IN-VITRO BIOMECHANICAL COMPARISON OF SOLID AND TUBULAR INTERLOCKING NAILS IN NEONATAL BOVINE FEMURS

被引:18
|
作者
TROSTLE, SS
WILSON, DG
DUELAND, RT
MARKEL, MD
机构
[1] UNIV WISCONSIN,SCH VET MED,DEPT SURG SCI,COMPART ORTHOPAED RES LAB,MADISON,WI 53706
[2] MARION DUPONT SCOTT EQUINE MED CTR,LEESBURG,VA
关键词
D O I
10.1111/j.1532-950X.1995.tb01324.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
This study biomechanically evaluates solid and tubular interlocking nails in bovine neonatal femurs. Paired femurs from 40 neonatal dairy calves were obtained for mechanical testing. Intact femurs and four combinations of experimentally manipulated femurs (intact or ostectomized femurs with either a solid or tubular interlocking nail) were tested in craniocaudal and lateromedial bending, eccentric axial compression, and external torsion to evaluate composite rigidity, local/gap stiffness, and load to failure (compression and torsion only). In torsional composite rigidity, femurs with tubular interlocking nails were more compliant than intact femurs or intact femurs with solid interlocking nails (P<.001). Ostectomized femurs with solid interlocking nails were similar to intact femurs with tubular interlocking nails. Within femurs with tubular interlocking nails, ostectomized femurs were more compliant than intact femurs (P<.0001). In craniocaudal and lateromedial bending rigidity, ostectomized femurs were more compliant than intact femurs, regardless of interlocking nail type (P<.001). Within ostectomized femurs, tubular interlocking nails were more compliant than solid interlocking nails in craniocaudal bending (P<.05) and there was a similar trend in lateromedial bending (P=.06). In eccentric axial compression, local/gap stiffness was significantly greater in intact femurs compared with intact femurs with solid (48% of intact bone) or tubular (45% of intact bone) interlocking nails and ostectomized femurs with solid (18% of intact bone) or tubular (11% of intact bone) interlocking nails (P<.0001). In torsional testing, local/gap stiffness was not significantly different between intact femurs and intact femurs with interlocking nails, but was significantly lower in ostectomized femurs with solid (2% of intact bone) and tubular (0.2% of intact bone) interlocking nails (P<.0001). In torsional and compressive failure testing, plastic deformation of the tubular interlocking nail occurred at the unoccupied screw hole at the ostectomy site before bone failure. Interlocking nails should be considered as an optional repair method for neonatal bovine femoral fractures. Until the actual physiological loading characteristics of neonatal calf femurs are measured, it is uncertain whether solid or tubular interlocking nails tested in this study will provide sufficient strength and stiffness to stabilize neonatal bovine femoral fractures and facilitate healing. (C)Copyright 1995 by The American College of Veterinary Surgeons
引用
收藏
页码:235 / 243
页数:9
相关论文
共 50 条
  • [1] Biomechanical comparison of different fixations of femur-interlocking-nails
    Widjaja, W
    Hartung, C
    CLINICAL BIOMECHANICS, 2001, 16 (08) : 702 - 705
  • [2] BIOMECHANICAL COMPARISON OF SLOTTED AND NONSLOTTED INTERLOCKING NAILS IN DISTAL FEMORAL-SHAFT FRACTURES
    COVEY, DC
    SAHA, S
    LIPKA, JM
    ALBRIGHT, JA
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1990, (252) : 246 - 251
  • [3] An in vitro biomechanical comparison between bone plate and interlocking nail -: 3-D interfragmentary motion and bone strain analysis in ostectomized canine femurs
    Bernardé, A
    Diop, A
    Maurel, N
    Viguier, E
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2002, 15 (02) : 57 - 66
  • [4] AN IN-VITRO BIOMECHANICAL INVESTIGATION OF AN INTERLOCKING NAIL FOR FIXATION OF DIAPHYSEAL TIBIAL FRACTURES IN ADULT HORSES
    MCDUFFEE, LA
    STOVER, SM
    TAYLOR, KT
    LES, CM
    VETERINARY SURGERY, 1994, 23 (04) : 219 - 230
  • [5] TRANSENDOTHELIAL MIGRATION OF NEONATAL AND ADULT BOVINE NEUTROPHILS IN-VITRO
    BOCHSLER, PN
    NEILSEN, NR
    SLAUSON, DO
    JOURNAL OF LEUKOCYTE BIOLOGY, 1994, 55 (01) : 43 - 49
  • [6] In-vitro evaluation of fatigue failure of locking screws in solid tibial nails
    C. Gäbler
    E. K. Tschegg
    M. Greitbauer
    S. Stanzl-Tschegg
    G. E. Wozasek
    W. Laube
    V. Vécsei
    Der Unfallchirurg, 1999, 102 : 29 - 34
  • [7] In-vitro evaluation of fatigue failure of locking screws in solid tibial nails
    Gäbler, C
    Tschegg, EK
    Greitbauer, M
    Stanzl-Tschegg, S
    Wozasek, GE
    Laube, W
    Vécsei, V
    UNFALLCHIRURG, 1999, 102 (01): : 29 - 34
  • [8] In vitro biomechanical comparison of a newly designed interlocking nail system to a standard DCP
    Brueckner, M.
    Unger, M.
    Spies, M.
    TIERAERZTLICHE PRAXIS AUSGABE KLEINTIERE HEIMTIERE, 2014, 42 (02): : 79 - 87
  • [9] IN-VITRO COMPARISON OF ARTIFICIAL AND BOVINE SURFACTANT - IMMUNOLOGICAL PROPERTIES
    BRUNE, T
    BRINKMANN, S
    LUETKEMEYER, K
    RABE, H
    HENTSCHEL, R
    JORCH, G
    PEDIATRIC RESEARCH, 1995, 38 (03) : 427 - 427
  • [10] In-vitro comparison of biomechanical efficiency of three cannulated screws for arthrodesis of the hindfoot
    Huber, Wolfgang O.
    Reihsner, Roland
    Trieb, Klemens
    Wanivenhaus, Axel Hugo
    Beer, Rudolf
    FOOT & ANKLE INTERNATIONAL, 2008, 29 (02) : 225 - 230