Initial Experience With Robotic Epicardial Off-Pump Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation

被引:0
|
作者
Casselman, Filip [1 ]
Bakir, Ihsan [1 ]
Brugada, Pedro [2 ]
Geelen, Peter [2 ]
Wellens, Francis [1 ]
Van Praet, Frank [1 ]
Gegrieck, Ivan [1 ]
Vermeulen, Yvette [1 ]
Vanermen, Hugo [1 ]
机构
[1] OLV Clin, Cardiovasc & Thorac Surg Dept, Moorselbaan 164, B-9300 Aalst, Belgium
[2] OLV Clin, Cardiovasc Res & Teaching Inst, Aalst, Belgium
关键词
Minimally invasive; Robotic; Atrial fibrillation; Pulmonary vein isolation; Microwave;
D O I
10.1097/01.imi.0000235467.09577.65
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To evaluate the feasibility and results of isolated endoscopic pulmonary vein isolation for paroxysmal atrial fibrillation using robotics. Methods: Between November 2004 and December 2005, 13 patients (38.5% female) underwent robotic pulmonary vein isolation at our institution. Mean age was 46.8 +/- 8.4 years and mean preoperative duration of atrial fibrillation was 52.7 +/- 31.5 months. Indication for surgery was symptomatic drug-refractory paroxysmal atrial fibrillation or recurrence after percutaneous treatment (n = 3). Mean preoperative left atrial dimension was 38.5 +/- 6.9 mm. The surgical procedure was performed off-pump as an isolated right chest approach. All procedures were performed using the Flex 10 microwave ablator (Guidant, Indianapolis, IN), which was positioned from the right side through the transverse sinus and around the 4 pulmonary veins. Postoperative drug regimen included sotalol and Coumadin. Mean follow-up was 8.5 +/- 3.4 months. Results: The procedure was successful in 11 patients. One patient needed conversion to median sternotomy for right pulmonary artery bleeding and a second patient had severe transverse sinus adhesions requiring conversion to a bilateral video-assisted small thoracotomy approach. No other morbidity occurred. Mean procedure time in successful cases was 2.7 +/- 0.8 hours (range 1.7 to 4 hours). Permanent sinus rhythm was successfully restored in 10 of 13 patients (76.9% beyond 6 months). Nonsuccessful patients had markedly reduced symptoms and frequency of events. One patient required a left and another a right atrial flutter ablation during follow-up. Conclusions: Robotic pulmonary vein isolation is a feasible procedure that has the potential to become a valid option in the treatment of paroxysmal atrial fibrillation.
引用
收藏
页码:247 / 250
页数:4
相关论文
共 50 条
  • [1] Minimally invasive off-pump pulmonary vein isolation to treat paroxysmal atrial fibrillation
    Vicol, C
    Eifert, S
    Kur, F
    Reichart, B
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (03): : 176 - 178
  • [2] Initial experience of video-assisted epicardial pulmonary vein isolation off-pump and ablation of ganglionic plexi in patients with atrial fibrillation
    Blomstrom, P.
    Nilsson, L.
    Myrdal, G.
    Blomstrom-Lundqvist, C.
    [J]. EUROPEAN HEART JOURNAL, 2006, 27 : 273 - 273
  • [3] Prandial atrial fibrillation: Off-pump pulmonary vein isolation with hiatal hernia repair
    Gillinov, AM
    Rice, TW
    [J]. ANNALS OF THORACIC SURGERY, 2004, 78 (05): : 1836 - 1838
  • [4] Technical tips for concomitant off-pump epicardial pulmonary vein isolation
    Totsugawa T.
    Kuinose M.
    Yoshitaka H.
    Tsushima Y.
    Ishida A.
    [J]. General Thoracic and Cardiovascular Surgery, 2011, 59 (4) : 307 - 309
  • [5] PULMONARY VEIN ISOLATION FOR PAROXYSMAL ATRIAL FIBRILLATION USING CRYOBALLOON: THE INITIAL CANADIAN EXPERIENCE
    Mokranl, B.
    Champagne, J.
    Phillppon, F.
    O'Hara, G.
    Naults, I.
    Zannad, N.
    Molln, F.
    Blier, L.
    Sarrazin, J.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2011, 27 (05) : S187 - S188
  • [6] Initial experience with the Mesh catheter for pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Mansour, Moussa
    Forleo, Giovanni B.
    Pappalardo, Augusto
    Heist, E. Kevin
    Avella, Andrea
    Laurenzi, Francesco
    De Girolamo, Piergiuseppe
    Bencardino, Gianluigi
    Dello Russo, Antonio
    Mantica, Massimo
    Ruskin, Jeremy N.
    Tondo, Claudio
    [J]. HEART RHYTHM, 2008, 5 (11) : 1510 - 1516
  • [7] How Does Successful Off-Pump Pulmonary Vein Isolation for Paroxysmal Atrial Fibrillation Influence Heart Rate Variability and Autonomic Activity?
    Suwalski, Grzegorz
    Suwalski, Piotr
    Kalisnik, Jurij M.
    Sledz, Mariusz
    Switaj, Julita
    Czachor, Marcin
    Gersak, Borut
    Suwalski, Kazimierz B.
    [J]. INNOVATIONS-TECHNOLOGY AND TECHNIQUES IN CARDIOTHORACIC AND VASCULAR SURGERY, 2008, 3 (01) : 1 - 6
  • [8] Epicardial off-pump pulmonary vein isolation and vagal denervation improve long-term outcome and quality of life in patients with atrial fibrillation
    Bagge, Louise
    Blomstrom, Per
    Nilsson, Leif
    Einarsson, Gunnar Myrdal
    Jideus, Lena
    Blomstrom-Lundqvist, Carina
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2009, 137 (05): : 1265 - 1271
  • [9] Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    Oral, H
    Knight, BP
    Tada, H
    Özaydin, M
    Chugh, A
    Hassan, S
    Scharf, C
    Lai, SWK
    Greenstein, R
    Pelosi, F
    Strickberger, SA
    Morady, F
    [J]. CIRCULATION, 2002, 105 (09) : 1077 - 1081
  • [10] Treatment of paroxysmal atrial fibrillation by pulmonary vein isolation
    Morady, F
    [J]. CIRCULATION JOURNAL, 2003, 67 (07) : 567 - 571