Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery

被引:0
|
作者
Teppei Toya
Tomoyuki Fujita
Satuki Fukushima
Yusuke Shimahara
Yuta Kume
Kizuku Yamashita
Yorihiko Matsumoto
Naonori Kawamoto
Junjiro Kobayashi
机构
[1] National Cerebral and Cardiovascular Center,Department of Cardiac Surgery
来源
关键词
Near-infrared spectroscopy; Regional saturation of oxygen; Minimally invasive cardiac surgery; Lower limb ischemia;
D O I
暂无
中图分类号
学科分类号
摘要
Lower limb ischemia with an occlusive cannula is a potential complication of minimally invasive cardiac surgery (MICS). We evaluated intraoperative local oxygen supply–demand balance by monitoring regional saturation of oxygen (rSO2) using near-infrared spectroscopy (NIRS), and analyzed the correlation between cannula size and fluctuation range of rSO2. Fifty-four patients undergoing MICS surgery using femoral artery cannulation from April 2015 to August 2016 were enrolled. The rSO2 of both the cannulated and uncannulated lower limbs were measured using NIRS. The association between the decline of rSO2 from baseline (delta-rSO2) and the ratio of the cannula diameter to the femoral artery diameter (Cd/FAd) was analyzed. Of the 54 patients, 16 (30%) (Group 1) showed values over 0.65 for Cd/FAd, and the remaining 38 (70%) (Group 2) showed values under 0.65. No patient developed postoperative lower limb ischemia. No patient was treated with an ipsilateral distal perfusion cannula. There were significant differences between Group 1 and Group 2 in the decrease of rSO2 at the point of cannulation on the cannulated limb. In the lower limb on the cannulated side, delta-rSO2 showed a significant decrease in Group 1 compared to Group 2 (Group 1 vs Group 2: 19.9 vs 11.0%; p < 0.001). Delta-rSO2 was significantly correlated with body surface aera (BSA), but not with gender or age. Decreasing rSO2 correlates with the Cd/FAd index. Low BSA, Cd/Fad > 0.65 is considered as the risk factor for decline of rSO2 in cannulated limb in MICS.
引用
收藏
页码:420 / 426
页数:6
相关论文
共 50 条
  • [1] Efficacy of regional saturation of oxygen monitor using near-infrared spectroscopy for lower limb ischemia during minimally invasive cardiac surgery
    Toya, Teppei
    Fujita, Tomoyuki
    Fukushima, Satuki
    Shimahara, Yusuke
    Kume, Yuta
    Yamashita, Kizuku
    Matsumoto, Yorihiko
    Kawamoto, Naonori
    Kobayashi, Junjiro
    JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (04) : 420 - 426
  • [2] USE OF NEAR-INFRARED SPECTROSCOPY TO NONINVASIVELY MONITOR CEREBRAL REGIONAL OXYGEN-SATURATION
    CHEN, B
    BENNI, P
    OHARA, D
    AMORY, D
    STROKE, 1995, 26 (04) : 725 - 725
  • [3] Near-infrared spectroscopy monitoring tissue oxygen saturation after cardiac surgery
    R Kopp
    S Rex
    K Dommann
    G Schälte
    G Dohmen
    G Marx
    R Rossaint
    Critical Care, 13 (Suppl 1):
  • [4] Use of near-infrared spectroscopy to monitor regional cerebral oxygen saturation during infrarenal aortic crossclamping in piglets
    Ündar, A
    LeMaire, SA
    Schmittling, ZC
    Coselli, JS
    Köksoy, C
    Deady, BA
    Fraser, CD
    ARTIFICIAL ORGANS, 2003, 27 (09) : 849 - 853
  • [5] Regional oxygen saturation change rate for detection of leg ischemia in minimally invasive cardiac surgery
    Shikata, Fumiaki
    Nakamura, Yoshitsugu
    Okuzono, Yasuhito
    Uchigasaki, Yuichi
    Yamauchi, Naoya
    PERFUSION-UK, 2021, 36 (04): : 382 - 387
  • [6] The significance of regional hemoglobin oxygen saturation values and limb-to-arm ratios of near-infrared spectroscopy to detect critical limb ischemia
    Boezeman, Reinout P. E.
    Boersma, Doeke
    Wille, Jan
    Kelder, Johannes C.
    Visscher, Mareije I.
    Waanders, Frans G. J.
    Moll, Frans L.
    de Vries, Jean-Paul P. M.
    VASCULAR, 2016, 24 (05) : 492 - 500
  • [7] Monitoring of oxygen saturation by near-infrared spectroscopy and paediatric cardiac surgery: Not just for the brain!
    Mauriat, Philippe
    Tafer, Nadir
    Ouattara, Alexandre
    ANAESTHESIA CRITICAL CARE & PAIN MEDICINE, 2015, 34 (05) : 257 - 258
  • [8] CONTINUOUS MONITORING OF CEREBRAL REGIONAL OXYGEN-SATURATION DURING HYPERVENTILATION USING NEAR-INFRARED SPECTROSCOPY
    CHEN, B
    BENNI, P
    OHARA, D
    AMORY, D
    STROKE, 1995, 26 (04) : 725 - 725
  • [9] The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy
    Frederik Holmgaard
    Simon T. Vistisen
    Hanne B. Ravn
    Thomas W. L. Scheeren
    Journal of Clinical Monitoring and Computing, 2020, 34 : 245 - 251
  • [10] The response of a standardized fluid challenge during cardiac surgery on cerebral oxygen saturation measured with near-infrared spectroscopy
    Holmgaard, Frederik
    Vistisen, Simon T.
    Ravn, Hanne B.
    Scheeren, Thomas W. L.
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2020, 34 (02) : 245 - 251