PASSIVE TWO-PHASE THERMOSYPHON LOOP COOLING SYSTEM FOR HIGH-HEAT-FLUX SERVERS

被引:7
|
作者
Lamaison, N. [1 ]
Marcinichen, J. B. [1 ]
Szczukiewicz, S. [1 ]
Thome, J. R. [1 ]
Beucher, P. [2 ]
机构
[1] Ecole Polytech Fed Lausanne, Lab Heat & Mass Transfer LTCM, Stn 9, CH-1015 Lausanne, Switzerland
[2] Wolverine Tube Inc, MicroCool Div, Decatur, AL 35601 USA
关键词
servers; datacenter; thermosyphon cooling; passive cooling; two-phase flow; safety factor; monetary savings; payback period; net benefit per year;
D O I
10.1615/InterfacPhenomHeatTransfer.2016015637
中图分类号
O414.1 [热力学];
学科分类号
摘要
The main aim of the current paper is to demonstrate the capability of a two-phase closed thermosyphon loop system to cool down a contemporary datacenter rack, passively cooling the entire rack, including its numerous servers. The effects on the cooling loop performance with respect to the server orientation, microevaporator design, riser and downcomer diameters, working fluid, and approach temperature at the condenser have been modeled and simulated. The influence of the thermosyphon height (here from 5-20 cm with a horizontally or vertically oriented server) on the driving force that guarantees the system operation while simultaneously fulfilling the critical heat flux (CHF) criterion also has been examined. In summary, the thermosyphon height was found to be the most significant design parameter. For the conditions simulated, in terms of CHF, the 10-cm-high thermosyphon was the most advantageous system design with a minimum safety factor of 1.6 relative to the imposed heat flux of 80 Wcm(-2). Additionally, a case study including an overhead water-cooled heat exchanger to extract heat from the thermosyphon loop has been developed, and then the entire rack cooling system has been evaluated in terms of cost savings, payback period, and net benefit per year. This approximate study provides a general understanding of how the datacenter cooling infrastructure directly impacts the operating budget as well as influencing the thermal/hydraulic operation, performance, and reliability of the datacenter. Finally, the study shows that the passive two-phase closed-loop thermosyphon cooling system is a potentially economically sound technology to cool high-heat-flux servers of datacenters.
引用
收藏
页码:369 / 391
页数:23
相关论文
共 50 条
  • [1] PASSIVE THERMOSYPHON COOLING SYSTEM FOR HIGH HEAT FLUX SERVERS
    Szczukiewicz, Sylwia
    Lamaison, Nicolas
    Marcinichen, Jackson B.
    Thome, John R.
    Beucher, Peter J.
    [J]. INTERNATIONAL TECHNICAL CONFERENCE AND EXHIBITION ON PACKAGING AND INTEGRATION OF ELECTRONIC AND PHOTONIC MICROSYSTEMS, 2015, VOL 3, 2015,
  • [2] Numerical simulation of the evaporator in two-phase thermosyphon loop for passive containment cooling system
    Yin, Xuan
    Wu, Xiaotian
    Zhou, Shaofei
    Zhu, Xixi
    Wang, Naihua
    [J]. ANNALS OF NUCLEAR ENERGY, 2023, 180
  • [3] Experimental investigation of two-phase thermosyphon loop for passive containment cooling
    Yin, Xuan
    Hu, Jian
    Chi, Xiangyu
    Li, Yaru
    Nan, Zezhao
    Wang, Naihua
    [J]. APPLIED THERMAL ENGINEERING, 2021, 184
  • [4] A hierarchical manifold microchannel heat sink array for high-heat-flux two-phase cooling of electronics
    Drummond, Kevin P.
    Back, Doosan
    Sinanis, Michael D.
    Janes, David B.
    Peroulis, Dimitrios
    Weibel, Justin A.
    Garimella, Suresh V.
    [J]. INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2018, 117 : 319 - 330
  • [5] Low-Temperature Two-Phase Microchannel Cooling for High-Heat-Flux Thermal Management of Defense Electronics
    Lee, Jaeseon
    Mudawar, Issam
    [J]. IEEE TRANSACTIONS ON COMPONENTS AND PACKAGING TECHNOLOGIES, 2009, 32 (02): : 453 - 465
  • [6] Two-phase refrigerant flow in the evaporator of a stirling cooling system with a thermosyphon loop
    Celik, Serdar
    Ekren, Orhan
    [J]. EXPERIMENTAL HEAT TRANSFER, 2020, 33 (04) : 305 - 317
  • [7] AN EXPERIMENTAL STUDY OF CLOSED LOOP TWO-PHASE THERMOSYPHON FOR SPENT FUEL POOL PASSIVE COOLING
    Wang, Minglu
    Zheng, Mingguang
    Ye, Cheng
    Qiu, Zhongming
    Xiong, Zhenqin
    [J]. PROCEEDINGS OF THE 24TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2016, VOL 3, 2016,
  • [8] Single-phase and two-phase hybrid cooling schemes for high-heat-flux thermal management of defense electronics
    Sung, Myung Ki
    Mudawar, Issam
    [J]. 2008 11TH IEEE INTERSOCIETY CONFERENCE ON THERMAL AND THERMOMECHANICAL PHENOMENA IN ELECTRONIC SYSTEMS, VOLS 1-3, 2008, : 121 - +
  • [9] Single-Phase and Two-Phase Hybrid Cooling Schemes for High-Heat-Flux Thermal Management of Defense Electronics
    Sung, Myung Ki
    Mudawar, Issam
    [J]. JOURNAL OF ELECTRONIC PACKAGING, 2009, 131 (02) : 0210131 - 02101310
  • [10] Two-phase thermosyphon loop for cooling outdoor telecommunication equipments
    Samba, Ahmadou
    Louahlia-Gualous, Hasna
    Le Masson, Stephane
    Noerterhaeuser, David
    [J]. APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 1351 - 1360