
    Yoosefian, Mehdi
    Sanati, Afsaneh L.
    Tahernejad-Javazmi, Fahimeh
    Mahani, Mohamad
    FOOD ANALYTICAL METHODS, 2014, 7 (10) : 2169 - 2176
  • [10] An Electrochemical Nanosensor for Simultaneous Voltammetric Determination of Ascorbic Acid and Sudan I in Food Samples
    Hassan Karimi-Maleh
    Mahbobeh Moazampour
    Mehdi Yoosefian
    Afsaneh L. Sanati
    Fahimeh Tahernejad-Javazmi
    Mohamad Mahani
    Food Analytical Methods, 2014, 7 : 2169 - 2176