Preliminary application of dynamic pulmonary xenon-133 single-photon emission tomography in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery

被引:0
|
作者
Kazuyoshi Suga
Kazuya Nishigauchi
Naofumi Matsunaga
Tsuneo Matsumoto
Norihiko Kume
Kazuro Sugi
Kensuke Esato
机构
[1] Department of Radiology,
[2] Yamaguchi University School of Medicine,undefined
[3] Ube,undefined
[4] Yamaguchi,undefined
[5] Japan,undefined
[6] First Department of Surgery,undefined
[7] Yamaguchi University School of Medicine,undefined
[8] Ube,undefined
[9] Yamaguchi,undefined
[10] Japan,undefined
来源
关键词
Key words: Single-photon emission tomography; Xenon-133 gas; Lung ventilation; Three-dimensional imaging; Lung volume reduction surgery;
D O I
暂无
中图分类号
学科分类号
摘要
Dynamic pulmonary xenon-133 single-photon emission tomography (SPET) with three-dimensional (3D) displays was preliminarily applied to select resection targets for thoracoscopic lung volume reduction surgery (LVRS) and to assess regional ventilatory changes following surgery. Dynamic SPET was performed using a triple-detector SPET system in 14 patients with pulmonary emphysema before and after LVRS. After reconstructing colour-illuminated, surface-rendered 3D images of equilibrium (EQ) and 3-min washout (WO3), a single 3D fusion display was created from these two different time-course image sets, in which the 3D WO3 image indicating 133Xe retention was visible through the overlying 3D EQ image delineating lung contours. Volumetric extent of retention on this display was quantified by a 133Xe retention index, defined as the ratio (%) of total pixel numbers of segmented 3-min WO data to those of EQ data. 133Xe SPET and appropriately thresholded 3D displays efficiently localized a total of 36 retention sites; 19 (52.7%) of these sites were not localized by CT because they were within the widely or homogeneously spreading non-bullous emphysematous lung tissues. The 3D displays enhanced the perception of anatomical configurations and the extent of 133Xe retention compared with multislice tomograms. Postoperatively, 3D fusion display visualized the details of regional changes in retention, and changes in the retention index on the 3D display with a standardized threshold correlated well with changes in 133Xe clearance time (T1/2) and %FEV1 (r = 0.881 and 0.856, respectively; P<0.0001). This preliminary study indicates that 133Xe SPET and appropriately thresholded, topographic 3D displays are of potential use in selecting resection targets for LVRS, and in evaluating the treatment effects on regional ventilation.
引用
收藏
页码:410 / 416
页数:6
相关论文
共 50 条
  • [1] Preliminary application of dynamic pulmonary xenon-133 single-photon emission tomography in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery
    Suga, K
    Nishigauchi, K
    Matsunaga, N
    Matsumoto, T
    Kume, N
    Sugi, K
    Esato, K
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE, 1998, 25 (04) : 410 - 416
  • [2] Three-dimensional dynamic pulmonary xenon-133 SPECT in the assessment of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery.
    Suga, K
    Nishigauchi, K
    Shimizu, K
    Kawamura, T
    Matsunaga, N
    Sugi, K
    Esato, K
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1253 - 1253
  • [3] Three-dimensional dynamic xenon-133 & Tc-99m-MAA SPECTs in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery
    Suga, K
    Nishigauchi, K
    Shimizu, K
    Kawakami, Y
    Sugi, K
    Esato, K
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 1251 - 1251
  • [4] Interactions of regional respiratory mechanics and pulmonary ventilatory impairment in pulmonary emphysema - Assessment with dynamic MRI and xenon-133 single-photon emission CT
    Suga, K
    Tsukuda, T
    Awaya, H
    Matsunaga, N
    Sugi, K
    Esato, K
    CHEST, 2000, 117 (06) : 1646 - 1655
  • [5] Three-dimensional dynamic xenon-133 SPECT in the evaluation of patients for thoracoscopic lung volume reduction surgery
    Suga, K
    Matsumoto, T
    Matsunaga, N
    Kume, N
    Sugi, K
    Esato, K
    RADIOLOGY, 1997, 205 : 351 - 351
  • [6] Thoracoscopic lung volume reduction surgery for pulmonary emphysema patients with severe hypercapnia
    Mitsui K.
    Kurokawa Y.
    Kaiwa Y.
    Ando K.
    Kurosawa H.
    Hida W.
    Satomi S.
    The Japanese Journal of Thoracic and Cardiovascular Surgery, 2001, 49 (8): : 481 - 488
  • [7] Radiologic evaluation of pulmonary emphysema and lung volume reduction surgery
    Chafin, SH
    Lupetin, AR
    Beckman, I
    Landreneau, RJ
    Isaacs, GH
    RADIOLOGY, 1996, 201 : 336 - 336
  • [8] Clinical evaluation of 99mTc-Technegas SPECT in thoracoscopic lung volume reduction surgery in patients with pulmonary emphysema
    Imai, T
    Sasaki, Y
    Shinkai, T
    Ohishi, H
    Nezu, K
    Nishimoto, Y
    Ichiba, N
    Yamane, T
    Yoshikawa, M
    Narita, N
    Uchida, H
    ANNALS OF NUCLEAR MEDICINE, 2000, 14 (04) : 263 - 269
  • [9] Clinical evaluation of99mTc-Technegas SPECT in thoracoscopic lung volume reduction surgery in patients with pulmonary emphysema
    Teruhiko Imai
    Yoshiaki Sasaki
    Takayuki Shinkai
    Hajime Ohishi
    Kunimoto Nezu
    Yuko Nishimoto
    Noriatsu Ichiba
    Tomohiko Yamane
    Masanori Yoshikawa
    Nobuhiro Narita
    Hideo Uchida
    Annals of Nuclear Medicine, 2000, 14 : 263 - 270
  • [10] Three-dimensional surface displays of perfusion SPET in the evaluation of patients with pulmonary emphysema for thoracoscopic lung volume reduction surgery
    Suga, K
    Nishigauchi, K
    Matsunaga, N
    Kawakami, Y
    Kume, N
    Sugi, K
    Esato, K
    NUCLEAR MEDICINE COMMUNICATIONS, 1997, 18 (08) : 719 - 727