ABERRATION ANALYSIS OF WIEN FILTERS AND DESIGN OF AN ELECTRON ENERGY-SELECTIVE IMAGING-SYSTEM

被引:10
|
作者
LIU, XD
TANG, TT
机构
[1] Xi'an JiaoTong University, Xi'an
关键词
D O I
10.1016/0168-9002(95)00262-6
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Focusing-imaging, dispersive and aberration performances of Wien filters have been studied. The first order chromatic aberration and second order geometric aberration coefficients for Wien filters not satisfying the stigmatic focusing condition have been derived. An aberration correction method has been proposed using the symmetry of fields and fundamental paraxial rays to correct all the second order aberrations. A design of an energy-selective imaging system using the symmetry and consisting of four identical cascading Wien filters with an octupole electrical magnetic structure is described, and the imaging properties of the energy-selective imaging system has been computed.
引用
收藏
页码:254 / 260
页数:7
相关论文
共 50 条
  • [1] Conceptual design of a gamma-to-electron energy-selective imaging system for high-flux MeV gamma rays
    Zhang, Changqing
    Sheng, Liang
    Song, Zhaohui
    Da, Tianxing
    Li, Haoqing
    Duan, Baojun
    Li, Yang
    Hei, Dongwei
    Wang, Qunshu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1068
  • [2] The energy-selective option in neutron imaging
    Lehmann, E. H.
    Frei, G.
    Vontobel, P.
    Josic, L.
    Kardjilov, N.
    Hilger, A.
    Kockelmann, W.
    Steuwer, A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 603 (03): : 429 - 438
  • [3] CHROMATIC ABERRATION OF THE SELFOC LENS AS AN IMAGING-SYSTEM
    NISHIZAWA, K
    APPLIED OPTICS, 1980, 19 (07): : 1052 - 1055
  • [4] Isotropic and energy-selective electron cloaks on graphene
    Liao, Bolin
    Zebarjadi, Mona
    Esfarjani, Keivan
    Chen, Gang
    PHYSICAL REVIEW B, 2013, 88 (15):
  • [5] ENERGY-SELECTIVE SESD IMAGING UTILIZING A CMA
    LARSON, LA
    SORIA, F
    POPPA, H
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1980, 17 (06): : 1364 - 1366
  • [6] USING DYES AND FILTERS IN A FLUORESCENT IMAGING-SYSTEM
    BECHTOL, KB
    HANZEL, DK
    LIANG, BC
    AMERICAN BIOTECHNOLOGY LABORATORY, 1994, 12 (13): : 8 - 10
  • [7] Energy-Selective X-Ray Ghost Imaging
    He, Yu-Hang
    Zhang, Ai-Xin
    Yu, Wen-Kai
    Chen, Li-Ming
    Wu, Ling-An
    CHINESE PHYSICS LETTERS, 2020, 37 (04)
  • [8] Energy-Selective X-Ray Ghost Imaging
    何雨航
    张艾昕
    俞文凯
    陈黎明
    吴令安
    Chinese Physics Letters, 2020, 37 (04) : 86 - 89
  • [9] Energy-selective neutron transmission imaging at a pulsed source
    Kockelmann, W.
    Frei, G.
    Lehmann, E. H.
    Vontobel, P.
    Santisteban, J. R.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 578 (02): : 421 - 434
  • [10] Energy-Selective X-Ray Ghost Imaging
    何雨航
    张艾昕
    俞文凯
    陈黎明
    吴令安
    Chinese Physics Letters, 2020, (04) : 86 - 89