A case study of replacement of external post-tensioning cables

被引:2
|
作者
Rammer, Yves [1 ]
Espion, Bernard [1 ]
机构
[1] Univ Libre Bruxelles, Dept Bldg Architecture & Town Planning, Brussels, Belgium
关键词
bridges; concrete structures; rehabilitation; reclamation & renovation;
D O I
10.1680/bren.13.00019
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents a case study of an economical intervention on an early prestressed post-tensioned concrete structure. Built in 1960, a 60 m span concrete railway bridge at Clabecq in Belgium had a simply supported two-cell box girder. It was post-tensioned with one of the last applications in Belgium of the Blaton-Magnel 'sandwich' system. The cables were external to the concrete and only protected from corrosion by cement grout. Maintenance inspections in the 1990s revealed that corrosion of the tendons was so severe that the future safety of the bridge was compromised. The owner decided to replace all existing cables with new tendons placed in high-density polyethylene ducts, with each tendon composed of 15 monostrands. This paper describes the assessment of the existing structure, attempts to estimate the residual pre-stressing force and the design and implementation of the repair. It also discusses problems encountered and lessons learned.
引用
收藏
页码:183 / 192
页数:10
相关论文
共 50 条
  • [1] POST-TENSIONING
    HANUSCHAK, W
    [J]. CIVIL ENGINEERING, 1983, 53 (03): : 30 - 30
  • [2] External post-tensioning concrete pier caps
    Cook, SJ
    [J]. 14TH ANNUAL INTERNATIONAL BRIDGE CONFERENCE AND EXHIBITION - PROCEEDINGS, 1997, : 290 - 295
  • [3] Preliminary Study on the Design of Structures with a Responsive External Post-tensioning System
    Corral, Maria del Mar
    Todisco, Leonardo
    Corres, Hugo
    [J]. STRUCTURAL ENGINEERING INTERNATIONAL, 2021, 31 (03) : 368 - 375
  • [4] Effect of External Post-tensioning in Retrofitting of RC Beams
    Manisekar R.
    [J]. Journal of The Institution of Engineers (India): Series A, 2018, 99 (3) : 495 - 501
  • [5] The application of external post-tensioning system to a damage masonry arch
    Zampieri, Paolo
    Piazzon, Riccardo
    Ferroni, Riccardo
    Pellegrino, Carlo
    [J]. XIX ANIDIS CONFERENCE, SEISMIC ENGINEERING IN ITALY, 2023, 44 : 605 - 609
  • [6] Experimental Study of Bleed Countermeasures for Post-Tensioning
    Zhou, Yongzheng
    Zhu, Eryu
    [J]. ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (08) : 1273 - 1285
  • [7] GROUTING POST-TENSIONING DUCTS
    不详
    [J]. CONCRETE CONSTRUCTION, 1983, 28 (04): : 337 - 339
  • [8] Retrofitting of Distressed Post-tensioned Concrete Members by External Post-tensioning
    Manisekar R.
    Saravana Kumar K.
    [J]. Journal of The Institution of Engineers (India): Series A, 2023, 104 (03) : 675 - 683
  • [9] GROUTING OF POST-TENSIONING TENDONS
    SCHUPACK, M
    [J]. CIVIL ENGINEERING, 1978, 48 (03): : 72 - 73
  • [10] Bond of post-tensioning strands in case of grouting defects
    Ferretti, Daniele
    Pagliari, Federico
    Belletti, Beatrice
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2024, 426