Properties of a Non-Aromatic Epoxy Polymer-Based Monolithic Capillary Column for μ-HPLC

被引:0
|
作者
Ken Hosoya
Tomoko Mori
Mari Sakamoto
Takuya Kubo
Kunimitsu Kaya
机构
[1] Tohoku University,Graduate School of Environmental Studies
来源
Chromatographia | 2009年 / 70卷
关键词
Column liquid chromatography; Polymer monolith; Capillary column; Epoxy resin;
D O I
暂无
中图分类号
学科分类号
摘要
We report the chromatographic properties of a new type of epoxy polymer-based monolithic capillary column, the Tetrad-C column. The column was prepared by a completely new method—reaction of a tetra-functional epoxy monomer, 1,3-bis(N,N-diglycidylaminomethyl)cyclohexane (trade name Tetrad-C), with a diamine, 4-[(4-aminocyclohexyl)methyl)cyclohexane (BACM). This polymer monolith has no aromatic functional groups reducing chromatographic performance. The columns were carefully observed by scanning electron microscopy and evaluated chromatographically by use of a μ-HPLC system. It was found that morphological control of the epoxy polymer-based monolith was possible simply by changing the polymerization conditions, i.e., the polymerization temperature and/or the relative amounts of porogenic solvent and BACM. Another advantage was that volumetric shrinkage of the tetra-functional epoxy-based monolith during the polymerization reaction was much less than for the tri-functional epoxy-based monolithic (TEPIC) column reported in our previous paper. A Tetrad-C column 200 mm long afforded up to 10,000 plates for alkylbenzenes in reversed-phase-mode. This column can also work in HILIC mode, although the hydrophobicity of the column was greater than that of the TEPIC column. Heat treatment (160 °C for 2 h; to eliminate residual, unreacted, functional groups) had a negligible effect on column performance, indicating the columns were thermally stable.
引用
收藏
页码:699 / 704
页数:5
相关论文
共 50 条
  • [1] Properties of a Non-Aromatic Epoxy Polymer-Based Monolithic Capillary Column for μ-HPLC
    Hosoya, Ken
    Mori, Tomoko
    Sakamoto, Mari
    Kubo, Takuya
    Kaya, Kunimitsu
    CHROMATOGRAPHIA, 2009, 70 (5-6) : 699 - 704
  • [2] Cinnamic acid polymer-based monolithic column for capillary electrochromatography
    Weiying Yan
    Ruyu Gao
    Zhichao Zhang
    Chao Yan
    Qinsun Wang
    Chromatographia, 2003, 57 : 819 - 823
  • [3] High-performance polymer-based monolithic capillary column
    Hosoya, Ken
    Hira, Natsuki
    Yamamoto, Katsuya
    Nishimura, Masaru
    Tanaka, Nobuo
    ANALYTICAL CHEMISTRY, 2006, 78 (16) : 5729 - 5735
  • [4] Cinnamic acid polymer-based monolithic column for capillary electrochromatography
    Yan, WY
    Gao, RY
    Zhang, ZC
    Yan, C
    Wang, QS
    CHROMATOGRAPHIA, 2003, 57 (11-12) : 819 - 823
  • [5] Polymer-based monolithic capillary columns for proteomic.
    Xie, SF
    Jiang, T
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2005, 229 : U144 - U144
  • [6] Preparation of 4-aminopyridine imprinted polymer-based monolithic capillary column and evaluation of electrochromatography
    Yan, WY
    Zhang, ZC
    Gao, RY
    Wang, QS
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 2003, 24 (06): : 1026 - 1030
  • [7] Novel preparation of organic polymer-based monolithic column by microwave irradiation
    Xiong Wen Ye Yu Ping Zhang Ling Bo Qu Li Qun Fan Bo Li Department of Chemistry
    ChineseChemicalLetters, 2007, (11) : 1399 - 1402
  • [8] Novel preparation of organic polymer-based monolithic column by microwave irradiation
    Ye, Xiong Wen
    Zhang, Yu Ping
    Qu, Ling Bo
    Fan, Li Qun
    Li, Bo
    CHINESE CHEMICAL LETTERS, 2007, 18 (11) : 1399 - 1402
  • [9] Organic polymer-based monolithic capillary columns and their applications in food analysis
    Aydogan, Cemil
    Gokaltun, Aslihan
    Denizli, Adil
    El-Rassi, Ziad
    JOURNAL OF SEPARATION SCIENCE, 2019, 42 (05) : 962 - 979
  • [10] Characterization of polymer monolithic stationary phases for capillary HPLC
    Moravcová, D
    Jandera, P
    Urban, J
    Planeta, J