Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements

被引:0
|
作者
Giorgio Ascenti
Achille Mileto
Bernhard Krauss
Michele Gaeta
Alfredo Blandino
Emanuele Scribano
Nicola Settineri
Silvio Mazziotti
机构
[1] Policlinico “G. Martino”,Department of Radiological Sciences
[2] Siemens AG,Dipartimento di Scienze Radiologiche
[3] Healthcare Sector,undefined
[4] Policlinico “G. Martino”,undefined
来源
European Radiology | 2013年 / 23卷
关键词
Dual-energy CT; Renal masses; Standard enhancement measurements; Iodine quantification; Diagnostic accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:2288 / 2295
页数:7
相关论文
共 50 条
  • [1] Distinguishing enhancing from nonenhancing renal masses with dual-source dual-energy CT: iodine quantification versus standard enhancement measurements
    Ascenti, Giorgio
    Mileto, Achille
    Krauss, Bernhard
    Gaeta, Michele
    Blandino, Alfredo
    Scribano, Emanuele
    Settineri, Nicola
    Mazziotti, Silvio
    EUROPEAN RADIOLOGY, 2013, 23 (08) : 2288 - 2295
  • [2] Dual-Source Dual-Energy CT Evaluation of Complex Cystic Renal Masses
    Ascenti, Giorgio
    Mazziotti, Silvio
    Mileto, Achille
    Racchiusa, Sergio
    Donato, Rocco
    Settineri, Nicola
    Gaeta, Michele
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 199 (05) : 1026 - 1034
  • [3] Comparison of Iodine Quantification and Conventional Attenuation Measurements for Differentiating Small, Truly Enhancing Renal Masses From High-Attenuation Nonenhancing Renal Lesions With Dual-Energy CT
    Mulligan, Margaret
    Budovec, Joseph J.
    Mautz, Alan
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 213 (01) : W37 - W37
  • [4] Distinguishing Enhancing From Nonenhancing Renal Lesions With Fast Kilovoltage-Switching Dual-Energy CT
    Kaza, Ravi K.
    Caoili, Elaine M.
    Cohan, Richard H.
    Platt, Joel F.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 197 (06) : 1375 - 1381
  • [5] Detection of left atrial appendage thrombi by third-generation dual-source dual-energy CT: Iodine concentration versus conventional enhancement measurements
    Li, Wenhuan
    Yu, Fangfang
    Zhu, Weiwei
    Zhang, Weiguo
    Jiang, Tao
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2019, 292 : 265 - 270
  • [6] Iodine Quantification With Dual-Energy CT: Phantom Study and Preliminary Experience With Renal Masses
    Chandarana, Hersh
    Megibow, Alec J.
    Cohen, Benjamin A.
    Srinivasan, Ramya
    Kim, Danny
    Leidecker, Christianne
    Macari, Michael
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2011, 196 (06) : W693 - W700
  • [7] Iodine quantification to distinguish hepatic neuroendocrine tumor metastasis from hepatocellular carcinoma at dual-source dual-energy liver CT
    Kaltenbach, Benjamin
    Wichmann, Julian L.
    Pfeifer, Sophia
    Albrecht, Moritz H.
    Booz, Christian
    Lenga, Lukas
    Hammerstingl, Renate
    Dangelo, Tommaso
    Vogl, Thomas J.
    Martin, Simon S.
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 20 - 24
  • [8] Dual-Energy and Dual-Source CT: Is There a Role in the Abdomen and Pelvis?
    Fletcher, Joel G.
    Takahashi, Naoki
    Hartman, Robert
    Guimaraes, Luis
    Huprich, James E.
    Hough, David M.
    Yu, Lifeng
    McCollough, Cynthia H.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2009, 47 (01) : 41 - +
  • [9] Abdominal dual-source dual-energy CT: Uses in clinical practice
    Siegel, Marilyn J.
    Ramirez-Giraldo, Juan Carlos
    Graser, Anno
    APPLIED RADIOLOGY, 2013, 42 (11) : 10 - 16
  • [10] Advantages of Dual-Source Dual-Energy CT for Radiation Therapy Planning
    Noid, G.
    Tai, A.
    Schott, D.
    Prah, D.
    Mistry, N.
    Robbins, J.
    Li, X.
    MEDICAL PHYSICS, 2018, 45 (06) : E129 - E130