On-chip Mach-Zehnder interferometer for OCT systems

被引:11
|
作者
van Leeuwen, Ton G. [1 ]
Akca, Imran B. [1 ,2 ]
Angelou, Nikolaos [1 ]
Weiss, Nicolas [1 ]
Hoekman, Marcel [3 ]
Leinse, Arne [3 ]
Heideman, Rene G. [3 ]
机构
[1] Univ Amsterdam, Acad Med Ctr, Biomed Engn & Phys, POB 22700, NL-1100 DE Amsterdam, Netherlands
[2] Vrije Univ Amsterdam, Dept Phys & Astron, Inst Lasers Life & Biophoton Amsterdam, De Boelelaan, Amsterdam, Netherlands
[3] LioniX Int BV, Enschede Al, Netherlands
关键词
Mach-Zehnder interferometer; on-chip; optical coherence tomography; silicon nitride;
D O I
10.1515/aot-2017-0061
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
By using integrated optics, it is possible to reduce the size and cost of a bulky optical coherence tomography (OCT) system. One of the OCT components that can be implemented on-chip is the interferometer. In this work, we present the design and characterization of a Mach-Zehnder interferometer consisting of the wavelength-independent splitters and an on-chip reference arm. The Si3N4 was chosen as the material platform as it can provide low losses while keeping the device size small. The device was characterized by using a home-built swept source OCT system. A sensitivity value of 83 dB, an axial resolution of 15.2 mu m (in air) and a depth range of 2.5 mm (in air) were all obtained.
引用
收藏
页码:103 / 106
页数:4
相关论文
共 50 条
  • [1] An On-Chip Mach-Zehnder Interferometer in the Microwave Regime
    Schuermans, Steven
    Simoen, Michael
    Sandberg, Martin
    Krantz, Philip
    Wilson, C. M.
    Delsing, Per
    [J]. IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2011, 21 (03) : 448 - 451
  • [2] Plasmonic Mach-Zehnder Interferometer for Ultrasensitive On-Chip Biosensing
    Gao, Yongkang
    Gan, Qiaoqiang
    Xin, Zheming
    Cheng, Xuanhong
    Bartoli, Filbert J.
    [J]. ACS NANO, 2011, 5 (12) : 9836 - 9844
  • [3] Polymer based Mach-Zehnder interferometer for on-chip applications
    Durisova, Jana
    Gaso, Peter
    Pudis, Dusan
    Figurova, Maria
    Kuzma, Anton
    [J]. 21ST CZECH-POLISH-SLOVAK OPTICAL CONFERENCE ON WAVE AND QUANTUM ASPECTS OF CONTEMPORARY OPTICS, 2018, 10976
  • [4] On-chip silicon Mach-Zehnder interferometer sensor for ultrasound detection
    Ouyang, Boling
    Li, Yanlu
    Kruidhof, Marten
    Horsten, Roland
    van Dongen, Koen W. A.
    Caro, Jacob
    [J]. OPTICS LETTERS, 2019, 44 (08) : 1928 - 1931
  • [5] On-Chip Loop-Terminated Mach-Zehnder Interferometer Gas Sensor
    El Shamy, Raghi S.
    Li, Xun
    ElRayany, Mohamed M.
    Sultan, Alaa
    Swillam, Mohamed A.
    [J]. 2022 PHOTONICS NORTH (PN), 2022,
  • [6] On-Chip Integrated Mid-Infrared GaAs/AlGaAs Mach-Zehnder Interferometer
    Sieger, Markus
    Balluff, Franz
    Wang, Xiaofeng
    Kirn, Seong-Soo
    Leidner, Lothar
    Gauglitz, Guenter
    Mizaikof, Boris
    [J]. ANALYTICAL CHEMISTRY, 2013, 85 (06) : 3050 - 3052
  • [7] Sensitive on-chip methane detection with a cryptophane-A cladded Mach-Zehnder interferometer
    Dullo, Firehun Tsige
    Lindecrantz, Susan
    Jagerska, Jana
    Hansen, Jorn H.
    Engqvist, Magnus
    Solbo, Stian Andre
    Helleso, Olav Gaute
    [J]. OPTICS EXPRESS, 2015, 23 (24): : 31564 - 31573
  • [8] Silicon nitride thermo-optic on-chip Mach-Zehnder interferometer at visible wavelengths
    Wang, Xiaomin
    Ji, Peirui
    Li, Shaobo
    Wang, Fei
    Deng, Huiwen
    Yang, Shuming
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2024, 35 (05)
  • [9] Design of an on-chip Fourier transform spectrometer based on waveguide Mach-Zehnder Interferometer and fluidics
    Li, Liang
    Qiao, Qifeng
    Zhou, Guangcan
    Qi, Yi
    Lim, Zi Heng
    Chau, Fook Siong
    Zhou, Guangya
    [J]. OPTICS COMMUNICATIONS, 2020, 460
  • [10] Photonic integrated Mach-Zehnder interferometer with an on-chip reference arm for optical coherence tomography
    Yurtsever, Gunay
    Povazay, Boris
    Alex, Aneesh
    Zabihian, Behrooz
    Drexler, Wolfgang
    Baets, Roel
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (04): : 1050 - 1061